Iniciar sesión:
Votos - 2, Puntuación media: 4 ( )

Manual de usuario Sanyo, modelo 18KHS22

Fabricar: Sanyo
Tamaño del archivo: 205.93 kb
Nombre del archivo: SUB18KHS22-19770717.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


(A) 30 Fuse size, Max. (A) 30 COMPRESSOR Rotary-Hermetic No. used 1 R.L. Amps - L.R. Amps (A) 7.1 - 52.0 Crankcase Heater (W) 30 OUTDOOR FAN - TYPE Propeller Dia. (in.) - No. used 15 3/4 - 1 Type Drive - No. speeds Direct - 2 No. Poles - RPM (High) 6 - 1,020 No. Motors - HP 1 - 1/12 CFM (High) 1,190 F.L. Amps. (A) 0.5 OUTDOOR COIL - TYPE Aluminum Fin & Copper Pipe Fin Type - Pipe Type Slit Plate - Inner Riffled Rows - F.P.I. 2 - 15.9 Face Area (sq.ft.) 5.34 Tube Size (in.) 3/8 INDOOR FAN - TYPE Cross - Flow Dia. & Length (in.) - No. used 4 & 30-1 No. speeds 3 & Auto No. Poles -RPM (High) 4-1,600 No. Motors - HP 1 - 1/75 CFM (HI/MED/LOW) 440/380/320 F.L. Amps (A) 0.4 INDOOR COIL - TYPE Aluminum Fin & Copper Pipe Fin Type - Pipe type Slit Plate - Inner Riffled Rows - F.P.I. 2 - 14.1 Face Area (sq. ft.) 2.08 Tube Size (in.) 3/8 Drain Connection Size (in.) 1 - 1/4 ÎA^lYÜ AIRCONDITIONING PRODUCTS SS18KHS22-1 REFRIGERANT Lbs. - R22 (O.D. Unit) Control Connection Line Length, Max (ft.) Lift difference, Max (ft.) Line Size - in. O.D. Discharge Line Size - in. O.D. Suction R22 4.25 Capillary Tube Flare 65 23 1/4 5/8 WEIGHT INDOOR OUTDOOR Net (lbs.) 29.8 134.5 Shipping (lbs.) 37.5 143.3 Shipping Volume (cu.ft.) 4.8 10.3 PERFORMANCE DATA @ ARI STANDARD CONDITIONS (230/208V) COOLING Total Capacity (BTU/H) Sensible Capacity (bTU/h) Latent Capacity (BTU/h) SEER Dehumidification (Pints/H) Amps (A) Power Inputs (W) HEATING Total Capacity (BTU/H) HSPF Amps (A) Power Inputs (W) Back-up Strip Heater (KW) Outdoor Sound Rating (bels) FEATURE 16,500/16,000 10,390/10,060 6,110/5,940 10.0/10.0 5.3/5.2 8.0/8.6 1,810/1,760 18,000/17,600 6.8/6.8 8.0/8.6 1,810/1,760 1.80/1.47 7.8 Controls Remote Controller Temperature Control Timer Night Setback Air Louve (Horizontal) (Vertical) Power Failure Automatic Restart Self Diagnosis Heating/Cooling Automatic Changeover OPTION Microprocessor LCD Wireless type IC Thermostat ON/OFF, 24 hours Built-In Manual Automatic Built-In Built-In Built-In Refrigerant Line Set AP2507BH (20 ft) AP2510BH (30 ft) AP2515BH (50 ft) Low Ambient Control N/A Fresh Air Intake N/A Central Remote ON-OFF Control Available Airduct Extension N/A Indoor Frame Extension PLB 182 Condensate Drain Pump Available Non-Removable Remo-con Bracket Available OPERATING RANGE DIMENSIONS (in.) H x W x D Cooling Indoor Unit -Uncrated 14- 3/16 x 39 x 7-13/16 -Crated 18 x 42-17/32 x 10-23/32 Outdoor unit -Uncrated 24-13/16 x 32-11/16 x 12-13/32 -Crated 28- 3/32 x 39- 5/32 x 16- 9/32 Heating Maximum Minimum Maximum Minimum CERTIFICATION Indoor Air Intake Temp. 95 F DB/71 F WB 67 F DB/57 F WB 80 F DB/67 F WB - F DB/ - F WB Outdoor Air Intake Temp. 115 F DB 67 F DB 75 F DB / 65 F WB 17 F DB/ 15 F WB 18KHS22 DIMENSIONAL DATA Indoor Unit: KHS1822 Rear panel (Center point of gravity) Wireless remote control unit 1^—I -I k-2-13/64 19/32 Outdoor Unit: CH1822 21-3/16 5-3/4 Air intake Check port 1/4 narrow tubing service valve 5/8 wide tubing service valve la._fi__ o -0 WARRANTY SANYO products are warranted against defects in materials and workmanship for the period below; LABOR PARTS Compressor 30 Days 5 Years Other Components N/A 1 Year Full specific warranty rights, conditions, exclusions and obligations are specified in the warranty packed with each products. Because of a policy of continuous product improvements, SANYO reserves the right to change specifications and design without notice. SANYO FISHER COMPANY A Division of SANYO North America Corporation 21605 Plummer St. Chatsworth, CA 91311 Phone : (818) 998- 7322 Fax : (818)701-4160 Website: http://www.sanyohvac.com...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría