Iniciar sesión:
Votos - 3, Puntuación media: 4.3 ( )

Manual de usuario AC International, modelo 8200 Series

Fabricar: AC International
Tamaño del archivo: 1.06 mb
Nombre del archivo: a0651d87-4407-45e3-b866-78cc90cb4a9a.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


TABLE OF CONTENTS DESCRIPTION......................................................3 OPERATIONAL LIMITS .......................................3 MAXIMUM WORKING PRESSURE.....................3 SEAL OPERATING LIMITS .................................3 PACKING ......................................................3 PUMP IDENTIFICATION ......................................3 SAFETY INSTRUCTIONS ....................................4 ADDITIONAL SAFETY REQUIREMENTS:...4 ADDITIONAL SAFETY REQUIREMENTS:..........5 ELECTRICAL SAFETY: ................................5 THERMAL SAFETY: .....................................5 MECHANICAL SAFETY:...............................5 INSTALLATION....................................................6 PUMP LOCATION.........................................6 RECEIVING PUMP .......................................6 TEMPORARY STORAGE .............................7 LOCATION ....................................................7 FOUNDATION...............................................7 BASE PLATE SETTING (BEFORE PIPING) 8 GROUTING PROCEDURE ...........................8 SEE ANSI/OSHA COUPLER GUARD REMOVAL/INSTALLATION ..................8 ALIGNMENT PROCEDURE .........................8 ANSI/OSHA COUPLER GUARD REMOVAL/INSTALLATION ..................9 DOWELING.................................................11 SUCTION AND DISCHARGE PIPING........11 STUFFING BOX LUBRICATION.................14 PACKING ....................................................14 OPERATION.......................................................16 PRE-START CHECKS ................................16 PRIMING .....................................................16 STARTING ..................................................16 OPERATING CHECKS ...............................16 FREEZING PROTECTION..........................17 FIELD TESTING..........................................17 MAINTENANCE..................................................17 GENERAL MAINTENANCE ........................17 MAINTENANCE OF PUMP DUE TO FLOOD DAMAGE .............................................17 BEARING LUBRICATION – GREASE........18 PACKING SEAL ..........................................18 CLEANING WITHOUT DISMANTLING PUMP ..................................................18 MAINTENANCE TIME TABLE........................... 19 TROUBLE SHOOTING ...................................... 20 CHANGING ROTATION .................................... 23 SERVICE INSTRUCTIONS ................................ 24 DISASSEMBLY AND REASSEMBLY PROCEDURES................................... 24 DISMANTLING (PUMP WITH PACKING) .. 24 ASSEMBLY (PUMP WITH PACKING) ....... 27 APPENDIX “A” ENGINEERING DATA.............30 APPENDIX “B” .................................................. 31 EXPLODED VIEW – 8200 SERIES FIRE PUMP.................................................. 31 REPLACEMENT PARTS LIST ................... 32 INSTRUCTIONS FOR ORDERING PARTS33 APPENDIX “C” FIELD TEST REPORT ............ 34 USEFUL FORMULAS.................................35 NOTE The information contained in this book is intended to assist operating personnel by providing information on the characteristics of the purchased equipment. It does not relieve the user of their responsibility of using accepted engineering practices in the installation, operation, and maintenance of this equipment. Any further questions, contact ITT A-C Pump, (847) 966-3700. 2 DESCRIPTION The 8200 Series Centrifugal Fire Pumps are framed mounted pumps which feature – high efficiency, rugged construction, compact design, foot mounted volute and regreasable bearings. These features, along with the horizontal split case, make installation, operation and service easy to perform. OPERATIONAL LIMITS Unless special provisions have been made for your pump by ITT A-C Fire Pump Systems, the operational limits for 8200 Series Centrifugal Fire Pumps are as follows: MAXIMUM WORKING PRESSURE Listed on pump nameplate. SEAL OPERATING LIMITS PACKING PH Limitations 7-9; Temperature Range 0 to +200°F For use on open or closed systems which require a large amount of makeup water, as well as systems which are subjected to widely varying chemical conditions and solids buildup. PUMP IDENTIFICATION There are two identification plates on each pump. The pump rating plate gives identification and rating information. Figure 1 shows an example of a typical Rating Plate. Permanent records for this pump are referenced by the Serial Number and it must, therefore, be used with all correspondence to order all spare parts and replacement parts. The fourth digit indicates the specific pump on orders for more than one pump. For example, if an order called for six pumps, all pumps would have the same first three sets of digits and the last digit will change to identify each of the six. (e.g. 03-123456-0101, 03-123456-01-02, etc.) The frame plate, shown below in Figure 2, gives information concerning the bearings and their lubrication. The inboard and outboard be...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría