Iniciar sesión:
Votos - 2, Puntuación media: 3 ( )

Manual de usuario Genie, modelo TMZ-34/19

Fabricar: Genie
Tamaño del archivo: 513.44 kb
Nombre del archivo: 97866.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Component damage may also result if problems are not discovered and repaired in a timely fasion. 1 Check the tire surface and sidewalls for cuts, cracks, punctures and uneven or excessive tread wear. Result: Replace the tire if uneven or excessive tread wear is found. Always replace the tire with specifications equal to original equipment manufacturer. 2 Check each wheel for damage, bends and cracks. Result: Replace the wheel if any damage is found. 3 Check each tire with an air pressure gauge and add air as needed. MAINTENANCE 4 Check the torque of each lug nut. Tires and wheels - ANSI & CSA Tire size ST195/75D14 Lug nut torque 80 ft-lbs 108 Nm Tire pressure (cold) 65 psi 4.5 bar Tires and wheels - CE Tire size 195/65R15 91T Lug nut torque 80 ft-lbs 108 Nm Tire pressure (cold) 44 psi 3.0 bar Part No. 97866 Genie TMZ-34/19 Operator's Manual Fourth Edition • First Printing MAINTENANCE Check the Batteries Proper battery condition is essential to good performance and operational safety. Improper fluid levels or damaged cables and connections can result in component damage and hazardous conditions. This procedure does not need to be performed on machines with sealed or maintenance-free batteries. Bodily injury hazard. Batteries contain acid. Avoid spilling or contacting battery acid. Neutralize battery acid spills with baking soda and water. 1 Put on protective clothing and eye wear. 2 Be sure that the battery cable connections are tight and free of corrosion. 3 Be sure that the battery hold-down brackets are secure. 4 Remove the battery vent caps. 5 Check the battery acid level. If needed, replenish with distilled water to the bottom of the battery fill tube. Do not overfill. 6 Install the vent caps. Scheduled Maintenance Maintenance performed quarterly, annually and every two years must be completed by a person trained and qualified to perform maintenance on this machine according to the procedures found in the service manual for this machine. Machines that have been out of service for more than three months must receive the quarterly inspection before they are put back into service. Genie TMZ-34/19 Part No. 97866 Fourth Edition • First Printing Operator's Manual Do Not Operate Unless: You learn and practice the principles of safe machine operation contained in this operator's manual. 1 Avoid hazardous situations. 2 Always perform a pre-operation inspection. 3 Always perform function tests prior to use. Know and understand the function tests before going on to the next section. 4 Inspect the workplace. 5 Only use the machine as it was intended. Function Tests Fundamentals The function tests are designed to discover any malfunctions before the machine is put into service. The operator must follow the step-by-step instructions to test all machine functions. A malfunctioning machine must never be used. If malfunctions are discovered, the machine must be tagged and removed from service. Repairs to the machine may only be made by a qualified service technician, according to the manufacturer's specifications. After repairs are completed, the operator must perform a pre-operation inspection and function tests again before putting the machine into service. Set up 1 Position the machine directly below the desired work area. 2 Set the parking brake. 3 Disconnect the trailer lights, chains and surge brake safety cable from the vehicle. 4 Open the latch on the ball coupler. 5 Pull the jack release handle and rotate the tongue jack to the lifting position. 6 Raise the tongue by turning the jack handle. 7 Open all boom hold-down latches. 8 Release the jib hold-down straps (if equipped). Part No. 97866 Genie TMZ-34/19 Operator's Manual Fourth Edition • First Printing FUNCTION TESTS Note: Perform the appropriate function tests for your control system. Determine whether the control panels on your machine match the ones below or the ones on page 22. Follow the step-by-step instructions below the pictures to test all machine functions. Platform Control Panel Ground Control Panels At the Ground Controls 1 Insert the key and turn to ground control. 2 Pull out the red Emergency Stop buttons at the ground and platform controls. Machines with LED diagnostic readout: LED should read ----. Note: Machines with LED diagnostic readout perform a self-check when the power is turned on. The self-check takes about 5 seconds. Do not touch the buttons of the ground control panel until the self-check is done. 3 Models with manual outriggers: Select an outrigger. Maintain a firm grasp on the outrigger. Pull the outrigger release handle and lower the outrigger. Be sure the outrigger lock pin is locked. Repeat the procedure for each of the remaining outriggers. Adjust the outriggers to level the machine and raise the wheels slightly off the ground. Level the machine using only the leveling jacks. Models with hydraulic outriggers: Push and hold the auto-level button. Push and hold the extend outrigger button. The outriggers will lower and adjust to...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría