Iniciar sesión:
Votos - 4, Puntuación media: 3.8 ( )

Manual de usuario Haier, modelo HR24D2VAR

Fabricar: Haier
Tamaño del archivo: 2.65 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


The Figure 2 show a schematic of a heat pump on the cooling cycle and the heating cycle. Table 1: Model:HR18-36D2VAR MODEL: HR18D2VAR HR24D2VAR HR30D2VAR Unit Supply Voltage Normal Voltage Range Minimum Circuit Amps 208/230 60Hz 1PH 197 - 253 7.6 10.9 14.0 Max Fuse or Max CKT. BKR. (HACR per NEC ) 2 HR36D2VAR 30 16.4 11.8 78 1.6 1/3 1120 3/8"[9.52] 7/8"[22.2] 148.41[4200] [616*616*771] [682*682*813] 207[94] 222[101] 24 1/4"*24 1/4"*30 3/8" 26 7/8"*26 7/8"*32" ]0592[42.401 ]0503[77.701 ]67[761 ]38[381 24 6 7 683 28 1/2" 725 Figure 1 3 D W H cooling Capacity SEER CFM 80 85 90 95 100 105 110 115 HR18D2VAR HB2400VD1M20 M 17000 13 670 19210 19197 18020 17000 17237 16490 16712 15980 HR24D2VAR HB2400VD1M20 H 22500 13 900 25425 24683 23850 22500 22162.5 21825 21488 21150 HR30D2VAR HB3600VD1M22 L 28000 13 1125 31640 30716 29680 28000 27580 27160 26740 26320 HR36D2VAR HB3600VD1M22 H 35000 13 1240 39550 38395 37100 35000 34475 33950 33425 32900 heating Capacity HSPF CFM -10 0 10 20 30 40 50 60 HR18D2VAR HB2400VD1M20 M 15000 7.8 670 4773 6418 8036 9682 11272.73 13264 15627 18000 HR24D2VAR HB2400VD1M20 H 20000 7.8 900 6364 8558 10715 12909 15030 17685 20836 24000 HR30D2VAR HB3600VD1M22 L 26000 7.8 1125 8273 11125 13930 16782 19539 22990 27087 31200 HR36D2VAR HB3600VD1M22 H 32500 7.8 1240 10341 13906 17412 20977 24424 28738 33859 39000 Table 2: System Capacity Cooling Capacity with different outdoor temperature Heating Capacity with different outdoor temperature Outdoor Indoor ARI data of indoor Outdoor Indoor Indoor fan ARI data of indoor speed Indoor fan speed Figure 2 Heat Pump Refrigerant Circuit SERVICE VALVE SERVICE PORT DISCHARGE TEMP. SENSOR INDOOR COIL DISTRIBUTOR OUTDOOR COIL COMPRESSOR SERVICE PORT ACCUMULATOR HIGH PRESSURE LOW PRESSURE DEFROSED SENSOR CHECK VALVE ORIFICE DRIER(optional) Cooling SERVICE VALVE SERVICE PORT DISCHARGE TEMP. SENSOR INDOOR COIL DISTRIBUTOR OUTDOOR COIL COMPRESSOR SERVICE PORT ACCUMULATOR HIGH PRESSURE SWITCH LOW PRESSURE DEFROSED SENSOR CHECK VALVE ORIFICE DRIER(optional) Heating REVERSING VALVE RESNEDNOCROTAROPAVEREVERSING VALVE RESNEDNOCROTAROPAVECHECK VALVE ORIFICE SERVICE VALVE SERVICE PORT SERVICE VALVE SERVICE PORT CHECK VALVE ORIFICE DISTRIBUTOR DISTRIBUTOR !Warning -The Bi-flow drier is strongly recommended to be installed by installer and replaced once two years. This will give your equipment great help in long life. 4 4.UNIT INSPECTION This product has been inspected at the factory and released to the transportation agency without known damage. Inspect exterior of carton for evidence of rough handling in shipment. Unpack carefully. If damage is found, report immediately to the transportation agency. 5.EQUIPMENT PROTECTION FROM ENVIRONMENT The metal parts of the unit may be subject to rust or corrosion in adverse environmental conditions. This oxidation could shorten the unit life. Salt spray or mist in seacoast areas, sulphur or chlorine from lawn watering systems and various chemical contaminants from industries such as paper mills and petroleum refineries are especially corrosive. If the unit is to be installed in an area where contaminants are likely to be a problem, special attention should be given to the equipment location and exposure. Avoid having lawn sprinkler heads spray directly on the unit cabinet. In coastal areas, locate the unit on the side of the building away from the waterfront. Shielding provided by fence or shrubs may give some protection. Regular maintenance will reduce the buildup of contaminants and help to protect the unit's finish. ! WARNING - Disconnect all electrical power to the unit before servicing. Disconnect power to both the indoor and outdoor units. NOTE: There may be more than one electrical disconnect switch. Failure to shut off power can cause electrical shock resulting in personal injury or death. Frequent washing of the cabinet, fan blade and coil with fresh water. Regular cleaning and waxing of the cabinet with good automobile polish. A good liquid cleaner may be used several times a year to remove matter that will not wash off with water. The best protection is frequent cleaning, maintenance and minimal exposure to contaminants. 6.INSTALLATION 6.1.GENERAL These units are designed for outdoor installations. They can be mounted on a slab or rooftop. It is important to consult your local code authorities at the time the first installation is made. Check following points before attempting any installation: Structural strength of supporting members. Clearances and provision for servicing. Power supply and wiring. Location for minimum noise, where operating sounds will not disturb owner or neighbors. Location where there is no risk of combustible gas leakage. Location where external water drainage cannot collect around the unit. Location where roof runoff water does not pour directly on the unit. Provide gutter or other shielding at roof level. Don't locate unit in an area where excessive snow drifting may occur or accumulate. 5 Provide...

Otros modelos de este manual:
Equipos de Bombeo - HR18D2VAR (2.65 mb)
Equipos de Bombeo - HR30D2VAR (2.65 mb)
Equipos de Bombeo - HR36D2VAR (2.65 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría