Does not defrost control. Defrost control is defective. Check defrost control, replace it. 4. Insufficient dehumidification Low relative humidity Turn dehumidifier off. Poor air circulation Move dehumidifier to obtain free and unobstructed air circulation. H/E clogged with dust and dirt Clean evaporator and/or condenser assembly Air filter is dirty. Clean it. Motor is not operating. Check Motor, repair or replace it. —18— CONDITION CAUSE REMEDY 5. Noisy operating Fan If cracked, out of balance, or partially missing, replace it Some material plunged and rattle. Remove it. Tube hits frame. Adjust tubing routine carefully. Fan blade hits frame Check Motor Mount. If loose, tighten it. Internal compressor noise. Replace compressor. Loose set screws Tighten them. Worn bearings of Motor Assembly If knocking sounds continue when running or loose, replace the motor. If the motor hums or noise appears to be internal while running, replace motor assembly. 6. Water drips The bucket is not installed properly. The bucket should be properly positioned on the hangers of the drain pan. Connection may be loose. Check connection and repair. Leak in bucket Replace bucket. Water drips when bucket removed for emptying. Before removing bucket, the unit should be turned off. Bucket overflows. Check micro switch and float. 7. Compressor cycles on overload protector. (O.L.P.) High or low line voltage. (115V ± 10%) Check line voltage. It must be between 103.5V and 126.5V volts. If intermittent, provide new supply. Poor air circulation. Move dehumidifier for free and unobstructed air flow. Heat Exchange clogged with dust or dirt. Clean dust or dirt on the Heat Exchange. Motor If not running, determine the cause. Replace if required. Bad P.T.C. assembly (if assembled) Check P.T.C., Repair. Short circuit or ground in electrical circuit Check electrical circuit. Repair. Unit pressures not equalized Allow 2 or 3 minutes for pressure to equalize before starting compressor. Capacitor Test the capacitor. Wiring Check the terminals. If loose, repair or replace. Refrigeration system Check the system for a restriction. Stuck compressor Check compressor, replace compressor Overload protector (O.L.P.) Check O.L.P., if externally mounted. Replace if open. (If the compressor temperature is high, remove the O.L.P., cool, and retest.) —19— 5. EXPLODED VIEW - INTRODUCTION • MODEL: DH3010B/DHA3012DL —20— 266011 269120 266140 266003 252160 149410 135312 264110 249950 W6640 152302 147910 550140 554030 552111 130900 130411 354211 148380 346811 349600 549990 359012 352113 667482 35211A 567502 554160 —21— • MODEL: DH4010B/DHA4012DL, DH5010B/DHA5012DL(DEFROST CONTROL TYPE) 269130 266003 252160 149410 135312 264110 W0CZZ 152302 147910 266011 567502 554160 550140 554030 552111 130900 130411 354211 148380 346811 349600 549990 359012 352113 35211A 249950 —22— • MODEL: DH4010B/DHA4012DL, DH5010B/DHA5012DL(THERMOSTAT CONTROL 149410 135312 152302 147910 266011 567502 554160 550140 554030 552111 130900 130411 354211 148380 346811 349600 549990 359012 352113 35211A 269120 266003 252160 264110 249950 269310 W0CZZ 6. REPLACEMENT PARTS LIST • MODEL: DH3010B, DHA3012DL LOCATION NO. DESCRIPTION PART NO. REMARKDH3010B/DHA3012DL 130411 BASE ASSY, WELD(SINGLE) 3041AD2007B 130900 CABINET 3090A10001J 135312 GILLE ASSY, FRONT 3531A20012B 147910 BARRIER ASSY 4791A10002B 148380 TANK, BUCKET 4838A20005A 149410 KNOB ASSY 4941A30002A 152302 FILTER(MECH), AIR 5230AD3005A 249950 CONTROL BOX ASSY 4995A20085F W6640 TERMINAL BLOCK 6640A40001A 264110 POWER CORD ASSY 6411A20001Q ALT) 6411A20001R 266003 SWITCH, ROTARY 6600A20001A 252160 HUMIDISTAT 5216A20001A ALT) 5216A20001B 266011 SWITCH ASSY, MICRO 6600A30003C 266140 CONTROL DEFROST 6614A30001H 269120 LAMP, NEON 6912A30001F 346811 MOTOR ASSY, SINGLE 4681A20040A 35211A TUBE ASSY, SUCTION SINGLE 5211A30373B 352113 TUBE ASSY, DISCHARGE SINGLE 5211A30367A 354211 EVAPORATOR ASSY 5421A10009B 549990 SHROUD ASSY 4999A10001A 550140 ISOLATOR 5040AR4195A 552111 TUBE ASSY, CAPILLARY 5211A10085C 554030 CONDENSER ASSY 5403A10008B 554160 COMPRESSOR ASSY, FINAL 2521C-A8605 359012 FAN, TURBO 5900A20007A 567502 O.L.P 6750C-0002S 349600 MOUNT, MOTOR 4960A20009A 667482 P.T.C 6748C-0003A —23— • MODEL: DH4010B/DHA4012DL, DH5010B/DHA5012DL(DEFROST CONTROL TYPE) LOCATION NO. DESCRIPTION PART NO. REMARK DH4010B/DHA4012DL DH5010B/DHA5012DL 130411 BASE ASSY, WELD(SINGLE) 3041AD2007C 130900 CABINET 3090A10001J 135312 GILLE ASSY, FRONT 3531A20012B 147910 BARRIER ASSY 4791A10002A ALT)4791A10002B 148380 TANK, BUCKET 4838A20005A 149410 KNOB ASSY 4941A30002A 152302 FILTER(MECH), AIR 5230AD3005A W0CZZ CAPACITOR 0CZZA20001Q 249950 CONTROL BOX ASSY 4995A20085E 264110 POWER CORD ASSY 6411A20001Q ALT) 6411A20001R 266003 SWITCH, ROTARY 6600A20001A 252160 HUMIDISTAT 5216A20001A ALT) 5216A20001B 266011 SWITCH ASSY, MICRO 6600A30003C 266140 CONTROL DEFROST -6614A30001F 269120 LAMP, NEON 6912A30001F 346811 MOTOR ASSY, SINGLE 4681A20040A 35211A TUBE ASSY, SUCTION SINGLE 5211A10071...

Otros modelos de este manual:
Los deshumidificadores - DH3010B (1.35 mb)
Los deshumidificadores - DHA3012DL (1.35 mb)
Los deshumidificadores - DHA4012DL (1.35 mb)
Los deshumidificadores - DHA5012DL (1.35 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría