Manual de usuario Elektra Beckum, modelo Cool 401

Fabricar: Elektra Beckum
Tamaño del archivo: 580.17 kb
Nombre del archivo: 2b56c848-badd-4021-a1bc-448ff1727901.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


If the condensate volume deviates from the set values (see 4.6.1.6) the adaptation to the specific characteristics of compressed air system is possible (see 4.6.1.6) Once the container has filled with condensate, so that the capacitive level sensor emits a signal, the internal solenoid valve opens and the condensate is forced by the working pressure into the discharge pipe. The condensate drain electronic system ensures the closing of the outlet opening before any compressed air can escape. For functional safety a minimum pressure of 2 bar is necessary. 1 2 3 Alarm Test Power Alarm Test Power Alarm Test At faulty condensate discharge (blocked discharge pipe, pressure below minimum operating pressure), the unit changes to the alarm control after 60 seconds.The green LED flashes and a potential-free contact is activated. While in alarm control mode, the solenoid valve will open every 4 minutes for a period of 7,5 seconds, in order to remove any possible obstructions in the discharge pipe automatically. A unit filled during a pressureless state will additionally be emptied automatically, as soon as the minimum pressure within the condensate drain has been reached. 16 11.02 Part 4 Operation Part 4 Operation 4.1 Commissioning 4.2 Starting 4.3 Operation 4.4 Stopping After installation the CA-dryer is supplied with power via the power cable (fig. 5/1) or by operating the main switch (fig. 5/13). Before operating the operation switch (fig. 3/14), a waiting period of at least 6 hours is absolutely necessary. The CA-dryer is switched on via the operation switch (fig. 5/14). After approx. 5 minutes the compressed air admission is possible by connecting the compressed air compressor. The CA-dryer is designed for continuous operation and may remain switched on during periods of no load, as it adapts to the required performance automatically. Operation is indicated by the luminous operation switch (fig. 5/14). The electronic regulator shows the pressure dew point reached by the CA-dryer. At standstill periods, the CA-dryer is switched off with operation switch (fig. 5/5). For service works, the CA-dryer is switched off by pulling the power cable (Fig 5/6). At restarting proceed acc. to item 4.1. 1711.02 18 11.02 Part 4 Operation Following operation data can be recalled by operating the data selector key ( ): - Pressure dew point - Summer operation - Percentage running time of CA-dryer in relation to total running time of the system - Next condensate drain in 3 minutes 1. Press data selector key ( ) for 5 seconds to change from display- into change mode. 2. If necessary press data selector key ( ) several times until requested change mode appears. 3. Adjusting by condensate drain key ( ) 4. Press data selector key ( ) for 5 seconds to save changes and returning into display mode. 4.5 electronic regulator - operation Fig. 12: Pressure dew point Fig. 13: Percentage running time of CA-dryer Fig. 14: Condensate drain 4.6 Changing the factory setting Fig. 15: Changing factory setting Part 4 Operation Part 4 Operation 4.6.1 Change modes 4.6.1.1 P01 Activation pressure dew point-summer set value (factory setting: pressure dew point 7 °C). 4.6.1.2 P02 Acknowledgement of failures (see 5.1) 4.6.1.3 P03 Acknowledgement maintenance interval (see 5.1) 4.6.1.4 P04 Change of pressure dew point-normal set value by service. 4.6.1.5 P05 Change of pressure dew point-summer set value by service. 4.6.1.6 P06 Change of station time of condensate draining time (optimization of condensate draining) At normal operation conditions the condensate volume per condensate draining time corresponds to the values mentioned below. Type of CA-dryer 405 AP, 406AP: 407 AP: Condensate volume 40cm. - 60cm. 12cm. - 18cm. Attention! ! ! -at greater amount of condensate per condensate draining time the factor P06 must be lowered. -at smaller amount of condensate per condensate draining time the factor P06 must be raised. P06 Minimum: Factor 1 P06 factory setting: Factor 16 P06 Maximum: Factor 33 4.6.1.7 P07 Setting possibility of the pressure dew point failure limit value (factory setting 18 °C). 4.6.1.8 P08 Change °C / °F. 4.6.1.9 P09 Activation solenoid valve condensate draining. 4.6.1.10 P10 Activation automatic operation. 1911.02 20 11.02 5.1 electronic regulator maintenance display Fig. 16: Maintenance display 5.1.1 Acknowledgement maintenance interval Fig. 17: Acknowledgement maintenance interval Part 5 Maintenance Flashing maintenance symbol: - maintenance interval exceeded 1. For acknowledgement press data selector key ( ) within 5 minutes after restart the CADryer for 5 seconds. 2. Press data selector key ( ) several times until change mode P03 appears. 3. Acknowledging the maintenance interval key with condensate drain key ( ) - the maintenance symbol disappears ( ). 4. For returning into display mode press data selector key ( ) for 5 seconds Attention! Prior to any maintenance works all safety regulations for electrical systems and units must be observ...

Otros modelos de este manual:
Equipos de Bombeo - Cool 201 (580.17 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría