Iniciar sesión:
Votos - 2, Puntuación media: 3.5 ( )

Manual de usuario Roland, modelo SP-202

Fabricar: Roland
Tamaño del archivo: 2.46 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Otros manuales para este modelo:

Resumen del manual


The REC button will go dark. 6. Press the BANK INT A/B button to make B light. 7. Press pad 3. 8. Press the MONO/STEREO button to make STEREO light. * Even if you sample with a setting of STEREO, the same sound will be recorded for both L and R if the input is monaural. In this case, the sound will be the same as if you had sampled using MONO, but it will use two notes of polyphony. 9. Start playback of the CD, and rotate the REC LEVEL knob to adjust the sampling level so that PEAK lights occasionally. When you finish making this adjustment, stop the CD player, and put it once again in play-standby mode. If you make the BPM (tempo) setting before you begin sampling, pressing the SAMPLING START/STOP button will cause the stop time (End Point) to automatically be set to a beat of the BPM value that was in effect before you pressed the button, and the MARK button will light. (Refer to page 27 "Playing only the desired portion of a sound") There are two ways to enter the BPM. If you already know the desired setting, you can enter it numerically. If not, press the TAP pad in time with the tempo (Tap input). 10-1 • To enter a numerical value, press the ▼ ▲ buttons to select the desired value. If you continue holding down a button, the value will increase or decrease continuously. 10-2. If you wish to use Tap Input, playback the CD, and press the TAP button in time with the beat. When you have pressed the button four times or more, the value will be input (displayed). ’ A tempo in the range of 40-200 can be specified. (When PITCH is OFF) 21 * You may reverse the order of steps 6-10, or make them as many times as desired. II.Start playback of the CD, and in synchronization with the beginning of the desired sound from the CD, press the SAMPLING START/STOP button. The REC button will light, and sampling will begin. * Never turn off the power while sampling is in progress. 12. When you wish to stop sampling, press the SAMPLING START/STOP button. Sampling will end, and the blinking pad will go dark. * The BPM will automatically be calculated and displayed according to the time length that was sampled. (If BPM was input, this will be the time between the Start and End points.) If the sampling time is two or more measures or is less than one measure, the BPM display value may be double or half the correct value. In this case, use the T ▲ buttons to set the desired value. (Refer to page 25 “Viewing and changing the BPM value after sampling") Please be aware that in some cases (such as triple meter), it may not be possible to calculate or adjust the BPM value accurately. * If you press the blinking pad (i.e., the one currently being sampled) instead of pressing the SAMPLING START/STOP button, sampling will end, and the currently-sampled sound will automatically be played back. 13. Press the pad (3) which went dark, and the sound that you just sampled will playback. * Once a sound has been sampled, it is not possible to change it from mono to stereo, or from stereo to mono. I Hi-Fi sampling / Long sampling (Sampling Grade) For each pad of the SP-202, you can specify one of four grades (Sampling Grades) at which the sample will be recorded. If getting a high-quality recording is more important than the length of the sample, select HI-FI (high sound quality). If sampling time is more important than the sound quality, select LO-FI 1 or 2. * For the possible sampling times at each grade, refer to page 24 "Sampling time / Checking the remaining time." In the following example, we will explain the procedure for selecting LO-FI 1 and recording a long sample. MUM fH BBS fpi-. HD S ® —ÓJSb.* 1—*1 ! i¿ ifllEB И 5,10,11 6,12 _ ,,m °wr • ШШШШВ ШШШШВ 8 3 3 1 1 T л ■ uuuu S3 ^ ■ BBg 1. Connect your CD player, (page 8,9) 2. Turn on the power of your CD player, and put the included CD in play-standby mode. 3. Set the SOURCE MIX switch to OFF, and the SOURCE SELECT switch to LINE. 4. Verify the settings you made in step 3, and turn the power switch ON. 5. Press the SAMPLING START/STOP button. The REC button will blink, and the SP-202 will enter standby mode. * If at this point you wish to stop sampling, press the CANCEL button. The REC button will go dark. 22 6. Press the BANK INT A/B button (or the CARD C/D button if you are using a memory card) and then pad to specify the bank and pad. The selected pad will blink. 7. Press the sampling grade setting button several times until LO-FI 1 lights. * A certain amount of time is required for the grade to be changed. It cannot be changed while the decimal points of the BPM display are blinking. Wait for the grade to change before you press the button again. * By selecting LO-FI 2, you can record even longer samples than with LO-FI 1. 8. Start playback of the CD, and rotate the REC LEVEL knob to adjust the sampling level so that PEAK lights occasionally. * Regardless of the sampling grade, the input sound will be heard without change when y...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría