DMX DATA CABLE Use a Belden© 9841 or equivalent cable which meets the specifications for EIA RS-485 applications. Standard microphone cables cannot transmit DMX data reliably over long distances. The cable will have the following characteristics: 2-conductor twisted pair plus a shield Maximum capacitance between conductors – 30 pF/ft. Maximum capacitance between conductor and shield – 55 pF/ft. Maximum resistance of 20 ohms / 1000 ft. Nominal impedance 100 – 140 ohms Text Box: The fuse is located inside this Rounded Rectangular Callout: The fuse is located inside this compartment. Remove using a flat head screwdriver. 3 Resistance 120 ohm 1/4w between pin 2 (DMX -) and pin 3 (DMX +) of the last fixture. CABLE CONNECTORS CABLE CONNECTORS Cabling must have a male XLR connector on one end and a female XLR connector on the other end. Cabling must have a male XLR connector on one end and a female XLR connector on the other end. CAUTION Do not allow contact between the common and the fixture’s chassis ground. Grounding the common can cause a ground loop, and your fixture may perform erratically. Test cables with an ohm meter to verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other. CAUTION Do not allow contact between the common and the fixture’s chassis ground. Grounding the common can cause a ground loop, and your fixture may perform erratically. Test cables with an ohm meter to verify correct polarity and to make sure the pins are not grounded or shorted to the shield or each other. 3-PIN TO 5-PIN CONVERSION CHART 3-PIN TO 5-PIN CONVERSION CHART Note! If you use a controller with a 5 pin DMX output connector, you will need to use a 5 pin to 3 pin adapter. CHAUVET Model No: DMX5M, or DMX5F. The chart below details a proper cable conversion: Note! If you use a controller with a 5 pin DMX output connector, you will need to use a 5 pin to 3 pin adapter. CHAUVET Model No: DMX5M, or DMX5F. The chart below details a proper cable conversion: 3 PIN TO 5 PIN CONVERSION CHART 3 PIN TO 5 PIN CONVERSION CHART Conductor Conductor 3 Pin Female (output) 3 Pin Female (output) 5 Pin Male (Input) 5 Pin Male (Input) Ground/Shield Pin 1 Pin 1 Data ( - ) signal Pin 2 Pin 2 Data ( + ) signal Pin 3 Pin 3 Do not use Do not use Do not use Do not use COMMON DMX+ 2 Termination reduces signal errors. To avoid signal transmission problems and interference, it is always advisable to connect a DMX signal terminator. DMX connector configuration This drawing provides a general illustration of the DMX Input/Output panel of a lighting fixture. Universal DMXController Continue the link Rounded Rectangular Callout: Resistance 120 ohm 1/4w between pin 2 (DMX -) and pin 3 (DMX +) of the last fixture. Setting up a DMX Serial Data Link 1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector of the controller. 2. Connect the end of the cable coming from the controller which will have a (female) 3 pin connector to the input connector of the next fixture consisting of a (male) 3 pin connector. 3. Then, proceed to connect from the output as stated above to the input of the following fixture and so on. CHAUVET Certified DMX Data Cables Order Code Description DMX1.5 DMX Cable 1.5m/4.9ft DMX4.5 DMX Cable 4.5m/14.8ft DMX10 DMX Cable 10m/32.8ft DMX- INPUT OUTPUT 1 Text Box: This drawing provides a general illustration of the DMX Input/Output panel of a lighting fixture. 3 2 1 3 2 1 Often, the setup for Master-Slave and Standalone operation requires that the first fixture in the chain be initialized for this purpose via either settings in the control panel or DIP- switches. Secondarily, the fixtures that follow may also require a slave setting. Please consult the “Operating Instructions” section in this manual for complete instructions for this type of setup and configuration. Hanging Clamp Note! Clamp is sold separately. Master/Slave Fixture Linking 1. Connect the (male) 3 pin connector side of the DMX cable to the output (female) 3 pin connector of the first fixture. 2. Connect the end of the cable coming from the first fixture which will have a (female) 3 pin connector to the input connector of the next fixture consisting of a (male) 3 pin connector. Then, proceed to connect from the output as stated above to the input of the following fixture and so on. Rounded Rectangle: Often, the setup for Master-Slave and Standalone operation requires that the first fixture in the chain be initialized for this purpose via either settings in the control panel or DIP-switches. Secondarily, the fixtures that follow may also require a slave setting. Please consult the “Operating Instructions” section in this manual for complete instructions for this type of setup and configuration. Mounting ORIENTATION This fixture may be mounted in any position provided there is adequate room for ventilation. RIGGING It is important never to obstruct the fan or vents pathway. Mount the fixture us...