Iniciar sesión:
Votos - 3, Puntuación media: 4 ( )

Manual de usuario Holmes, modelo HM5600

Fabricar: Holmes
Tamaño del archivo: 164.38 kb
Nombre del archivo: 80e7284a-01ab-45bf-8107-27d93d0ef416.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


It also prevents micro-organisms from growing on the tray and tank. This ensures that maximum efficiency will be achieved. We cannot over-emphasize how essential proper cleaning is to the maintenance and continued use of your unit andto the avoidance of algae or bacteria build-up. Daily Maintenance Allow to cool before maintenance. 1. Before cleaning, set the control to OFF position and unplug the unit from the electrical outlet. 2. Remove the water tank then unlock the misting chamber by rotating the safety lock towards the front of the unit. Lift mist chamber from the unit’s base. Now lift the tray from the base. 3. Empty water and minerals from the tray and place in the top rack of the dishwasher. This will remove any sediment and dirt that has accumulated in the tray. NOTE: It is imperative that the tray is cleaned properly. The tray is dishwasher safe (top rack ONLY) for easy cleaning. 4. Wipe the heating element clean with a soft cloth after it has had a chance to cool. 5. Replace misting chamber and engage safety lock. The Electronic Thermal Control Heating element is lined with a Teflon® coating that is designed to provide the easiest cleaning and prolong the operating efficiency of the humidifier. DO NOT use any metal or hard objects to clean the Heating Element. Never use detergents, gasoline, kerosene, glass cleaner, furniture polish, paint thinner or other household solvents to clean any part of the humidifier. Figure 2 A. Removable Tray B. Water Purification Filter C. Humidifier Base A B C Weekly Maintenance Remove scale: Allow to cool before maintenance. 1. Repeat steps 1-5 in the Daily Maintenance section. 2. Clean the tray by partially filling the tray with one 8-oz cup of undiluted white vinegar. Let solution stand 20 minutes, cleaning all interior surfaces with a soft brush. Dampen a cloth with undiluted white vinegar and wipe out entire tray to remove scale. 3. Rinse with clean warm water to remove scale and the white vinegar solution before beginning to disinfect the tank. 4. Wipe the heating element clean with a soft cloth after it has had a chance to cool. Disinfect tank: 1. Fill tank with 1/2 teaspoon of chlorine bleach and 1/2 gallon of water. 2. Let the solution stand for 20 minutes, swishing every few minutes. Wet all surfaces. 3. Empty the tank after 20 minutes, and rinse well with water until the bleach smell is gone. Dry with a clean cloth or paper towel. 4. Refill the water tank with cool water; replace the housing and water tank. Repeat ALL Operating Instructions. REPLACING THE WARM MIST WATER PURIFICATION FILTER The water purification filter is used to trap minerals in your water and provide a clean moisture output. The filter life is determined by the average daily use of your humidifier and the water hardness in your area. Areas with hard water will require more frequent replacement of the filter. It is strongly recommended that the filter be replaced at least every 2-3 months (depending on use) or when the heating element is starting to gather minerals on it. Hands should be cleaned immediately after removalof filter. Keep away from eye’s and mouth. To Replace the Filter: Allow to cool before maintenance. 1. Switch the humidifier OFF and unplug. Remove the tank, drain any water from the base, lift out the used filter, and throw it away. 2. Remove the protective bag from the new filter and install the filter into the base (see Figure 2). Replace the tank, and plug the cord into the electric outlet. When installing the filter for the first time, wait 15 minutes for the water to flow through the filter before switching the unit ON. You can obtain a new filter by calling 1-800-5-HOLMES in the USA or by visiting your nearest retailer or authorized service center. This humidifier takes model WMF50 replacement filter. TROUBLESHOOTING - STORAGE FILTER ACCESSORIES TROUBLE PROBABLE CAUSE SOLUTION Power light not illuminated. "Refill/Reset" light illuminated. Mist output minimal to none. Water leaks from tank. Crack from tank. Film on tank. Unit not plugged in. Power failure. Water tank empty. Unit not reset after refill. Scale buildup in tray. Scale buildup in heating element. Scale buildup in tray or heating element. Tank rubber ring is missing or improperly placed. Cap not tight enough. Tank water hot Hot water will cause tank to pressurize. Tanks are delicate, and will crack if dropped. Mineral deposits cause film on tank to buildup. Plug in unit. Check circuit breaker or outlet. Refill tank. Switch the knob to the "OFF" position, follow manual for Reset Instructions. Remove tray and flush out residue. Remove scale from heating element. Remove scale from tray and heating element. Remove tank cap and replace or reposition ring. Tighten the cap. Tank may be damaged call 1-800-5-HOLMES Fill tank with cool water. Handle tank with care. Clean/disinfect tank as instructed in weekly cleaning instructions. To order call 1-800-5-HOLMES toll free Cloudy Water. Mineral deposits cause film o...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría