Iniciar sesión:
Votos - 2, Puntuación media: 5 ( )

Manual de usuario dbx Pro, modelo 160A

Fabricar: dbx Pro
Tamaño del archivo: 226.72 kb
Nombre del archivo: 160a_manual.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Operation is subject to the following two conditions: . this device may not cause harmful interference, and . this device must accept any interference received, including interference that may cause undesired operation. Operation of this unit within significant electromagnetic fields should be avoided. . use only shielded interconnecting cables. DECLARATION OF CONFORMITY ManufacturerOs Name: dbx Professional Products ManufacturerOs Address: 8760 S. Sandy Parkway Sandy, Utah 84070, USA declares that the product: dbx 160A conforms to the following Product Specifications: Safety: EN 60065 (1993) IEC65 (1985) with Amendments 1, 2, 3 EMC: EN 55013 (1990) EN 55020 (1991) Supplementary Information: The product herewith complies with the requirements of the Low Voltage Directive 73/23/EEC and the EMC Directive 89/336/EEC as amended by Directive 93/68/EEC. dbx Professional Products Vice-President of Engineering 8760 S. Sandy Parkway Sandy, Utah 84070, USA July 28, 1998 European Contact: Your Local dbx Sales and Service Office or International Sales Office 68 Sheila Lane Valparaiso, Indiana 46383, USA Tel: (219) 462-0938 Fax: (219) 462-4596 dbx 160A COMPRESSOR / LIMITER MANUAL CONTENTS QUICK SET-UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 INSPECTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 APPLICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 OPERATING CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 OPERATING NOTES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 CONNECTING THE 160A TO YOUR SYSTEM . . . . . . . . . . . . . . . . . . . . . . 10 INSTALLATION CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 TECHNICAL SUPPORT / FACTORY SERVICE . . . . . . . . . . . . . . . . . . . . . . 13 WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 dbx 160A COMPRESSOR / LIMITER ® PROFESSIONAL PRODUCTS QUICK SETUP To get your unit up and running as quickly as possible, do the following steps. For more detailed information, refer to the specified pages. . Unpack and Inspect the 160A Package. . Set Levels and Controls as Needed. . Connect the 160A to Your System. INSPECTION Verify that the 160A package contains the following: . 160A Unit . AC Power Cord . Operation Manual (including Registration Card) INTRODUCTION Congratulations on purchasing the dbx 160A Compressor/Limiter. We recommend you take a moment and read through the manual as it provides information that will assist you from system installation to operation to special applications. Features include: . OverEasy./Hard Knee Selection -- allows selection between our famous OverEasy compression curve and the classic OHard KneeO curve popularized by the original dbx 160, 161 and 162. . True RMS Level Detection™ --senses the power in the program in a musical manner, much as the ear does, giving results superior to peak or average detection. . Hardwire System Bypass Button --allows the audio to pass even if the unit is unplugged, and is also useful for comparing the processed and unprocessed signal. . Front Panel SLAVE Button --couples two 160As together for stereo operation at the push of a button. Note: a 160A unit cannot be stereo-coupled with a dbx 160XT, 160X, 160, 161 or 162 unit. . True Power Summing --When two 160A units are slaved together, the RMS energy of the signal presented to the slave unit is summed with the RMS energy of the signal presented to the master unit to prevent phase cancellation of the two signals from causing unmusical compressor action. . LED Displays --19-Segment LED Display for high resolution monitoring of True RMS INPUT and OUTPUT LEVELs; 12-Segment LED Display for GAIN REDUCTION (up to 40dB). . Meter Calibration --Input/Output meter calibration, so the 160A can be used in a variety of situations where the O0O reference is not consistent. . XLR-type Input and Output Jacks --because the 3-pin XLR connector has been recognized as the most durable and widely used connector for professional applications. (An optional output transformer is available.) . Input and Output Jacks --with the output capable of driving its own additional 600. load (single-ended) in addition to any load on the XLR output. . Input Ground Lift Switch --internally disconnects pin 1 of the input XLR jack from 160A chassis ground to eliminate any ground loop hum problems that may arise. . Detector Input --useful for special applications including frequency conscious compression in which an external equalizer is used. . DC-controlled Parameters --the signal does not pass thro...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría