Iniciar sesión:
Votos - 3, Puntuación media: 4.3 ( )

Manual de usuario Heatcraft Refrigeration Products, modelo H-IM-FP

Fabricar: Heatcraft Refrigeration Products
Tamaño del archivo: 809.03 kb
Nombre del archivo: 613181be-a74b-43ae-bdff-b76913bb0658.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


25006801 l Table of Contents Nomenclature ........................................................ 2 Field Wiring.......................................................... 12 General Safety Information...................................2 Refrigeration Charging........................................13 Compressor Module Specifications....................3-4 Operational Checkout.........................................14 Dimensional Diagrams...........................................5 System Balancing.................................................14 Condensing Unit Placement..................................6 Preventive Maintenance.................................15-17 Condensing Unit Rigging ...................................... 7 Parts ..................................................................... 18 Refrigeration Piping and Line sizing................8-10 Wiring Diagram....................................................19 Leak Detection and Evacuation...........................11 Start-up Checklist...........................................20-21 MEATM Nomenclature Nomenclature General Safety Information General Safety Information 1. Installation and maintenance to be performed only by certified personnel who are familiar with this type of equipment. 2. Make sure that all field wiring conforms to the requirements of the equipment and all applicable national and local codes. 3. Avoid contact with sharp edges and coil surfaces. They are a potential injury hazard. 4. Make sure all power sources are disconnected before any service work is done on units. Inspection Responsibility should be assigned to a dependable individual at the job site to receive material. Each shipment should be carefully checked against the bill of lading. The shipping receipt should not be signed until all items listed on the bill of lading have been accounted for. Check carefully for concealed damage. Any shortage or damages should be reported to the delivering carrier. Damaged material becomes the delivering carrier’s responsibility and should not be returned to the manufacturer unless prior approval is given to do so. When uncrating, care should be taken to prevent damage. Heavy equipment should be left on its shipping base until it has been moved to the final location. © 2004, Heatcraft Refrigeration Products LLC 2 Compressor Module Specifications Compressor Module Specifications a HP Hermetic Compressor Model Compressor Electrical Rating Compressor Data RLA = MCC/1.56 Crankcase Heater Watts Refrigerant Evap. Temp. Volts Phase Hz RLA LRA MCC Type Lbs. Min. Max High Temp. 1/2 ART82C1-CAV 208-230 1 60 5.9 30.0 5.9 48 22 10 0 40 1 1/2 CR18KQ-PFV 208-230 1 50/60 8.1 41.0 12.6 40 22 10 0 40 1 1/2 CR18KQ-TF5 208-230 3 50/60 4.9 40.0 7.7 40 22 10 0 40 2 CR24KQ-PFV 208-230 1 50/60 12.2 70.5 19.0 40 22 10 0 40 2 CR24KQ-TF5 208-230 3 50/60 5.1 55.0 8.0 40 22 10 0 40 3 CR37KQ-PFV 208-230 1 50/60 16.7 100.3 26.0 40 22 25 0 40 3 CR37KQ-TF5 208-230 3 50/60 9.9 85.0 15.5 40 22 25 0 40 4 CR53KQ-PFV 208-230 1 50/60 26.0 140.0 40.5 40 22 25 0 40 4 CR53KQ-TF5 208-230 3 50/60 16.3 107.0 25.5 40 22 25 0 40 5 CRN-0500-PFV 208-230 1 60 30.8 142.0 48.0 40 22 25 0 40 5 CRN-0500-TF5 208-230 3 60 19.2 130.0 30.0 40 22 25 0 40 3/4 RS64C2-CAV 208-230 1 50/60 6.9 37.0 10.8 42 22 10 0 30 1 RS70C1-PFV 208-230 1 60 6.3 34.2 9.8 42 22 10 0 40 Medium Temp. 1 1/2 CS10K6E-PFV 208-230 1 60 9.8 56.0 15.3 40 404a 9 -25 30 1 1/2 CS10K6E-TF5 208-230 3 60 6.7 51.0 10.5 40 404a 9 -25 30 2 CS12K6E-PFV 208-230 1 60 9.8 56.0 15.3 40 404a 9 -25 30 2 CS12K6E-TF5 208-230 3 60 6.7 51.0 10.5 40 404a 9 -25 30 2 1/2 CS14K6E-PFV 208-230 1 60 11.2 61.0 17.4 40 404a 9 -25 30 2 1/2 CS14K6E-TF5 208-230 3 60 8.2 55.0 12.8 40 404a 9 -25 30 3 CS18K6E-PFV 208-230 1 60 14.4 82.0 22.4 40 404a 22 -25 30 3 CS18K6E-TF5 208-230 3 60 9.4 65.5 14.6 40 404a 22 -25 30 3 1/4 CS20K6E-PFV 208-230 1 60 16.7 96.0 26.0 40 404a 22 -25 30 3 1/4 CS20K6E-TF5 208-230 3 60 10.3 75.0 16.0 40 404a 22 -25 30 4 CS27K6E-PFV 208-230 1 50/60 21.5 121.0 33.5 40 404a 22 -25 30 4 CS27K6E-TF5 208-230 3 50/60 13.7 105.0 21.4 40 404a 22 -25 30 5 CS33K6E-PFV 208-230 1 50/60 27.6 125.0 43.0 40 404a 22 -25 30 5 CS33K6E-TF5 208-230 3 50/60 16.8 102.0 26.2 40 404a 22 -25 30 1/2 RS43C2E-CAV 208-230 1 50/60 4.8 24.1 7.5 45 404a 9 -25 30 3/4 RS55C2E-CAV 208-230 1 50/60 5.4 40.0 8.5 45 404a 9 -25 30 1 RS64C2E-CAV 208-230 1 50/60 6.9 37.0 10.8 45 404a 9 -25 30 1 RS70C1E-PFV 208-230 1 60 6.3 34.2 9.8 45 404a 9 -25 30 Low Temp. 1 CF04K6E-PFV 208-230 1 60 8.6 59.2 13.4 50 404a 9 -40 0 1 CF04K6E-TF5 208-230 3 60 5.7 52.0 8.9 50 404a 9 -40 0 1 1/2 CF06K6E-PFV 208-230 1 60 10.3 59.2 16.0 50 404a 9 -40 0 1 1/2 CF06K6E-TF5 208-230 3 60 6.3 52.0 9.8 50 404a 9 -40 0 2 1/2 CF09K6E-PFV 208-230 1 60 15.0 87.0 23.4 50 404a 9 -40 0 2 1/2 CF09K6E-TF5 208-230 3 60 9.2 72.2 14.3 50 404a 9 -40 0 3 CF12K6E-PFV 208-230 1 60 18.4 105.0 28.7 50 404a 9 -40 0 3 CF12K6E-TF5 208-230 3 60 11.0 85.0 17.2 50 404a 9 -40 0 3 Compressor Module Specifications Co...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría