Resumen del manual
• In continuous mode, the fan runs continuously and the symbol is displayed. NOTE: If the “smart fan” feature is enabled, the fan will run only when heating or cooling will be activated during unoccupied mode. 6. Temperature Setting 6.1 Display Appears when the temperature setpoint is displayed Indoor temperature Heating is On Cooling is On System operating mode Auxiliary heating is On Temperature adjustment mode (appears when the Fan operating mode controller is in automatic (appears when the fan mode, disappears when it is in continuous mode, is in manual mode) disappears when it is in automatic mode) The controller normally displays the measured indoor temperature. To view the setpoint, press one of the buttons. The setpoint will be displayed along with the symbol for the next 5 seconds. 6.2 System Operating Mode Press Mode to place the system in one of the following modes: HEAT The system is in heating mode. COOL The system is in cooling mode. The system is in automatic changeover. (The system AUTO switches between heating mode and cooling mode to maintain the desired temperature.) OFF Both heating or cooling are off. The system is in emergency heat mode. Only auxiliary EHEAT heating is used when there is a call for heat. TH146-P-DE 400-280-004-C 11/29/06 7/9 6.3 Temperature Adjustment 6.3.1 Manual Adjustment Use this adjustment mode to set the temperature manually. To place the controller in this mode, press Auto/Man so that disappears from the screen and set the temperature using the buttons. NOTE: If the controller is in automatic heat/cool changeover, the setpoint is automatically lowered or raised by 1°C (2°F) when the controller switches to heating mode or to cooling mode respectively. For example, if you place the setpoint at 24°C (75°F) while in heating mode, the setpoint will become 25°C (77°F) in cooling mode and will return to 24°C (75°F) when the controller switches back to heating mode. 6.3.2 Automatic Adjustment Use this adjustment mode if you want the controller to automatically adjust the temperature according to the programmed schedule. To place the controller in this mode, press Auto/Man so that appears on the screen. Pre-programmed Schedule The following schedule has been programmed at the factory. Two temperature settings are programmed for each period of the schedule: one is used in heating mode and the other in cooling mode. NOTE: When programming the heating setpoint, it cannot be higher than 1°C (2°F) below the cooling setpoint. For example, if the cooling setpoint is 25°C (77°F), the highest you can place the heating setpoint is 24°C (75°F). Conversely, when programming the cooling setpoint, it cannot be lower than 1°C (2°F) above than the heating setpoint. Pre-programmed Schedule MO TU WE TH FR SA SU P1 Heating 21°C (70°F) 6:00 a.m. Cooling 25.5°C (78°F) P2 Heating 16.5°C (62°F) 8:00 a.m. -Cooling 29.5°C (85°F) P3 Heating 21°C (70°F) 6:00 p.m. -Cooling 25.5°C (78°F) P4 Heating 16.5°C (62°F) 10:00 p.m. Cooling 28°C (82°F) Modifying the Schedule You can program up to 4 periods per day. For each period, you can set the start time, the heating mode setpoint and the cooling mode setpoint. The program can be different for each day of the week. • Press Pgm to enter the programming mode. The settings for Monday, Period 1 (P1) appear. • To select a day to program, press Day until the day is displayed. Press Day for 3 seconds to select all 7 days. NOTE: If you select all 7 days, the settings of the displayed period will be copied to all 7 days. For example, if period 1 is displayed and you then select all 7 days , they will all now have the same settings for period 1. If you display period 2 while all 7 days are selected, they will all now have the same settings for period 2. • To set the start time of a period, first press Pgm until the period number (P1 to P4) is displayed and the time display flashes. Then press the buttons. The time changes in increments of 15 minutes. NOTE: During programming, to skip a period press Clr while the period is selected. For example, in the pre-programmed schedule, periods 2 and 3 have been skipped for Saturday and Sunday. • To set the temperature for a period, first press Pgm until the period number (P1 to P4) is displayed and the temperature display flashes. Then press Mode to select the heating mode set- point display or the cooling mode setpoint. Finally press the buttons. • Press to exit. The following diagram shows how to navigate the programming menu. Temporary Bypass When you modify the temperature setpoint while the controller is in automatic mode, the new temperature is used for the next 2 hours. The icon flashes during the bypass. After the bypass, the temperature set for the current period is used. MOTUP1P16:006:002125.52125.5MOTUP2P28:008:0016.529.516.529.5Pgm Pgm Pgm Pgm Pgm Pgm Day Day Mode Mode Mode Mode Heat Cool Heat Cool Heat Cool Heat Cool 6.4 Unoccupied Mode The controller can be placed in unoccupied mode via a remote control device ...