Iniciar sesión:
Votos - 1, Puntuación media: 5 ( )

Manual de usuario Fedders, modelo CH18ABD1VF

Fabricar: Fedders
Tamaño del archivo: 131.37 kb
Nombre del archivo: 67d74c91-2fb4-4ef3-9e68-ce7bf9e3455c.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Additional rating information can be found at Residential & Light Commercial HVAC Model Number Size (tons) Refrigerant Nominal BTUH Min. Circuit Ampacity 2Max. Fuse or Breaker Operating Dimensions H x W x D (inches) Min. Mounting Pad Size (inches) Ship / Operating Weight (lbs) CH18ABD1VF 1 1.2 R-22 18,000 13.5 20 32 1.2 X 21 1.2 X 21 1.2 24 x 24 132 / 127 CH24ACD1VF 2 R-22 24,000 16.0 25 32 1.2 X 29 1.2 X 29 1.2 32 x 32 195 / 186 CH30ACD1VF 2 1.2 R-22 30,000 18.8 30 32 1.2 X 29 1.2 X 29 1.2 32 x 32 195 / 186 CH36ACD1VF 3 R-22 36,000 20.5 35 32 1.2 X 29 1.2 X 29 1.2 32 x 32 197 / 188 CH42ACD1VF 3 1.2 R-22 42,000 24.8 40 32 1.2 X 29 1.2 X 29 1.2 32 x 32 208 / 201 CH48ACD1VF 4 R-22 48,000 27.3 45 32 1.2 X 29 1.2 X 29 1.2 32 x 32 212 / 203 CH60ACZ1VF 5 R-410A 60,000 38.4 60 39 X 29 1.2 X 29 1.2 32 x 32 258 / 249 Split System Heat Pump 11.2 thru 5 Tons 208/230 Volt, 1-Phase, 60 Hz Performance: Efficiency rating of 13 SEER Cooling capacities from 11.2 to 5 tons Refrigerant Circuit: Factory installed biflow liquid line filter drier Long life copper tubes, aluminum fins State-of-the-art compressors Large, wrap-around coil surface Quality Built: Galvanized steel exterior cabinet with 1,000-hour salt spray, powder-coated finish Powder-coated fan guard Full louvered panel to protect coil Formed base with 21.2" ground clearance Limited 5-year warranty on parts Low pressure port Integrated solid state control with adjustable time-temp demand defrost Easy To Install: Factory-charged Only three screws to access electrical controls Easy access to service valves Rated in Accordance with ARI Standard 210/240. Certification Applies Only When Used with Proper Components as Listed with ARI. Additional rating information can be found at Residential & Light Commercial HVAC Model Number Size (tons) Refrigerant Nominal BTUH Min. Circuit Ampacity 2Max. Fuse or Breaker Operating Dimensions H x W x D (inches) Min. Mounting Pad Size (inches) Ship / Operating Weight (lbs) CH18ABD1VF 1 1.2 R-22 18,000 13.5 20 32 1.2 X 21 1.2 X 21 1.2 24 x 24 132 / 127 CH24ACD1VF 2 R-22 24,000 16.0 25 32 1.2 X 29 1.2 X 29 1.2 32 x 32 195 / 186 CH30ACD1VF 2 1.2 R-22 30,000 18.8 30 32 1.2 X 29 1.2 X 29 1.2 32 x 32 195 / 186 CH36ACD1VF 3 R-22 36,000 20.5 35 32 1.2 X 29 1.2 X 29 1.2 32 x 32 197 / 188 CH42ACD1VF 3 1.2 R-22 42,000 24.8 40 32 1.2 X 29 1.2 X 29 1.2 32 x 32 208 / 201 CH48ACD1VF 4 R-22 48,000 27.3 45 32 1.2 X 29 1.2 X 29 1.2 32 x 32 212 / 203 CH60ACZ1VF 5 R-410A 60,000 38.4 60 39 X 29 1.2 X 29 1.2 32 x 32 258 / 249 Product Specifications PHYSICAL DATA MODEL SIZE 18 24 30 36 42 48 60 PERFORMANCE DATA NOMINAL CAPACITY (BTUH) 18,000 24,000 30,000 36,000 42,000 48,000 60,000 FAN DATA FAN MOTOR TYPE PSC PSC PSC PSC PSC PSC PSC HP 1/5 1/3 1/3 1/3 1/3 1/3 1/3 DIAMETER 18" 22" 22" 22" 22" 22" 24" BLADE 3 3 3 3 3 3 3 RPM 1,050 1,050 1,050 1,050 1,050 1,050 950 CFM 1,800 3,400 3,400 3,400 3,400 3,400 4,000 OUTDOOR COIL TYPE Enhanced Aluminum Plate Fin / Ri...

Otros modelos de este manual:
Equipos de Bombeo - CH24ACD1VF (131.37 kb)
Equipos de Bombeo - CH30ACD1VF (131.37 kb)
Equipos de Bombeo - CH36ACD1VF (131.37 kb)
Equipos de Bombeo - CH42ACD1VF (131.37 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría