|
Otros manuales para este modelo:
Resumen del manual
Table of Contents ¦ Main changes.....................................2 ¦ Other changes..................................10 Auto Gain Adjustment function......................2 Filtering during save or load operations ........10 PM1D Manager Remote Control function......2 Direct output just before the HPF................11 VCM Effects available .....................................3 Additional functions for the USER DEFINE Channel Move function in the CH COPY switches ................................................... 11 screen.........................................................3 Inserting MIDI events from the event list.....12 CLEAR ALL button added to the OSCILLATOR ¦ Changes in Scene Memories and and TALKBACK screens............................. 13 Libraries.............................................. 5 Outputting the MONITOR and CUE signals from the DSP1D ....................................... 13 Expanding the Event Recall function No limitation in multiple selections for the in the TC EVENT screen...............................5 Global Paste function ............................... 14 Overwriting libraries during the Auto Store Selecting WITH MIX SEND in the CH COPY operation ....................................................6 screen ...................................................... 14 Unit settings can be included in the Recall Support for the MY8-DA96 card .................. 14 Safe channel settings...................................7 Compatibility of created data ...................... 14 Additional preset scenes.................................7 Expanded user area for Input EQ/Channel ¦ Appendix .......................................... 15 libraries .......................................................7 Scene Memory Preset List............................ 15 ¦ Changes and additions of screens.....8 VCM Effect Parameter List............................ 18 New FADER VIEW screen................................8 Clock on the meter bridge .............................8 Displaying the GEQ routings..........................8 Displaying the GR meters...............................9 EN Main changes Auto Gain Adjustment function If you adjust the HA gain on the master CS1D (master for HA control), the attenuation on a slave CS1D can automatically be adjusted so that the channel output levels will remain unchanged. Engine DSP1D/ Slave DSP1D-EX Console CS1D A B C CONTROL PORT ANALOG OUTPUT BOX Output B Output A Engine DSP1D/ DSP1D-EX AI8 (ID=1) Master Console CS1D The master unit is the CS1D (or PM1D Manager) connected via a DSP1D that is connected to the port through which the AI8 is controlled. The slave unit is the CS1D (or PM1D Manager) connected via a DSP1D that is connected to any port other than the master. You can switch between the master and slave. ¦ Switching the Auto Gain Adjustment function on and off 1. On the slave CS1D, display the ATT screen for the IN EQ function. AUTO GAIN ADJUSTMENT button ATT SET ALL and CLEAR ALL buttons GAIN ADJ buttons 2. In the upper left of the screen, click the AUTO GAIN ADJUSTMENT button to enable the function. The Auto Gain Adjustment function is now enabled. 3. Turn the GAIN ADJ button on or off to switch the function for each channel on or off. Note • Click the SET ALL button to turn on the function for all channels globally. Click the CLEAR ALL button to turn off the function for all channels globally. • In most cases, turn on the Auto Gain Adjustment function only on the slave CS1D unit. If you turn on the function on the master CS1D unit, the output level of the master CS1D will also be adjusted automatically. • The GAIN ADJ button’s on/off status is not linked even if the corresponding two channels are paired. Even if the GAIN ADJ button of either one of the paired channels is turned on, the attenuators will not be linked. • When you turn off the GAIN ADJ button for one of the paired channels, the attenuator value for the even-numbered channel will change to the value for the odd-numbered channel. In this case, please note that the volume level might increase more than expected. • If the attenuator values are selected as one of the Recall Safe items, and if the GAIN ADJ button for the recalled scene is set to on, this function will apply to the recalled HA gain. The Recall Safe function does not apply to the GAIN ADJ button and AUTO GAIN ADJUSTMENT button settings. Therefore, you must first store these button settings in the scenes. PM1D Manager Remote Control function Connecting the PM1D Manager and a Yamaha digital mixing console (DM2000, 02R96, or DM1000) via USB enables you to remotely control the PM1D system from the digital mixing console. For details, refer to the PM1D Manager V2 Owner's Manual. Yamaha digital mixer (DM2000 V2, 02R96 V2, PM1D Manager DM1000 V2) Console CS1D Engine DSP1D/DSP1D-EX USB USB/RS232C PM1D system 2 Main changes VCM Effects available VCM Effects available EFFECT The VCM effects employ Virtual Circuitry Modelin...