Iniciar sesión:
Votos - 1, Puntuación media: 5 ( )

Manual de usuario Roland, modelo MCB-1

Fabricar: Roland
Tamaño del archivo: 298.18 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment on and off, the user is encouraged to try to correct the interference by the following measure: « Disconnect other devices and their input/output cables one at a time. If the interference stops, it is caused by either the other device or its I/O cable. These devices usually require Roland designated shielded I/O cables. For Roland devices, you can obtain the proper shielded cable from your dealer. For non Roland devices, contact the manufacturer or dealer for assistance. If your equipment does cause interference to radio or television reception, you can try to correct the interference by using one or more of the following measures. • Turn the TV or radio antenna until the interference stops. • Move the equipment to one side or the other of the TV or radio • Move the equipment farther away from the TV or radio. • Plug the equipment into an outlet that is on a different circuit than the TV or radio. (That is, make certain the equipment and the radio or television set are on circuits controlled by different circuit breakers or fuses.) • Consider installing a rooftop television antenna with coaxial cable lead-in between the antenna and TV. If necessary, you should consult your dealer or an experienced radio/television technician for additional suggestions. You may find helpful the following booklet prepared by the Federal Communications Commission: "How to Identify and Resolve Radio — TV Interference Problems" This booklet is available from the U.S. Government Printing Office, Washington, D.C., 20402, Stock No. 004-000-00345-4. ■For Canada- CLASS B NOTICE This digital apparatus does not exceed the Class B limits for radio noise emissions set out in the Radio Interference Regulations of the Canadian Department of Communications. CLASSE B AVIS Cet appareil numérique ne dépasse pas les limites de la classe B au niveau des émissions de bruits radioélectriques fixés dans le Règlement des signaux parasites par le ministère canadien des Communications. Copyright ©1989 by ROLAND CORPORATION All rights reserved. No part of this publication may be reproduced in any form without the permission of ROLAND CORPORATION. M PANEL DESCRIPTIONS 3 SYNC OUT ©MIDI IN- (2j MIDI OUT 4 TAPE IN ©TAPE OUT "'I METRONOME OUT (DMIDI IN Connector Connector which receives MIDI data from a sequencer or keyboard instrument. The LAPC-I’s sound source can thus be sounded in accord with the performance of an external device. Also, depending on the type of sequencing software used on the computer, performance information can be input from an external device. (2)MIDI OUT Connectors Provide for transmission of the MIDI data generated by software used on the computer. Sequencing software can thus be used to play any sound modules that are connected externally. Also, the sequencing software can be used for synchronized performance along with a connected sequencer or rhythm machine. ©TAPE IN Jack Used for input of a FSK signal. Employed when wanting to synchronize play of computer software with a FSK signal recorded on a multi-track tape recorder. (DTAPE OUT Jack Used to output a FSK signal(signal synced to MIDI clock). Employed when wanting to record a FSK signal onto a multi-track tape recorder. ©METRONOME OUT Jack Allows for the output of a repetitive tone as a metronome, in time with the performance of computer sequencing software. Should the sound of this metronome be too faint to hear, connect a monitoring-use amplifier to this jack. (DSYNC OUT Connector(SYNC24) This connector transmits DIN Sync Signal(signal synced to MIDI clock). Allows for synchronized performance when using sequencing software and an external device equipped with DIN synchronization. ®D-Sub Connector Connector used to make connection with the LAPC-I. ■ CONNECTIONS •Connection with the LAPC-I Make connection between the D-Sub connector on the MCB-1 and the D-Sub on the LAPC-I installed in the computer. •MCEM System Setup Example MIDI Keyboard MIDI Sound Module Rhythm Machine D-IIÛ TR-707 IN SYNC IN MULTI TRACK RECORDER ■ SPECIFIC A TIONS Tarminal : MIDI IN *****..............»1 MIDI OUT.......*..........2 SYNC OUT **..............1 ■ TAPE IN ..................i TAPE OUT .........'*......I METRONOME OUT ******-I D-Sub CONNECTOR-......1 Dimensions ; I6§(W) X 50(D) X 6-l/2”Xl-l§/I6nX1474” Weight ; 410i/14o? (including the cable) * The sptoifioatlons for this product sr© lubjeet to ehnnge without prior notice, in the interest of improvement * m my time that you notice § malfunction, or otherwise gutpeet there it damage, Immediately refrain from using the unit- Then contact the itore where bought- Roland Corporation 2602098100 89-12-A3-13SY IHRoland® 2602098100 UPC 2602098100 Roland 10981...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría