|
Resumen del manual
Will cause serious injury or death ingersoll-Rand air compressors are not designed, intended or approved for breathing air Compressed air should not be used for breathing air applications unless treated in accordance with all applicable codes and regulaUons,, WARNING HAZARDOUS VOLTAGE Can cause serious injury or death. Disconnect power and bteed pressure from tank before servicing Lockout/Tagout machine. Compressor must be connected to properly grounded circuit See grounding instructions in manuat, Do not operate compressor tn wet conditions,, Store indoors MOVING PARTS, Can cause serious injury Do not operate with guards removed. Machine may start automatically Disconnect power before servicing_ Lockout/Tagout machine,, HOT SURFACES, Can cause serious injury, r DO not touch Allow to cool before servicing Do not touch hot compressor or tubing HIGH PRESSURE AIR. Bypassing_ modifying or removing safety/relief valves can cause serious injury or death, Do not bypass, modify or remove safety/relief valves Do not direct air stream at body. Rusted tanks can cause explosion and severe injury or death Drain tank daily or after each use. Drain valve located at bottom of tank. z_ CAUTION RISK OF BURSTING. Use only suitable air handling parts acceptable for pressure of not less than the maximum allowable working pressure of the machine. Owner's Manual Installation, Operation and Maintenance Instructions for Models SS3 and SS5 Stationary Air Compressors THESE INSTRUCTIONS. RETAIN FOR REFERENCE. Your air compressor unitis suitable for operating air too_s, caulking guns, grease guns, sandblasters, etc Depending on your application, the following accessories may be required: @ An air pressure regulator to adjust the alr pressure enlering the toot or accessory • An air line fitter for removal of moisiure and oil vapor in compressed air • An in-line lubricator to prolong lhe life of air tools. ql, Separate air transformers which combine the !'unctions of air regulation andlor moisture and dirt removal Cenlact your nearest authorized dealer or cal! 1-800-AIR-SERV for more information on air toots and accesser}as for your application Ensure adequate lifting equipment is available for unloading and moving your unit to the inslaIlatton site NOTE: Lifting equipment must be property rated for the weight of the unit. Lift the unit by the shipping skid only,,Use straps to prevent tipping Lk CAUTION Do not work on or walk under the compressor while it is suspended, -........... Be[ore signing the deliveryreceipl,inspecl for damage and missing parts If damage or missing parts are apparenL make the appropriate notation on the delivery receipt, then sign the receipt. Immediately contact the carrier for an inspection. All material must be held in the receiving location for the carrier's inspection Deiivery receipts that have been signed without a notation of damage or missing parts are considered to be delivered "clear" Subsequent claims are then considered to be concealed damage claims SeUle damage claims directly with the transportation company Lf you discover damage after receiving the unit (concealed damage), the carrier must be notified within 15 days of receipt and an inspection must be requested by telephone with confirmation in writing On concealed damage claims, the burden of establishing that the unit was damaged in transit reverts back to the claimant Read lhe unit specification labei to verify it is the mode! ordered. and read the meier nameplate to verify il is compatibJe with your e_ectrical conditions Make sure electrical enclosures and componenls are appropriate for your applicafion © IngersolL-Rand Company Form SCD-B77A Printed in U S A March 2002 SELECTINGLOCATION A GENERAL° Select a clean, dry, welt-lighted indoor area with plenty of space far proper cooling air flow and accessibility. Locate the unit at least 12 inches (30 cm) from wails, and make sure the main power supply is clearly identified and accessible TEMPERATURE.. Ideal operating temperatures are between 32"F and 100°F (0°C and 37.B_C) If temperatures consistently drop below 32°F (0"C), locale the unit inside a heated building !f th_s is not possible, you must protect safety!relief valves and drain valves from freezing CAUTION Never operate in temperatures below 20°F (_6.6°C) or above 125°F (5t.0°C).. HUMID AREAS. In frequently humid areas, moisture may form in the bare pump and produce sfudge in the lubricant, causing running parts to wear out prematurely Excessive moisture is especially likely to occur if the unit is located in an unheated area that is subject to large temperature changes Two signs of excessive humidity are external condensation on the bare pump when it cools down and a "_mllky_ appearance in petroleum compressor lubricant You may be able to prevent moisture from forming in the bare pump by increasing ventilation, operating for longer intervals or installing a crankcase heater kit NOISE CONSIDERATIONS Consull local officials [or informatio...
Otros modelos de este manual:Equipos de Bombeo - SS5 (1015.26 kb)
Equipos de Bombeo - SS5L5 (1015.26 kb)
Equipos de Bombeo - SS5N5 (1015.26 kb)