Iniciar sesión:
Votos - 3, Puntuación media: 4.3 ( )

Manual de usuario Amcor, modelo SD12

Fabricar: Amcor
Tamaño del archivo: 604.63 kb
Nombre del archivo: bd9379eb-1bc9-4082-bcf0-e36dbbc4f086.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


DRAINAGE The extracted water can be collected in the water container or drained continuously through a flexible hose (not supplied). Use of the water container When the drain outlet is blocked by the stopper, the extracted water will run into the water container. When the container is full, the compressor and the fan stop operating and the container full indicator [4] illuminates. • Slowly slide out the container to the side (1) or to the front (2). • Lift the container slightly by the built-in handle, then pull it out. • When, after emptying, the container is put back in place, the container full light will go off. Continuous drainage 1. Remove the stopper from the drain outlet. 2. Place a 11 mm inner diameter hose over the outlet. The other end of the hose should (without bends) end in a lower level drainage point. 3. Remove the water container (empty if necessary) and put the stopper from beneath in the drain hole to the water container. Put the water container back in place. Note: in very cold conditions, precautions should be taken to prevent the drain hose from freezing. 8 CLEANING WARNING! First of all switch off the unit and pull the plug out of the wall socket. Housing Clean the housing with a soft, damp cloth and dry when clean. Never use chemically treated cloths, alcohol or any other product containing solvents as this may cause damage to the housing. Air filter This dehumidifier is equipped with a washable anti-dust filter and an odour absorbing active carbon filter. These will capture larger airborne particles like dust, smoke and animal dander, creating a less irritating living environment. Regular cleaning of the filter (once a month and after storage) prevents the build up of dust, that may block the air flow and reduce the efficient operation of the dehumidifier. • Remove the water container. • Pull out the filter holder. • Remove the black carbon filter and use a vacuum cleaner or tap the filter lightly to clean. Replace this filter if it is very dirty. Never wash the carbon filter. • Clean the plastic filter mesh with lukewarm water and a small amount of medium strength detergent. Rinse thoroughly with cold water. Make sure that the air filter is completely dry before putting it back. Do not forget to replace the carbon filter after cleaning. NOTE! Do not expose the filter to sunlight or other sources of direct heat as this may cause the filter and frame to warp. Never use the dehumidifier without the air filter. LONG TERM STORAGE If the dehumidifier is not used for long periods of time, follow these steps: • disconnect the unit and wrap the power cable. • if used, empty the water container. • clean the unit and filter, pack it in its original packaging or cover to protect against dust. • store the unit in an upright position in a cool, dry place away from access by children. 9 GBGB TROUBLE SHOOTING Never try to repair or dismantle the unit yourself. Before calling for assistance please check the points below. The unit doesn’t run. Is the machine plugged in? Is the mains power supply on? Is the water tank full indicator on? (If so, the water tank is full or it isn’t positioned properly). The unit seems to extract little water. Are too many windows or doors open? Is there something in the room producing lots of heat? Is the room cold – the colder the air the less moisture the unit will extract. Is the filter dirty? Is the room humidity already quite low? The unit seems to do nothing. Is the filter dirty? Is the air intake or outlet blocked? Is the room humidity already quite low? Is the room temperature below 5 °C? The fan may run without the compressor. Too noisy. Is the machine positioned unevenly so as to create vibration? Is the floor underneath the unit uneven or loose fitting? Is there any foreign body interfering with the unit? The unit’s fan doesn’t seem to be revolving. Is the filter blocked? Is there any foreign body interfering with the unit? The continuous drainage is not working. Does the hose have a downward slope throughout its entire length? Is there a kink or sharp bend in the hose? TECHNICAL DATA Model SD12 Power supply 220-240 V/ 50 Hz Power consumption (at 32 °C, RH 90%) W 235 Current A 1.3 Moisture removal (at 32 °C, RH 90%) L/24h 12 Refrigerant R-134A Refrigerant load g 170 Water container capacity L 4 Operating temperature range °C 5 - 35 Dimensions (width x depth x height) mm 420 x 220 x 540 Net weight kg 15 Subject to modifi cation without prior notice. For greater precision, please refer to the rating label placed on the product. 10 Hong Kong Amcor Ltd Suite 2007, Tower 6, The Gateway, Harbour City, 9 Canton Road, Tsim Sha Tsui, Kowloon, Hong Kong Tel: +852 2997 6865 Fax: +852 2997 6091 Email: amcorhk@amcorgroup.com United Kingdom Amcor Ltd 9 Ryan Drive, West Cross Centre, Great West Road, Brentford, Middlesex, TW8 9ER, United Kingdom Tel: +44 20 8560 4141 Fax: +44 20 8232 8814 Email: amcoruk@amcorgroup.com USA Amcor Inc. 685A Gotham Parkway, Carlstadt, New Yerse...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría