Manual de usuario Bryant, modelo HUMBBWBP2417

Fabricar: Bryant
Tamaño del archivo: 262.5 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


HN61KQ120 2 DIMENSIONS Model HUMBBLBP2417 & HUMBBWBP2417 Model HUMBBLFP1418 10.25 (260) (457) DUCT CUT-OUT SIZE W x H 16.0 (406) 14.81 x 14.25 (376 x 362) Model HUMBBSBP2412 14.0 (356) Damper "Season" Selector Built-In Bypass Damper SUMMERSUMMERWINTER DUCT CUT-OUT SIZE W x H 9.50 x 9.50 (241 x 241) 10.25 (260) 13.0 (330) 5.68 (144) 10.25 (260) 15.75 (400) 5.68 14.0 (356) Damper "Season" Selector Built-In Bypass Damper SUMMERSUMMERWINTER (144) DUCT CUT-OUT SIZE W x H 9.88 x 12.75 (251 x 324) Model HUMBBSFP1016 DRAIN 12 (305) 12.5 (318) WATER INLET OPTIONAL WATER VALVE MOUNTING 115V PLUG CORD FRONT ACCESS COVER A08384 10.18 SIDE DOOR 24VAC (259) HUM 3 RECOMMENDED RELATIVE HUMIDITY BY OUTDOOR TEMPERATURE OUTDOOR TEMP OUTDOOR RELATIVE HUMIDITY INDOOR RELATIVE HUMIDITY _F(_C) (%) (%) W/O HUMIDIFIER* 1to2 2to4 3to6 4to10 30(- ---1) 30to70 6to15 ---10(---23)30to700(---18)30to7010(---12)30to7020(---7)30to70 * Indoor relative humidity level when outdoor air is heated to 72_F/22_C. { As stipulated by the Air Conditioning Contractors of America. MAX RECOMMENDED INDOOR RELATIVE HUMIDITY{ 20 (Lo) 25 30 35 40 (Med) INDOOR RELATIVE HUMIDITY LIMIT FOR NO WINDOW CONDENSATION HUM (Indoor Air at 74_F/23_CDry Bulb) SINGLE PANE WINDOWS (%) 39 29 21 15 10 7 5 ---30 (---34) 3 OUTDOORTEMPERATURE_F(_C) 40(4) 30(---1) 20(---7) 10(---12) 0(---18) ---10(---23) ---20(---29) MAXIMUM MOISTURE REQUIREMENTS* VOLUME OF RESIDENCE TIGHT HOUSE CUBIC FEET POUNDS GALLONS (LITERS) (CUBIC METER) DOUBLE PANE WINDOWS (%) 59 50 43 36 30 26 21 17 AVERAGE HOUSE POUNDS GALLONS (LITERS) (KILOGRAMS) PER PER DAY (KILOGRAMS) PER PER DAY HOUR HOUR 3.52 (1.6) 10.17 (38) 4.41 (2.0) 12.72 (48) 5.29 (2.4) 15.26 (58) 5.92 (2.7) 17.08 (65) 7.06 (3.2) 20.35 (77) 7.94 (3.6) 22.89 (87) 8.82 (4.0) 25.44 (96) 9.71 (4.4) 27.98 (106) 10.59 (4.8) 30.52 (116) 11.47 (5.2) 33.07 (125) 12.35 (5.6) 35.61 (135) 30,000 (850) 6.62 (3.0) 19.08 (72) 13.24 (6.0) 38.16 (144) 8,000(227)1.76(0.8)5.09(19) 10,000(283)2.21(1.0)6.35(24) 12,000(340)2.64(1.2)7.63(29) 14,000(396)3.09(1.4)8.91(34) 16,000(453)3.53(1.6)10.18(39) 18,000(510)3.97(1.8)11.45(43) 20,000(566)4.41(2.0)12.72(48) 22,000(623)4.85(2.2)13.99(53) 24,000(680)5.29(2.4)15.27(58) 26,000(736)5.74(2.6)16.54(63) 28,000(793)6.18(2.8)17.81(67) * Based on design conditions of outdoor 20_F/---7_C dry bulb, 80% RH; indoor 70_F/21_C dry bulb, 40% RH, and minimum moisture production from residential operations for an absolute humidity difference of 0.0049 lb/hr. NOTE: Tight house is defined as being well insulated, having vapor barriers, tight storm doors and windows with weatherstripping, and having dampered fireplaces. Average house is defined as being insulated, having vapor barriers, loose storm door and windows and having dampered fireplace. 4 5 TYPICAL HUMIDIFIER INSTALLATIONS DOWNFLOW HORIZONTAL Built-in Bypass Damper Built-in Bypass Damper UPFLOW UPFLOW *Note - It is recommended that hot water be supplied in this return air application. * UPFLOW Built-in Bypass Damper A...

Otros modelos de este manual:
Los deshumidificadores - HUMBBSBP2412 (262.5 kb)
Los deshumidificadores - HUMBBLBP2417 (262.5 kb)
Los deshumidificadores - HUMBBLFP1418 (262.5 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría