Manual de usuario York, modelo SUNLINE 2000 B1CH180

Fabricar: York
Tamaño del archivo: 769.74 kb
Nombre del archivo: 6e0890d9-e570-4f21-970c-9c1daccd1ea1.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


SINGLE PACKAGE HEAT PUMPS WITH OR WITHOUT SUPPLEMENTAL ELECTRIC HEAT INSTALLATION INSTRUCTION Supersedes: 511.06-N3Y (1294) 511.06-N3Y (500) 035-12546-000 MODELS B1CH180 & 240 (8.5 - 8.8 EER) 208/230/575 VOLT MODELS ONLY 208/230/460 VOLT MODELS ONLY SAFETY CONSIDERATIONS Due to system pressure, moving parts and electrical components, installation and servicing of air conditioning equipment can be hazardous. Only qualified, trained, service personnel should install, repair, maintain or service this equipment. Observe all precautions in the literature, on labels and tags accompanying the equipment whenever working on air conditioning equipment. Be sure to follow all other safety precautions that apply. Wear safety glasses and work gloves, and follow all safety codes. Use a quenching cloth and have a fire extinguisher available for all brazing operations. GENERAL YORK Model BCH units are single package heat pumps designed for outdoor installation on a rooftop or a slab. These units can be equipped with factory installed electric heaters for cooling/heating applications. The units are completely assembled on rigid, permanently attached base rails. All piping, refrigerant charge, and electrical wiring is factory installed and tested. The units require electric power, duct connections and installation of fixed outdoor air intake damper (units without economizer or motorized damper option only) at the point of installation. The supplemental electric heaters have nickel-chrome elements and utilize single point power connection. INSPECTION As soon as a unit is received, it should be inspected for possible damage during transit. If damage is evident, the extent of the damage should be noted on the carrier’s freight bill. A separate request for inspection by the carrier’s agent should be made in writing. Refer to Form 50.15-NM for additional information. REFERENCE Additional information on the design, installation, operation and service of this equipment is available in the following reference forms: • 55.70-N1 - General Installation • 55.70-N2 - Pre-start & Post-start Check List • 44-320-10 - Barometric Relief Damper Accessory Renewal Parts: • Refer to the Renewal Parts Manual for complete listing of replacement parts on this equipment. All forms referenced in this instruction may be ordered from: Standard Register Norman, OK 73069 Toll Free: Tel. 877-318-9675/Fax. 877-379-7920 APPROVALS Design certified by ETL & CGA as follows: 1. For use as a heat pump only unit or a heat pump with or without supplemental electric heat. 2. For outdoor installation only. 3. For installation on combustible material. CAUTION THIS PRODUCT MUST BE INSTALLED IN STRICT COMPLIANCE WITH THE ENCLOSED INSTALLATION INSTRUCTIONS AND ANY APPLICABLE LOCAL, STATE, AND NATIONAL CODES INCLUDING, BUT NOT LIMITED TO, BUILDING, ELECTRICAL, AND MECHANICAL CODES. WARNING INCORRECT INSTALLATION MAY CREATE A CONDITION WHERE THE OPERATION OF THE PRODUCT COULD CAUSE PERSONAL INJURY OR PROPERTY DAMAGE Installer should pay particular attention to the words: NOTE, CAUTION and WARNING. Notes are intended to clarify or make the installation easier. Cautions are given to prevent equipment damage. Warnings are given to alert installer that personal injury and/or equipment damage may result if installation procedure is not handled properly. 511.06-N3Y TABLE OF CONTENTS General ................................................................................ 1 Inspection............................................................................. 1 Reference............................................................................. 1 Approvals ............................................................................. 1 Nomenclature....................................................................... 2 INSTALLATION Limitations............................................................................ 3 Location ............................................................................... 3 Rigging and Handling .......................................................... 3 Clearances........................................................................... 3 Ductwork .............................................................................. 3 Fixed Outdoor Air Intake Damper ........................................ 4 Condensate Drain................................................................ 4 Compressors........................................................................ 4 Filters ................................................................................... 4 Service Access .................................................................... 4 Thermostat........................................................................... 4 Power and Control Wiring .................................................... 4 Optional Electric Heaters..................................................... 5 Optional Economizer/Mot. Damper Rain Hood ................

Otros modelos de este manual:
Equipos de Bombeo - SUNLINE 2000 B1CH240 (769.74 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría