Iniciar sesión:
Votos - 4, Puntuación media: 3.5 ( )

Manual de usuario DeVillbiss Air Power Company, modelo C102D-1

Fabricar: DeVillbiss Air Power Company
Tamaño del archivo: 274.53 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


The plug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances. The outlet must have the same configuration as the plug. See illustration. DO NOT USE AN ADAPTER. Inspect the plug and cord before each use. Do not use if there are signs of damage. IMPROPER GROUNDING CAN RESULT IN ELECTRICAL SHOCK. INSTALLATION AND BREAK-IN PROCEDURES Do not modify the plug that has been provided. If it does not fit the available outlet, the correct outlet should be installed by a qualified electrician. If repairing or replacing cord or plug, the grounding wire must be kept separate from the current-carrying wires. Never connect the grounding wire to a flat blade plug terminal. The grounding wire has insulation with an outer surface that is green - with or without yellow stripes. If these grounding instructions are not completely understood, or if in doubt as to whether the compressor is properly grounded, have the installation checked by a qualified electrician. 120 Volts, 15 Amps Air Hose The air hose attached to your comporessor has an integral pressure adjusting valve at the working end of the hose. Should service or replacement be required, make sure that the pressure adjusting valve is present in the air hose line. DONOT REPLACE THE HOSE WITH STANDARD HOSE THAT IS NOT EQUIPPED WITH THE PRESSURE ADJUSTING VALVE. Do not allow hose to become kinked or pinched at any time. This is important to avoid damage to your compressor and to maintain pressure adjusting valve control. OPERATING PROCEDURES 1. Before plugging in the air compressor, set the adjustable pressure valve to "10" PSI. Make sure the "ON/ OFF" switch is in the "OFF" position. 2. Connect the air tool or accessory to the air hose. Tighten securely. 3. Plug the power cord into the grounded outlet. 4. Start the compressor by setting the "ON/OFF" switch to the "ON" position. TOO MUCH AIR PRESSURE COULD CAUSE AN AIR TOOL OR VEHICLE TIRE TO RUPTURE OR EXPLODE. CAREFULLY FOLLOW STEPS 5 AND 6 EACH TIME YOU USE YOUR COMPRESSOR. 5. Check the manufacturer's maximum pressure rating for the air tool, accessory or vehicle tire being used. The air compressor outlet pressure must never exceed the maximum pressure rating. 6. Slowly increase the pressure setting of the adjustable pressure valve. You should be able to hear and feel air pressure being relieved by the adjustable pressure valve. If pressure is not being relieved, turn the air compressor off immediately. The pressure valve must be replaced. Compressed air from the outfit may contain water condensation. Do not spray unfiltered air at an item that could be damaged by moisture. Some air operated tools or devices may require filtered air. Read the instructions for the air tool or device. TROUBLESHOOTING GUIDE VOLTAGE SOURCES, MOVING PARTS OR COMPRESSED AIR SOURCES ARE EXPOSED WHEN REPAIRING THE COMPRESSOR. PERSONAL INJURY CAN OCCUR. UNPLUG THE COMPRESSOR BEFORE ATTEMPTING ANY REPAIRS. PROBLEM CAUSE SOLUTION Air Leaks Hose fitting loose. Tighten fitting. Compressor is not delivering enough air. Prolonged excessive use of air. Hole in hose. Air leaks. Decrease the amount of air usage. Your compressor is not large enough for the air requirement. Replace the hose. Tighten fittings. Motor will not run. Fuse blown, circuit breaker tripped. Extension cord is wrong length or gauge. Loose electrical connections. Faulty motor. 1. Check fuse box for blown fuse and replace as necesssary. Reset circuit breaker. Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit. 2. Check for proper fuse. You should be using a Quick Acting fuse. 3. Check for low voltage problem. 4. Check the extension cord. 5. Disconnect the other electrical appliances from circuit or operate the compressor on its own branch circuit. Check the extension cord. Check wiring connection inside terminal box Have checked at a local Service Center. High discharge pressure. Cannot be adjusted lower. Adjustable pressure valve not functioning. RISK OF BURSTING. DO NOT OPERATE THE COMPRESSOR IF THIS PROBLEM EXISTS. ADJUSTABLE PRESSURE VALVE MUST BE REPLACED. Air Compressor Diagram 7 Slide #19 over #7 as shown. Make sure that no part of #7 tube touches #21 or #14 shroud when assembled. Parts List KEY NO. PART NUMBER / 1 ----2 CAC-1196 * 3 ----* 4 ----5 CAC-4323 * 6 ----7 CAC-1289 +8 ----/ 9 ----+ 10 ---- 11 CAC-4111 12 CAC-1342 *13 ----14 DAC-163 DAC-168 15 SSS-16 *16 ----> 17 ----> 18 ---- 19 CAC-1285 20 CAC-4322-1 21 DAC-162 DAC-167 /22 ---- DESCRIPTION Screw #10-24 x 7/8 LG hex head thd. forming (4 required) Cylinder Head Tube Seal Head Gasket Valve Plate Assembly "O" Ring Outlet Tube Rod Assembly Screw 3/8-16 x 1/25 LG hex socket flat head (torque to 350 in/lb) Cylinder Sleeve Endbell Assembly Timing Belt Pump Isolator (5 required) Shroud (right) for 102D-1 Shroud (right) for C102D-1 Switch Tank Isolator (4 required) Motor Baffle (right) Motor Baffle (left) Is...

Otros modelos de este manual:
Equipos de Bombeo - 102D-1 (274.53 kb)
Equipos de Bombeo - MGP-102D-2 (274.53 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría