Damaged protection devices or parts must be repaired or replaced by an qualified specialist. Have damaged switches replaced by a service centre. Do not operate electric tool if the switch can not be turned ON or OFF. Keep handles free of oil and grease. 9 ENGLISH 3.3 Safety devices Safety valve The spring safety valve (12) is incorporated into the pressure switch unit. The safety valve opens if the max. permissible pressure is exceeded. 4.1 Mains connection BDanger! High voltage Operate device in dry environment only. Operate device only on a power source complying with the following requirements: . outlets properly installed, earthed and tested; . fuse protection in accordance with the Technical Specifications. Position power cable so it does not interfere with the work and is not damaged. Always check to see that the device is switched OFF before plugging in. Protect power cable from heat, aggressive liquids and sharp edges. Use only extension cables with sufficient lead cross section (see "Technical Specifications"). Do not stop the compressor by unplugging, but switch OFF using the switch. Unplug after use. 4.2 Generating compressed air 1. Start device (13) and wait until the max. tank pressure is reached (compressor shuts off). The tank pressure is indicated by the tank pressure gauge (14). 2. Set pressure regulator (15) to required working pressure. The current working pressure is indicated by the regulated pressure gauge (16). A Caution! The regulated pressure may not be set higher than the max. working pressure of the connected air tools! 3. Connect air hose to compressed air outlet (17). 4. Connect air tool. You are now ready to work with the air tool. 5. Switch the device OFF, if you do not continue working immediately afterwards. Unplug after switching OFF. ADanger! Prior to all servicing: . Switch Off. . Unplug. . Wait until the device has come to a complete stop. . Ensure the device and all air tools and accessories connected to it are relieved from pressure. . Let the device and all air tools and accessories used cool off. After all servicing: . Check to see that all safety devices are operational. . Make sure that no tools or other parts remain on or in the device. Repair and maintenance work other than described in this section must only be carried out by qualified specialists. 5.1 Periodic maintenance Prior to each use • Check air hoses for damage, replace if necessary. • Check all screwed connections for tightness, tighten if necessary. • Check power supply cable for damage, if necessary have replaced by a qualified electrician. Every 50 operating hours • Check air intake filter (18), clean if necessary. • Drain condensate (19). Every 250 operating hours • Replace air filter element. 5.2 Device storage 1. Switch unit OFF and unplug. 2. Release pressure from tank and all connected air tools. 3. Store device in such way that it cannot be started by unauthorized persons. A Caution! Do not store device unprotected outdoors or in damp environment. Do not lay device on its side for transportation or storing. ADanger! Prior to all servicing: . Switch Off. . Unplug. . Wait until the device has come to a complete stop. . Ensure the device and all air tools and accessories connected to it are relieved from pressure. . Let the device and all air tools and accessories used cool off. 4. Operation 12 5. Care and Maintenance 15 16 13 14 17 6. Trouble Shooting 18 19 ENGLISH After all servicing: . Check to see that all safety devices are operational. . Make sure that no tools or other parts remain on or in the device. Compressor does not run: • No mains voltage. . Check cables, plug, outlet and mains fuse. • Mains voltage too low. . Use only extension cables with sufficient lead cross section (see "Technical Specifications"). Avoid using extension cable with cold device. • Compressor was stopped by unplugging. . Switch compressor OFF at the On/Off switch, then ON again. • Motor has overheated, caused by insufficient cooling (cooling fins covered). 9. Technical Specifications . Remove cause for overheating and allow to cool down for approx. 10 minutes, then start again. Compressor runs but does not build up sufficient pressure. • Condensate drain of pressure vessel leaky. . Check gasket of drain screw(s); replace if necessary. . Tighten drain screw(s) fingertight. • Check valve leaky. . Have check valve serviced by qualified service centre. Air tool is not supplied with sufficient pressure. • Pressure regulator not opened wide enough. . Open pressure regulator more. • Hose connection between compressor and air tool leaky. . Check air hoses, replace defective parts if necessary. 7. Repairs A A Danger! Repairs to power tools must be carried out by qualified electricians only! Electric tools in need of repair can be send to the service centre in your country. See spare parts list for address. Please attach a description of the fault to the power tool. 8. Environmental Protection The device's packaging can be 1...