Iniciar sesión:
Votos - 2, Puntuación media: 4.5 ( )

Manual de usuario York, modelo 036-048

Fabricar: York
Tamaño del archivo: 231.72 kb
Nombre del archivo: 35496869-7da1-47c1-ab71-48043acb452c.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


For tubing lengths other than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value. CAB All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. DIMENSIONS Unit Model Dimensions (Inches) Refrigerant Connection Service Valve Size A1 B C Liquid Vapor 036 25 35 23 3/4” 048 33 37 27 3/8” 7/8” 060 26 43 32 7/8” 1. Including fan guard. Unitary Products Group 279104-YTG-B-0307 Additional R-22 Charge / Orifice Size for Various Matched Systems Outdoor Unit E1RA036S(25,46) E1RA048S(25,46) E1RA060S(25,46) Unit Orifice (s) 1 71, 81 81, 84, 87 99 Factory R-22 Charge, lbs-oz 5 - 12 8 - 3 11 - 3 Indoor Coil FC/MC/PC35(B,C)3X FC/MC/PC/UC36(A,B,C)3X FC/MC/PC/UC42(B,C)3X FC/MC/PC/UC48C3X FC/MC/PC/UC48D3X FC/MC/PC/UC60C3X FC/MC/PC/UC60D3X AHP36C3X AHP42C3X AHP/SHP48D3X AHP60D3X G1NA036S17L G1NA048S21D G1NA048S24P G1UA048S21/24 G1UA060S24 G1FA048S21/24 G1FA060S24 G2FD042S21 G2FD048S21/24 G2FD060S24 81 + 8 71 + 7 81 + 8 – – – – 81 + 13 81 + 13 – – 71 + 7 71 + 7 – 81 + 13 – 81 + 13 – 81 + 8 – – System Orifice = Additional Charge, Oz – – – 87 + 6 87 + 6 84 + 4 84 + 4 84 + 3 84 + 3 84 + 4 84 + 4 – 81 + 8 81 + 8 84 + 3 84 + 4 84 + 3 84 + 4 – 87 + 6 84 + 4 – – – – – 99 + 0 99 + 0 – – 99 + 0 99 + 0 – – – – 99 + 0 – 99 + 0 – – 99 + 0 FOOTNOTES: 1. These orifices are packed in the instruction/warranty packet of each outdoor unit. PROCEDURES: 1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of interconnecting line tubing. 2. Verify the orifice size and additional charge required for specific evaportor coil in the system using the above table. 3. Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above. 4. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaportor + adder for line set. 5. If the orifice in the evaportor was changed, verify the evaportor nameplate has been marked with the correct orifice size. Unitary Products Group 279104-YTG-B-0307 COOLING CAPACITY - With Air Handler Coils UNIT MODEL AIR HANDLER COIL1 MODEL COOLING MODEL ELECTRIC 2 HEAT KW W RATED CFM NET MBH SEER W/O TXV SEER WITH TXV3 EER TOTAL SENS. 3 PH 10 SEER HP WITH MA / MC / N-AH / G2FD E1RA036S(25,46) MA12BN2,4 10 17 FC/MC35B3X 1250 34.4 25.3 10 – 8.95 MA12BN2,4 10 17 FC/MC36B3X 1250 34.4 25.3 10 – 8.95 MA12BN2,4 10 17 FC/MC42B3X 1250 34.4 25.3 10 – 8.95 N1AHC1646 10, 15 21 G2FD042(S,H)21 1250 34.2 25.3 10 – 8.95 E2RA048S(25,46 MA16CN4 10, 15 21 FC/MC48C3X 1600 45.5 33.7 10 – 9.45 MA20DN2 10, 15, 25 24 FC/MC48D3X 1725 45.5 33.7 10 – 9.45 MA20DN4 10, 15, 29 24 FC/MC48D3X 1725 45.5 33.7 10 – 9.45 N1AHC1646 10, 15 21 G2FD048(S,H)21 1600 45.5 33.7 10 – 9.45 N1AHD2046 10, 15, 29 24 G2FD048(S,H)24 1600 45.5 33.7 10 – 9.45 E1RA060S(25,46) MA20DN4 10, 15, 29 24 FC/MC60D3X 2000 57.0 41.0 10 – 9.80 N1AHD2046 10, 15, 29 24 G2FD048(S,H)24 1700 57.0 41.0 10 – 9.80 3 PH 10 SEER HP WITH AHP / SHP / F2RP / RC / FP / FC4,5 E1RA036S25 F2RP/FP036 5, 8, 10, 15, 19 21 – 1250 34.0 24.9 10 – 9.00 F2RD/FP042 5, 8, 10, 15 21 – 1250 34.0 25.6 10 – 9.00 AHP36C3X 10, 15 21 – 1250 34.0 25.6 10 – 9.00 AHP42C3X 10, 15, 18 21 – 1250 34.0 25.6 10 – 9.00 E2RA048S25 F2FP048 5, 8, 10, 15, 20, 25 24 – 1600 45.0 33.5 10 – 9.40 F2FP060 5, 8, 10, 15, 20, 25 24 – 1600 46.5 34.4 10 – 9.60 AHP/SHP48D3X 10, 15, 18 24 – 1600 46.5 34.4 10 – 9.60 E1RA060S25 F2FP060 5, 8, 10, 15, 20, 25 24 – 1700 56.0 40.0 10 – 9.40 AHP/SHP60D3X 10, 15 24 – 1700 56.0 40.0 10 – 9.40 Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210/240. Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow. KW includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blower motor. EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period. 1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number. 2. Single phase units require single phase 2HK heaters. 3. TXV = Use 1TV700 Series Kit. 4. To meet R=4.2 insulation requirements, substitute F2FP for F2RP, and F2FC for F2RC. models. All ratings remain the same. 5. FG8, FG9, and FL8 furnaces and F2RP / F2RC air handlers have B.O.D. standard. - = Not applicable Unitary Products Group 279104-YTG-B-0307 COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils UNIT MODEL FURNACE** COIL MODEL COOLING CFM RANGE (MIN.-MAX.) W RATED CFM NET MBH SEER W/O TXV SEE...

Otros modelos de este manual:
Equipos de Bombeo - 060 (231.72 kb)
Equipos de Bombeo - 090 (231.72 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría