Iniciar sesión:
Votos - 5, Puntuación media: 3.4 ( )

Manual de usuario Roland, modelo GS-6

Fabricar: Roland
Tamaño del archivo: 1.23 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Otros manuales para este modelo:

Resumen del manual


An RJC message will be triggered when : • a WSD or RQD message has specified an illegal data address or size. ■ the device is not ready for communication. • an illegal number of addresses or data has been detected. • data transfer has been terminated by an operator. • a communications error has occurred. An ERR message may be sent out by a device on either side of the interface. Communication must be terminated immediately when either side triggers an ERR message. • Error occurs while device (A) is receiving data from device (B). 1) Data Transfer from device (A) u> device (B). Device (A) Device CB) [Data sat] [Acknowledge] - (Error) x [Communication error] [Data set] [Acknowledge] ~ [Date set] (the same data ‘ as above) Byte Description FOH Exclusive status 41H Manufacturer ID (Roland) DEV Device ID MDL Model ID 4FH Command ID F7H End of exclusive ¿Example of Message Transactions I Data transfer from device CA5 to device CB). Device (A) Device CB) [Want to send data] [DatB set] — [Date set] —■ [End of data] [Acknowledge] [Acknowledge] [Acknowledge] 2) Device CB) rejects the data re - transmitted, and quits data transfer. Device CA) Device (B) [Acknowledoe] —— (Error) x ^ [Communication error]* (Quit) [Data set] [Data set] [Rejection] 3) Device (A) immediately Quits data transfer. Device (A) [Acknowledge] (Error) x [Rejection] Device (B) [Data set] [Data set] (Quit) [Acknowledge] • DevicB (A) reouests and receives data from device (B). Device (A) Device (8) [Reouest data] [Acknowledge] [Acknowledge] [Acknowledge] [Data set] [Data set] [End of data] -37- Digital buitar bound bystern uate : иес. г.i iaoe Mode: GS-6 MIDI Implementation version : 1.00 GS-6 uses as the Basic channel the selected MIDI channel 1.TRANSMITTED DATA ■ Program Change Status Second CnH kkH n *= MID! channel : OH - FH (1-36) lek c Program number : 00H - 7FH (1 - 128) Program numbers 4OH - 7FH (65 — 128) can transmit, using Roland Foot Controller FC - 100. ■ System Exclusive Status FOH : System Exclusive F7H : EOX (End o! Exclusive) Transmitted when performing Bulk dump and receiving Data request (RQ1). Ref^r to Section 3 for details. ■ Active Sensing Status FEH 2.RECOGNIZED RECEIVE DATA Mode messages, except those on the Basic channel, are not recognized. ■ System Exclusive Status FOH : System Exclusive F7H : EOX (End of Exclusive) Used in the following three cases. 1) Receiving individual patch memory data 2) With MIDI messages, operating WRITE, CHORUS COPY, DELAY COPY and REVERB COPY 3) Operating Bulk load Refer to Section 3 for details. ■ Active Sensing Status FEH Having received this message, GS-6 expects to accept status or data in sequence, at least within 300 milliseconds intervals. If the unit falls to receive a message 300 milliseconds after the previous one. it judges there is a problem somewhere in Ihe MIDI patch, doing the maximum expression contra! (Genera! purpose controller I), ami cancelling mute control (General purpose controller 5), and stopping 300 milliseconds - interval monitoring of the incomming signal ■ Control Change General Purpose Controller 1 3.EXCLUSIVE COMMUNICATION Status BnH &£SQä юн Third vvH Model - ID sp in the exclusive message : 26H Device - ID if : Basic channel A less 1 ■ One - Way Communication n » MIDI channel number : OH - FH (1 - 16) Request data 1 RQ1 (11H) vv = Expression : ООН - 7FH (0 - 127) When RQ1 received contains a start address listed in Parameter Base Address and the When w is 7FH (127), it is ihe Master Volume value. size is the same, GS-6 sends the corresponding data using Data Set (DTI). When w is 0, Master Volume value is 0. The error checking process uses a checksum that provides a bit pattern where the This function is selected as ON or OFF. least significant 7 bits are 0 when values lor an address, size, and that checksum are summed. General Purpose Controller 5 Byte Description Status Second Third FOH Exclusive status BnH 50H vvH 4IH Roland ~ ID DEV Device - ID n * MIDI channel number : OH - FH (1 - 16) 26 H Model - ID ( GS - 6 ) vv * Mute OFF : 00H - 3FH (0 - 63) ПН Command - ID ( RQ1 ) vv = Mute OS' : 40H - 7FH (64 - 127) aaH Address MSB aaH Address LSB This function is selected as ON or OFF. ssH Size MSB ssH Size LSB ■ Program Change sum Checksum F7H EOX ( End of Exclusive ) Status Second CnH kkH Data set 1 DTI (12H) n = MIDI channel : OH - FH (1-16) kk “ Program number ; 00H - 7FH (î ~ 128) When the WRITE button is being pressed for over one second in MIDI mode. CS - 6 sends Bulk data using this message. Program number : Receivng 40H - 7FH (65 - 128), is equivalent to receiving 0DH - 3FH (1 - 6-1). The error checking process uses a checksum that provides a bit pattern where the least significant 7 bits are 0 when values lor an address, datas, and that checksum ■ Mode are summed. Omni Off Byte Description FOH Excl...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría