Iniciar sesión:
Votos - 3, Puntuación media: 3.7 ( )

Manual de usuario Goodman Mfg, modelo GSH140301A

Fabricar: Goodman Mfg
Tamaño del archivo: 829.43 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


+fan) PERFORMANCE DATA MODEL: GHS140181A* / CA*F3131B6A*+TXV / MBR800**-1 Condition: 80°F IDB 67°F IWB @ 600 CFM Outdoor Temp. ° F. Total Btuh Sensible Btuh Latent Btuh Total Watts 75° 18,900 13,282 5,618 1,367 80° 18,675 13,290 5,385 1,410 85° 18,450 13,295 5,155 1,452 90° 18,225 13,344 4,881 1,489 95 18,000 13,389 4,611 1,526 100° 17,550 13,301 4,249 1,558 105° 17,100 13,201 3,899 1,589 110° 16,470 12,768 3,702 1,616 115° 15,840 12,331 3,509 1,644 95° 16,680 13,255 3,425 1,467TVA Conditions @ 95 OD DB, 75° ID DB, 63° ID WB MODEL: GSH140241A* / CA*F3636B6A*+TXV / MBR800**1 Condition: 80°F IDB 67°F IWB @ 850 CFM Outdoor Temp. ° F. Total Btuh Sensible Btuh Latent Btuh Total Watts 75° 25,200 18,036 7,164 1,841 80° 24,900 18,048 6,852 1,896 85° 24,600 18,054 6,546 1,950 90° 24,300 18,121 6,179 1,999 95 24,000 18,181 5,819 2,047 100° 23,400 18,063 5,337 2,088 105° 22,800 17,927 4,873 2,129 110° 21,960 17,339 4,621 2,165 115° 21,120 16,745 4,375 2,200 95° 22,239 18,000 4,240 1,970 TVA Conditions @ 95 OD DB, 75° ID DB, 63° ID WB MODEL: GSH140301A* / CA*F3636B6A*+TXV / MBR1200**-1 Condition: 80°F IDB 67°F IWB @ 1,080 CFM Outdoor Temp. ° F. Total Btuh Sensible Btuh Latent Btuh Total Watts 75° 29,400 22,154 7,246 2,078 80° 29,050 22,169 6,881 2,139 85° 28,700 22,176 6,524 2,199 90° 28,350 22,259 6,091 2,253 95 28,000 22,333 5,667 2,307 100° 27,300 22,187 5,113 2,352 105° 26,600 22,020 4,580 2,398 110° 25,620 21,298 4,322 2,437 115° 24,640 20,568 4,072 2,476 95° 25,946 22,109 3,836 2,221 TVA Conditions @ 95 OD DB, 75° ID DB, 63° ID WB MODEL: GSH140361A* / CA*F4860C6A*+TXV / MBR1600**-1 Condition: 80°F IDB 67°F IWB @ 1,065 CFM Outdoor Temp. ° F. Total Btuh Sensible Btuh Latent Btuh Total Watts 75° 36,330 24,361 11,969 2,634 80° 35,898 24,377 11,520 2,712 85° 35,465 24,386 11,079 2,791 90° 35,033 24,477 10,556 2,860 95 34,600 24,558 10,042 2,929 100° 33,735 24,398 9,337 2,988 105° 32,870 24,214 8,656 3,047 110° 31,659 23,420 8,239 3,097 115° 30,448 22,618 7,830 3,148 95° 32,062 24,312 7,749 2,819 TVA Conditions @ 95 OD DB, 75° ID DB, 63° ID WB Model: GSH140421A* / CA*F4860D6A*+TXV / MBR2000**-1 Condition: 80°F IDB 67°F IWB @ 1,400 CFM Outdoor Temp. ° F. Total Btuh Sensible Btuh Latent Btuh Total Watts 75° 41,580 30,699 10,881 2,924 80° 41,085 30,719 10,366 3,010 85° 40,590 30,730 9,860 3,096 90° 40,095 30,844 9,251 3,171 95° 39,600 30,946 8,654 3,247 100° 38,610 30,744 7,866 3,311 105° 37,620 30,513 7,107 3,376 110° 36,234 29,512 6,722 3,431 115° 34,848 28,502 6,346 3,487 Model: GSH140481A* / CA*F4860D6A*+TXV / MBR2000**-1 Condition: 80°F IDB 67°F IWB @ 1,550 CFM Outdoor Temp. ° F. Total Btuh Sensible Btuh Latent Btuh Total Watts 75° 48,300 33,650 14,650 3,511 80° 47,725 33,672 14,053 3,617 85° 47,150 33,684 13,466 3,722 90° 46,575 33,809 12,766 3,816 95 46,000 33,921 12,079 3,909 100° 44,850 33,700 11,150 3,988 105° 43,700 33,447 10,253 4,068 110° 42,090 32,349 9,741 4,136 115° 40,480 31,242 9,238 4,204 95° 43,181 34,020 9,161 3,761 TVA Conditions @ 95 OD DB, 75° ID DB, 63° ID WB Model: GSH140601A* / CA*F4860D6A*+TXV / MBR2000**-1 Condition: 80°F IDB 67°F IWB @ 1,850 CFM Outdoor Temp. ° F. Total Btuh Sensible Btuh Latent Btuh Total Watts 75° 58,275 41,817 16,458 3,800 80° 57,581 41,845 15,737 3,921 85° 56,888 41,859 15,028 4,043 90° 56,194 42,015 14,179 4,151 95 55,500 42,154 13,346 4,258 100° 54,113 41,879 12,233 4,349 105° 52,725 41,564 11,161 4,441 110° 50,783 40,201 10,582 4,519 115° 48,840 38,824 10,016 4,598 95° 51,429 41,733 9,696 4,087 TVA Conditions @ 95 OD DB, 75° ID DB, 63° ID WB SPLIT SYSTEM HEATING PERFORMANCE EXPANDED PERFORMANCE DATA MODEL: GSH140181A* / CA*F3131B6A*+TXV / MBR800**-1 HEATING OPERATION Outdoor Ambient Temperature 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 0 -5 -10 MBh 22.6 21.4 20.2 18.8 18.0 17.4 16.2 14.9 13.6 12.5 11.5 10.9 10.5 9.4 8.3 7.3 6.2 5.1 Delta T 34.9 33.1 31.1 29.1 27.8 26.9 25.0 23.1 20.9 19.3 17.8 16.8 16.2 14.5 12.9 11.2 9.6 7.8 KW 1.56 1.53 1.50 1.47 1.46 1.44 1.41 1.38 1.38 1.35 1.32 1.30 1.28 1.25 1.22 1.19 1.16 1.13 AMPS 7.1 6.5 6.1 5.8 5.6 5.5 5.2 4.9 4.7 4.5 4.3 4.2 4.1 3.9 3.7 3.5 3.2 2.9 COP 4.23 4.09 3.93 3.75 3.62 3.54 3.36 3.16 2.88 2.72 2.56 2.45 2.39 2.19 1.99 1.78 1.56 1.31 EER 14.5 14.0 13.4 12.8 12.4 12.1 11.5 10.8 9.8 9.3 8.8 8.4 8.2 7.5 6.8 6.1 5.3 4.5 HI PR 248 237 228 218 213 209 201 193 185 176 169 165 162 156 150 144 139 134 LO PR 82 76 71 66 62 60 55 49 44 39 35 32 31 26 23 19 17 13 Above information is for nominal CFM and 70 degree indoor dry bulb. MODEL: GSH140241A* / CA*F3636B6A*+TXV / MBR800**1 HEATING OPERATION Outdoor Ambient Temperature 65 60 55 50 47 45 40 35 30 25 20 17 15 10 5 -5 -10 MBh 30.2 28.6 26.9 25.1 24.0 23.3 21.6 19.9 18.8 17.3 15.9 15.1 14.5 13.0 11.5 10.1 8.6 7.0 Delta T 32.9 31.1 29.3 27.4 26.1 25.3 23.5 21.7 20.4 18.9 17.4 16.4 15.8 14.2 12.6 11.0 9.4 7.7 KW 2.06 2.02 1.98 1.94 1.92 1.90 1.86 1.83 1.89 1.85 1.81 1.78 1.77 1.73 1.68 1.64 1.60 1.56 AMPS 7.9 7.6 7.5 7.3 7.2 7.2 7.1 7.0 6.9 6.8 6.7 6.7 6.6 6.5 6.4 6.4 6.2 6.1 CO...

Otros modelos de este manual:
Equipos de Bombeo - GSC140601A (829.43 kb)
Equipos de Bombeo - GSC140481A (829.43 kb)
Equipos de Bombeo - RT6213004 (829.43 kb)
Equipos de Bombeo - GSC140421A (829.43 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría