Iniciar sesión:
Votos - 4, Puntuación media: 4 ( )

Manual de usuario Aquacal, modelo 156

Fabricar: Aquacal
Tamaño del archivo: 271.13 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Otros manuales para este modelo:

Resumen del manual


EQUIPMENT CLEARANCES Keep the area immediately adjacent to the heat pump clear of items such as shrubs and bushes, lawn furniture, chemicals containers, etc. These items can prevent air from circulating properly through the heater, and will result in inefficient operation and/or damage to the heat pump. Figure 1 Figure 2 Overhang with Gutter 5 feet Minimum Clearance Overhead Rain Run-Off Must Be Directed Away From Heater (Front) 30” Minimum Clearance (Rear) 12” Clearance for all IceBreaker / Heat & Cool Models 12” Clearance for All Tropical Models 6” Clearance for SQ “Heat Only” Models (Rear) 12” Clearance for All IceBreaker / Heat & Cool Models 12” Clearance for All TropiCal Models 6” Clearance for SQ “Heat Only” Models (Side) 12” (Side) 12” (Front) 30” PLUMBING SCHEMATIC 3 = Three-Way Valve B = Bypass Check Valve (5lb) for Water Flow Over Max Flow (see Specifications for details) C = Chlorinator D = Main Drain F = Filter H = Heat Pump P = Water Pump R = Return S = Skimmer Figure 3 F P 3 S D POOL R C B H ELECTRICAL REQUIREMENTS 1) Locate the equipment power disconnect within 6-feet of the heater’s electrical enclosure. 2) Never mount power disconnects directly to heat pump. 3) Only use copper conductors. 4) Use sequencing controllers when multiple heaters are installed on site. 5) Local codes and regulations may require the use of a ground fault interruption device (GFI Circuit Breaker). Nuisance tripping of these devices is common and not covered under the terms of the Manufacturer’s warranty. 6) Review online product manual when connecting external controller devices to heat pump. SECTION 3 - OPERATION Figure 4 Desired Temp Water Temp Heating MODE DOWN UP Pool Spa Cooling 78° POOL SPA INDICATOR LIGHTS LIGHTS EXPLANATION SUPPLEMENTAL INFORMATION “Pool” Pool Thermostat Selected “Spa” Spa Thermostat Selected “Cooling” Actively Cooling Water Not applicable for Straight Heat models. “Desired Temp” Setting Desired Water Temperature “Water Temp” Actual Water Temperature “Heating” Actively Heating Water Table 3 BUTTONS BUTTONS EXPLANATION SUPPLEMENTAL INFORMATION “Pool / Spa” Select between Pool and Spa Please note – this does not turn off equipment. It only allows a user to toggle between the Pool thermostat and the Spa thermostat. “Up” Select to raise temperature set point or move up in a menu choice “Down” Select to lower temperature set point or move down in a menu choice “Mode” Select a mode Modes available are “ACH”, “COOL”, “HEAT”, and “OFF”. Please note – “ACH” and “COOL” only available on some models. Table 4 DISPLAY MESSAGE EXPLANATION SUPPLEMENTAL INFORMATION “000” A user lockout code has been activated. A numeric code is required before any temperature adjustment can be entered. Use the “UP” or “DOWN” arrow to enter code, then select “MODE” to temporarily unlock Heat Pump. If code is unknown, a re- set option is available in product manual. Manuals can be downloaded from “ACH” Auto-Change Over Mode When this mode is active...

Otros modelos de este manual:
Equipos de Bombeo - 110 (271.13 kb)
Equipos de Bombeo - 121 (271.13 kb)
Equipos de Bombeo - 175 (271.13 kb)
Equipos de Bombeo - 55 (271.13 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría