Iniciar sesión:
Votos - 3, Puntuación media: 4 ( )

Manual de usuario RIDGID, modelo OF45150

Fabricar: RIDGID
Tamaño del archivo: 1.02 mb
Nombre del archivo: d1e5e25c-6dd1-439f-9111-b76a4360bc72.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


IN610300AV Printed in U.S.A. Table of Contents Section Page Table of Contents . . . . . . . . . . . . . . . .2 Safety Instructions . . . . . . . . . . . . . . .3 Safety Signal Words . . . . . . . . . . . . .3 Before Using the Air Compressor . . . . . . . . . . . . . . . . . . . .3 Spraying Precautions . . . . . . . . . . . .5 Breathable Air Warning . . . . . . . . . . .5 Warning Labels . . . . . . . . . . . . . . . . .6 Motor Specifications and Electrical Requirements . . . . . . . . . .7 Power Supply and Motor Specifications . . . . . . . . . . . . . . . . . .7 General Electrical Connections . . . . .7 110-120 Volt, 60 Hz Tool Information . . . . . . . . . . . . . . . . . . . .8 Extension Cords . . . . . . . . . . . . . . . .9 Thermal Overload Protector . . . . . . .9 Glossary of Terms . . . . . . . . . . . . . . .9 Unpacking and Checking Content . . . . . . . . . . . . . . . . . . . . . . .10 Installation . . . . . . . . . . . . . . . . . . . .10 Section Page Getting to Know Your Air Compressor . . . . . . . . . . . . . . . . . . .11 Regulated Outlet Gauge . . . . . . . . .11 Tank Pressure Gauge . . . . . . . . . . .11 Regulator Knob . . . . . . . . . . . . . . . .12 Air Filter . . . . . . . . . . . . . . . . . . . . . .12 ASME Safety Valve . . . . . . . . . . . . .12 Operating Your Air Compressor . . .13 For Trouble-Free Operation . . . . . .13 Moisture in Compressed Air . . . . . .13 Maintenance . . . . . . . . . . . . . . . . . . .13 Tank . . . . . . . . . . . . . . . . . . . . . . . . .14 Filter Removal, Inspection, and Replacement . . . . . . . . . . . . . . . . . .15 Lubrication . . . . . . . . . . . . . . . . . . . .15 Storage . . . . . . . . . . . . . . . . . . . . . .15 Maintenance Schedule . . . . . . . . . .15 Troubleshooting . . . . . . . . . . . . . . . .16 Repair Parts . . . . . . . . . . . . . . . . . . .18 Notes . . . . . . . . . . . . . . . . . . . . . . . . .22 Warranty . . . . . . . . . . . . . . . . . . . . . .24 Safety Instructions This manual contains information that is Warning indicates very important to know and understand. ! WARNING a potentially haz- This information is provided for SAFETY ardous situation which, if not avoided, and to PREVENT EQUIPMENT PROB COULD result in death or serious injury. LEMS. To help recognize this informa- Caution indicates a tion, observe the following symbols. ! CAUTION potentially haz- Safety Signal Words ardous situation which, if not avoided, MAY result in minor or moderate injury. !DANGER Danger indicates an imminently haz- Notice indicates NOTICE important informa- WILL result in death or serious injury. tion, that if not followed, may cause damage to equipment. ardous situation which, if not avoided, Before Using the Air Compressor Air compressors are utilized in a variety objects, chemical spills, oil, solvents, of air system applications. Because air and wet floors. compressors and other components 4. Never point a spray gun at oneself or (material pump, spray gun, filters, lubri any other person. Accidental dis- cations, hoses, etc.) used make up a charge may result in serious injury. high pressure pumping system, the fol 5. Check hoses for weak or worn condilowing safety precautions should be tion, before each use, making certain observed at all times. Only persons well all connections are secure; do not acquainted with these rules of safe oper use if deficiency is found. Notify an ation should be allowed to use the air authorized service facility for exami compressor. nation or repair. All electrical work should be done by a qualified (licensed or certified) electrician. On a prop- erly wired circuit, the black wires supply a voltage potential even when the unit is off. !WARNING 1. Read instruction manuals for each component carefully, before attempting to assemble, disassemble or operate your particular system. 2. Do not exceed pressure rating of any component in system. 3. Protect material lines and air lines from damage or puncture. Keep hose and power cable away from sharp 3 6. Release all pressures within system slowly; dust and debris may be harmful. Disconnect power and depressurize system before servicing air compressor! (Turn pressure regulator knob fully clockwise after shutting off compressor.) !WARNING 7.Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupational Safety and Health Act (OSHA). 2 Safety Instructions (continued) 8. Wiring and fuses should follow electrical codes, current capacity, and be properly grounded. 9. Electric motors must be securely and adequately grounded. See grounding instructions and extension cord information, in this manual. 10. Always disconnect power source before working on or near a motor, or its connected load. If power disconnect point is out-of-sight, lock it in the open position and tag to prevent unexpected application of power. 11. Guard all moving parts; keep visitors away. Never allow children in work area. 12. Use only a properly g...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría