Iniciar sesión:
Votos - 2, Puntuación media: 4 ( )

Manual de usuario Yamaha, modelo AI8

Fabricar: Yamaha
Tamaño del archivo: 150.6 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Otros manuales para este modelo:

Resumen del manual


The AI8 inputs signals to the DSP unit DSP1D/DSP1D-EX engine (controlled via the CS1D control surface). Up to ten AI8s can be connected to each DSP1D/DSP1D-EX. Be sure to ask an authorized Yamaha service engineer to install the card and set up the unit. Never perform installation and setup by yourself. Cards installable on the AI8 analog input box: • LMY2-ML, LMY2-MLAB, LMY4-MLF : MIC/LINE input card • LMY4-AD : AD card Up to eight cards can be installed. Unit models: • AI8-ML8AB : AI8 analog input box that has eight LMY2-MLAB cards installed • AI8-ML8F : AI8 analog input box that has eight LMY4-MLF cards installed • AI8-AD8 : AI8 analog input box that has eight LMY4-AD cards installed ¦ Front panel UNIT NO. PHANTOM MASTER ON OFF +48V POWER ON/ OFF 1 2 3 4 5 6 7 8 ANALOG INPUT BOX 1 2 3 INPUT UNIT ID PHANTOM MASTER ON OFF +48V POWER ON/ OFF ANALOG INPUT BOX * * The illustration shows the AI8 analog input box. ¦ Rear panel 75.IN C B A OUTPUT ON OFF OUT A B C CONTROL PORT WORD CLOCK 75.IN C B A OUTPUT ON OFF OUT A B C CONTROL PORT WORD CLOCK 5 4 6 7 5 A INPUT UNIT ID indicator This indicator displays the ID number of the INPUT connector of the DSP unit DSP1D/DSP1D-EX connected to the AI8. If an error occurs in the connection to the DSP1D, or if the unit does not lock to the wordclock signal, one of the following error indications appears. Error message E1 : The AI8 is connected to the OUTPUT connector of the DSP1D/DSP1D-EX. Connect the AI8 to the INPUT connector. E3 : A cable is disconnected from the OUTPUT A, B, or C connector on the rear panel, or the connection is made incorrectly. If the connection is proper, replace the cable. UL : The unit does not lock to the wordclock signal. UC : The control signal is not being received correctly. “ . x . ”:(two dots and the ID number of the OUTPUT connector on the DSP1D/DSP1D-EX) Illuminating or flashing dots mean that the AI8 is connected in Mirror mode from the DSP1D/ DSP1D-EX. If “ . x . ” lights up continuously during Mirror mode operation, the CONTROL PORT switch ( 4 ) setting matches the setting controlled from the CS1D and the system is operating normally. If the control signal from the CS1D has changed the setting during Mirror mode operation and it does not match the CONTROL INPUT PORT switch ( 4 ) setting any more, this indicator changes in the following order. “ ” means that the control signal from the CS1D has changed the setting to “A.” “ ” means that the control signal from the CS1D has changed the setting to “B.” During this time period, you can connect or disconnect the cable from the unselected output connector. If you set the CONTROL PORT switch so that it matches the setting made via the control signal from the CS1D, “ . x . ” lights up continuously. B PHANTOM MASTER switch, indicator This switch is used to turn the phantom power on and off to all the headphone amplifiers of the input connectors (for which the phantom power is switched on) on the AI8 that has the analog input card (LMY2- MLAB etc.) equipped with the headphone amplifier. When you turn on the switch, the indicator on the left of the switch lights up. C POWER ON/OFF Use this switch to turn the power to the AI8 on and off. When the power is turned on, the INPUT UNIT ID indicator lights up. D CONTROL PORT switch This switch enables you to select a port used to control the AI8 via the DSP unit DSP1D/DSP1D-EX. Select from OUTPUT A, B, and C to receive the control signal for switching between channels A and B on the analog input card (LMY2-MLAB etc.), or turning the phantom power on and off. During Mirror mode operation, the control signal sent from the CS1D has priority, and the CONTROL PORT switch is disabled. In this case, the INPUT UNIT ID indicator shows the status. For more information, refer to 1 INPUT UNIT ID indicator. E OUTPUT connectors A, B, C These connectors are used to output multi-channel digital audio signals. The same signal is routed to all three connectors. Be sure to use the included genuine Yamaha half-pitch 68-pin cable for connection. Optional genuine Yamaha cables in a variety of lengths are also available. F WORD CLOCK IN jack, ON/OFF switch The WORD CLOCK IN jack is used to provide the word clock to the AI8 from a connected external device or a clock generator. Use a BNC cable with an impedance of 75 . for connection. The WORD CLOCK ON/OFF switch is used to terminate the word clock connection. Basically, if the AI8 is the last device of the word clock chain, or if nothing is connected to the WORD CLOCK IN/OUT jacks, set this switch to ON. G WORD CLOCK OUT jack The WORD CLOCK OUT jac...

Otros modelos de este manual:
Instrumentos Musicales - AI8-AD8 (150.6 kb)
Instrumentos Musicales - AI8-ML8AB (150.6 kb)
Instrumentos Musicales - AI8-MLF (150.6 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría