This dehumidifier should not be used for commercial or industrial applications. Place the dehumidifier on a smooth, level floor strong enough to support the unit with a full bucket of water. Allow at least 20cm of air space on all sides of the unit for good air circulation. Place the unit in an area where the temperature will not falll delow 5 C(41 F). The coils can become covered with frost at temperatures below 5 C(41 F), which may reduce performance. Place the unit away from the clothes dryer, heater or radiator. Use the unit to prevent moisture damage anywhere books or valuables are stored. Use the dehumidifier in a basement to help prevent moisture damage. The dehumidifier must be operated in an enclosed area to be most effective. Close all doors, windows and other outside openings to the room. Fig.4 7 CARE AND MAINTENANCE Removing the collected water 1. Pull out the bucket a little. 2. Hold both sides of the bucket with even strength, and pull it out from the unit. 3. Pour the water out. There are two ways to remove collected water. 1. Use the bucket When the bucket is full, the unit will automatically stop running, and the Full indicator light will flash. Slowly pull out the bucket. Grip the left and right handles securely, and carefully pull out straight so water does not spill. Do not put the tank on the floor because the bottom of the bucket is uneven. Otherwise the bucket will fall and cause the water to spill. Throw away the water and replace the bucket. The bucket must be in place and securely seated for the dehumidifier to operate. The machine will re-start when the bucket is restored in its correct position. NOTES: When you remove the bucket, do not touch any parts inside of the unit. Doing so may damage the product. Be sure to push the bucket gently all the way into the unit. Banging the bucket against anything or failing to push it in securely may cause the unit not to operate. NOTE: When the continuous drain feature is not being used, remove the drain hose from the connector and attach the back drain hole with the rubber plug shown in Fig.1. Remove the water bucket from the front of the unit, you will find a section of hose located above the bucket. Remove the rubber plug from the back of the unit and store it in a safe location(see Fig.8). Insert the water hose through the hole in the back of the unit and securely press it onto the connector on the front of the unit(see Fig.9). Then lead the water hose to the floor drain or a suitable drainage facility. Replace the bucket in the unit. The bucket must be in place and securely seated. 2. Continuous draining Water can be automatically emptied into a floor drain by attaching the unit with a water hose (not included). Remove the rubber plug Push the hose into the drain hole Fig.5 Fig.6 Fig.7 Fig.8 Connector Fig.9 Drain hose 8 3. Clean the air filter The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary. NOTE: DO NOT RINSE OR PUT THE FILTER IN AN AUTOMATIC DISHWASHER. To remove: Grip the tab on the filter and pull it out as shown in Fig.A. Clean the filter with warm, soapy water. Rinse and let the filter dry before replacing it. Do not clean the filter in a dishwasher. To attach: Insert the air filter into the unit from the side and push it in. See Fig.C CAUTION: DO NOT operate the dehumidifier without a filter because dirt and lint will clog it and reduce performance. Fig. A Fig. B Fig. C After turning off the unit, wait one day before emptying the tank. Clean the main unit, bucket and air filter. Wrap the cord and bundle it with the band or twist the excess cord onto the power cord hook(depending on models). Cover the unit with a plastic bag. Store the unit upright in a dry, well-ventilated place. Band Power cord 4. When not using the unit for long time periods CARE AND MAINTENANCE Care and cleaning of the dehumidifier Turn the dehumidifier off and remove the plug from the wall outlet before cleaning. 1. Clean the Grille and Case Use water and a mild detergent. Do not use bleach or abrasives. Do not splash water directly onto the main unit. Doing so may cause an electrical shock, cause the insulation to deteriorate, or cause the unit to rust. The air intake and outlet grilles get soiled easily, so use a vacuum attachment or brush to clean. 2. Clean the bucket Every few weeks, clean the bucket to prevent growth of mold, mildew and bacteria. Partially fill the bucket with clean water and add a little mild detergent. Swish it around in the bucket, empty and rinse. NOTE: Do not use a dishwasher to clean the bucket. After clean, the bucket must be in place and securely seated for the dehumidifier to operate. Thinner No Household Drain Cleaner TROUBLESHOOTING TIPS Before calling for service, review the chart below first yourself. Problem What to check Dehumidifier does not dry the air as it should Unit does not start Make sure the dehumidifier s plug is pushed completely into the outl...

Otros modelos de este manual:
Los deshumidificadores - MDF-70AE (3.26 mb)
Los deshumidificadores - MDF-50AE (3.26 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría