Manual de usuario Pentair, modelo HP 800

Fabricar: Pentair
Tamaño del archivo: 308.19 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Open both drains and allow water to exit. Use pressurized air on the water in, one spigot only, to force the rest of the water out the other spigot. If you live in an area that experiences freezing temperatures, the heat exchanger/water coil and bypass plumbing must have all water removed to prevent freeze and chemical damage to the heat pump system. This procedure should be done prior to the first freeze along with your other pool winterizing routine. When you drain the filter system and piping you should include the heat pump as well. There should be two spigot type drains, (hose bibbs), plumbed into the heater's water in and water out piping. Place these valves as close to the heater and at the lowest point possible so as much water will drain as possible. Install two shut off valves on the water in and out lines as shown here. The rest of the water should be blown out with pressurized air to insure all water is removed. A antifreeze designed for pool equipment may be used, see a local pool professional. CAUTION! Do not add isolation valves unless you intend to clear the heat exchanger of water with pressurized air! Stagnant water left in the heat exchanger can cause corrosion and will freeze causing damage! 25 OWNER TROUBLE SHOOTING GUIDE WARNING ! Risk of electrical shock or electrocution. Improper installation will create an electrical hazard which could result in death or serious injury to pool users, installers, or others due to electrical shock, and may also cause damage to property. Do NOT attempt any internal adjustments inside the heater. 1. Keep your hands and hair clear of the fan blades to avoid injury. 2. If you are not familiar with your pool filtering system and heater: a. Do not attempt to adjust or service without consulting your dealer, professional pool or air conditioning contractor. b. Read the entire Owner and Installation Manual before attempting to use, service or adjust the heater or pool filtering system. CONDITION POSSIBLE CAUSE POSSIBLE REMEDY All control lights off. Unit will not start. No power supply to heater. Tripped breaker or blown fuse. Control failure. Reset breaker. Replace fuse. Call dealer for advise. Call factory for advise. Control Ready light ON. Low water flow through heater. Dirty or worn Clean entire filtering system and or replace Water Press. OK light OFF. filters or clogged lint traps. Clogged filter pump filter element. Inspect & clean pump impel- T-Stat On light OFF. impeller. Improper plumbing valve settings. ler. Adjust plumbing valves. Repair suc- Low & High Press. lights OFF. Suction leak allowing air into the water flow. tion air leaks, grease pump lid o-ring. Re- Unit will not start. Internal water pressure switch failure. place filter. Replace water pressure switch. Control Ready light ON. Thermostat is not set higher than the pool/spa Turn the thermostat up to the "right" more. Water Press. OK light ON. water temperature. The water temperature has Use a high quality thermometer to test the T-Stat On light OFF. reached the maximum setting. The thermostat water temperature. Maximum water tempera- Low & High Press. lights OFF. is malfunctioning. (Dual thermostat), the pool ture is 104 F + or - 3 F. Call your dealer for Unit will not start. spa select switch is not in the correct mode. advise. Call the factory for advise. Control Ready light ON. Outside air temperature below operating range Do not try to operate the heater when the Water Press. OK light ON. of 45 F., unit is in "defrost" mode. Discharge outside air temperature drops below 36 F T-Stat On light ON. air flow is restricted. Discharge air is accumuand 45 F with very high humidity or high Low Press. light OFF. lating and being drawn back through the outer wind speed. Make sure heater is installed High Press. light OFF. air coil. The fan is obstructed, low air flow. with the required placement clearances for Unit will not start.Large amounts of roof run off water restricting fan blade rotation. Sprinklers spraying on the air flow and roof clearance. Do not install indoors. Make sure that your sprinklers do OR outer air coil during cooler temperatures. Outer not spray on the heater in any way what so Unit is forming ice or frost on the air coil clogged with debris. Plants too close to ever. If ice forms on the outer coil, shut the outer air coil, usually at the bottom. heater, blocking air flow. Low refrigerant pressure caused by a Freon™ leak. Possible malfunctioning of the internal low refrigerant pressure switch. heater off and allow ice to thaw. You may use water at low pressure to thaw ice build up on the outer coil, shut the heater off when doing so. Call the factory for advice. Control Ready light ON. Low or restricted water flow through heater. Clean entire filtering system and or replace Water Press. OK light ON. Dirty or worn filters or clogged lint traps. filter element. Inspect & clean pump impel- T-Stat On light ON. Clogged filter pump impeller. Improper plumbler. Adjust all plu...

Otros modelos de este manual:
Equipos de Bombeo - HP 1000 (308.19 kb)
Equipos de Bombeo - HP 230 (308.19 kb)
Equipos de Bombeo - HP 400 (308.19 kb)
Equipos de Bombeo - HP 600 (308.19 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría