NEVER attempt torepair or modify a tank! Welding, drilling or any other modification will weaken the tank resulting in damage from rupture or explosion. Always replace worn, cracked or damaged tanks. 3. Clean electrical equipment with an approved cleaning agent, such as a dry, non-flammable cleaning solvent. Daily Check oil level at sight glass. Drain moisture from tank. Verify the pressure switch unloader is working by listening for a brief hissing sound when the compressor shuts off. V_sually check the compressor for loose parts, excessive noise or vibration. , Drain tanks of moisture after each day's use. If unit will not be used for awhile, it is best leave drain cock open until such time as it is to be used. This will allow moisture to completely drain out and help prevent corrosion of inside of tank. . Always disconnect from power source before working on or near a motor, or its connected load. If power disconnect point is out-ofsight, secure it in the =OFF" position and tag it to prevent unexpected application of power. Disconnect power and depressurize system before servicing air compressor. Slightly open drain cock after shutting off compressor. Monthly (Make sure the main power is off). Check the belts for tension. Belts should not move up and down when the compressor runs and when stopped, should not have more than . in of play when depressed. Be careful not to over tighten belts during adjustment. Remove and check air filter, replace if necessary. Change oil every 3 months or 300 hours. A compressor grade non-detergent oil should be used. (40 wt for K7060V/K7060HFV and 30wt for K758OV2). Page 4 Find and read all warning labels found on the air compressor. r7i. Air Filter Porous element contained within a metal or plastic housing attached to the compressor cylinder head which removes impurity from the intake air of the compressor. Air Tank Cylindrical component which contains the compressed air. Check Valve Device which prevents compressed air from flowing back from the air tank to the compres sor pump. Electric Motor Device which provides the rotational force necessary to operate the compressor pump. Pressure Gauge Device which shows the tank or regulated pressure of the compressed air. Pressure Switch Device which automatically controls the on/off cycling of the compressor. It stops the compressor when the cut-off pressure in the tank is reached and starts the compressor when the air pressure drops below the cut-in pressure. PSI (Pounds per Square Inch) Measurement of the pressure exerted by the force of air. The actual psi is measured by a pressure gauge on the compressor Pump Device which produces the compressed air with a reciprocating piston contained within a cylinder Safety Valve Device which prevents air pressure in the air tank from rising over a predetermined limit. Thermal Overload Switch Device, integrated into the electric motor winding, which automatically =shuts ofT'the compressor if the temperature of the electric motor exceeds a predetermined limit. Page 5 A vlvl,,1:i _II_[,e ALL ELECTRICAL WIRING SHOULD BE DONE BY A QUALIFIED ELECTRICIAN General Information Adequate wiring and motor protection should be provided for all stationary compressors. Wiring used for other machinery should not be used. A qualified electrician familiar with local electrical codes in your area should be used. To reduce the risk of electrical hazards, fire hazards or damage to the compressor, use proper circuit protection. Your compressor is wired at the factory for operation using the voltage shown. Connect the compressor to a power source with the correct breaker size. Electrical connections must be propedy grounded. Ground connections should be connected at the grounding screw. il;lll I [I] _ ,4, Overheating, short circuiting and fire damage will result from inadequate wiring. Incoming power should be connected to the posts marked (line) Do Not Make Connections On Prewired Posts (Motor)! Grounding Screw K7060V K7580V2 K7060HFV Voltage 230V / 1 ph 230V / 1 ph FLA 16 23 Breaker Size 30 amp 40 amp The motor is equipped with a manual, resetable ovedoad device to protect it from overheating. In the event the compressor will not run and power is properly connected and on, press the motor ovedoad reset button located on the non drive end of the motor. Prior to actually running the compressor, check the following items: Crankcase oil -Make sure the sight glass shows . full or slightly above. Make sure all rags, tools, oil, etc. are away from the unit. Open the air system to free it of any pressure. Switch the compressor onfor afew revolutions to make sure the rotation is correct. Correct rotation is clockwise when facing the sight glass on the pump. Operate the compressor for a few minutes unloaded (air system open) then allow the compressor to pump up. Make sure the electdcal pressure switch propedy switches off the compressor according to the setting desired. (135 psi for K7060V/K7060HFV and 175 psi for K758...

Otros modelos de este manual:
Equipos de Bombeo - K7060HFV (541.57 kb)
Equipos de Bombeo - K7580V2 (541.57 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría