Iniciar sesión:
Votos - 2, Puntuación media: 3.5 ( )

Manual de usuario Starmax Resource, modelo STARMAX 9820

Fabricar: Starmax Resource
Tamaño del archivo: 25.28 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Once you are ready to collimate, look into rear opening of the tube. If your telescope is out of collimation, it will resemble Figure 2a, a properly collimated scope will resemble Figure 2b. The direction of the misalignment in your telescope may differ from Figure 2a, but the diagram will give you the general idea of how things will look. Note there are six alignment screws on the back of the optical tube, three large and three small.You will need 3mm and 2mm Allen wrenches to turn these screws. These alignment screws push and pull the mirror cell in order to tilt it. When you loosen or tighten one of these screws, the other five screws must be adjusted as well to keep the proper amount of pressure on the back of the mirror cell. By making slight adjustments to how much the screws are tightened and loosened, you will change the alignment of the primary mirror. Look into the rear opening of the tube and locate the black crescent that shows the telescope is out of alignment. (Figure 2a). Note which way the front of the telescope would need to move in order to “fill” that black crescent and resemble Figure 2b. Then look at the back end of the telescope and locate the alignment screw that is in the direction that the Figure 2b: With the optics properly aligned the view through the rear opening of the telescope will resemble Figure 2b. front of the telescope needs to move. For example, if the view in your telescope resembled Figure 2a, then you would want to move the front opening of the telescope scope to the right. Then the alignment screw you would start with would be the screw on the right as shown in Figure 3. Your actions now depend on whether this alignment screw is a small or large screw. Please note that you will be working to adjust the mirror cell by keeping all the screws not too loose and not too tight. Follow the steps listed below carefully and refer to the figures that accompany them. Figure 3: If the view through Figure 3 the rear opening of the telescope resembled Figure 2a, then the alignment screw you would start with would be this one. The actual first alignment screw you would pick will vary depending on which way the front opening would need to move in order to “fill” the black crescent. Figure 4a Figure 4cFigure 4b Figure 4d Figure 4a Figure 4cFigure 4b Figure 4d Figure 4a: Using the 3mm Figure 4b: Now, with the Allen wrench, turn the large 2mm Allen wrench, turn the screw clockwise a small two adjacent small screws amount, no more than 1/4 of counterclockwise no more a turn. (Note, actual selected than 1/4 turn. alignment screw will vary.) If the alignment screw is a large screw First, using the 3mm Allen wrench, turn the large screw clockwise a small amount, no more than a 1/4 turn. (Figure 4a) Now, with the 2mm Allen wrench turn the two adjacent small screws (Figure 4b) counterclockwise no more than 1/4 turn. Locate the small screw that is 180° opposite the first screw (Figure 4c) and turn it clockwise no more than 1/4 turn...

Otros modelos de este manual:
Instrumentos de óptica - STARMAX 127 (25.28 kb)
Instrumentos de óptica - STARMAX 90 (25.28 kb)
Instrumentos de óptica - STARMAX 9823 (25.28 kb)
Instrumentos de óptica - STARMAX 9824 (25.28 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría