Manual de usuario Cooper Lighting, modelo E4RPINSR

Fabricar: Cooper Lighting
Tamaño del archivo: 550.6 kb
Nombre del archivo: 65e2aa55-db1b-4661-8a2b-4689de136e9b.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Captive nail penetrates standard and engineered lumber. Mounting flange levels platform with ceiling. Integral clip attaches directly to t-bar. Splay Diecast aluminum splay has truncated paramid with regressed square aperture and integral glass lens. Lens can be removed to facilitate painting to match ceiling finish. Mousetrap type springs pull flange tight to ceiling. Light trap eliminates spill light at edge of flange. Provided with both straight and angle cut parabolic shielding cone, shipped with angle cut version installed. Junction Box (7) 1/2" trade size pry outs, (3) integral clamps for non-metallic cable. Rated for (4) #12 thru branch circuits. Wago® type push wire connectors for field connections Thermal Protector Self-resetting thermal protector protects against improper lamping. Transformer Integral dual output toroidal magnetic transformer, 120V 50/60Hz input, 12V nominal 75VA maximum output. Separate output for circuits controlled by dimmers compensates for losses in dimmers, improves color temperature and lumen output. Lamp Capsule Ceramic GX5.3 lamp holder mounts to an aluminum heat sink to dissipate heat. Connects to the transformer with electrical quick connects. Accepts 2 lenses, filters or optional lamp snoot. Code Compliance Thermally protected, IP labeled, cULus listed for wet locations and ASTM-E283 AIRTITE(tm). Suitable for direct contact with insulation. jK P408ICAT MV4MR E4RPINSR 50W MR16 Tungsten-Halogen 2 Inch Square Lens Downlight ENERGY DATA LampWattage Input Power Input Current (Nominal) (Watts) (Amps) 20 21 0.17 35 37 .031 37 39 0.32 42 44 0.37 50 53 0.44 ORDERING INFORMATION: Complete unit consists of platform, lamp module and optical element. Platform P408ICAT Lamp Module Optical Element Flange Accessories MV4MR I P408ICAT = 4" Square I Aperture IC Housing MV4MR = MR16 Vertical Lamp Module, 120V Input E4RPINSR = 2" Square Aperture Regressed Pinhole, Lens I [Blank] = Self Flanged, | Matte White Flange LSA16 = Matte black lamp snoot accessory L Series - Filter Media For MR16 lamps (See Accessories specification sheet) COOLER Lighting Specifications and Dimensions subject to change without notice. ADI070186 Consult your representative for additional options and finishes. 02/29/2008 9^9^4 AM P408ICAT MV4MR E4PINSR Photometries Photometric Results Candlepower Distribution Cone of Light Candelas Spacing Criterion = .1 Efficiency = 38.3% Test No. P10515 Platform = P408I CAT Element = E4RPINSR Lumens = 575 Lamp = 42MR16 VNSP9 □ D FC Beam D 8'0" 119 1.1 9'0" 94 1.2 10'0" 76 1.3 13'0" 45 1.7 15'0" 34 2.0 Vertical Angle CD 90 0 85 0 75 0 65 0 55 0 45 1 35 4 25 16 15 103 5 2514 0 7625 Coefficients of Utilization Zonal Lumens Summary Ceiling Wall % RCR 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 Zone Lumens % Lamp % Luminaire Zonal cavity method -- floor reflectance = 20% 0 46 46 46 46 44 44 44 44 43 43 43 41 41 41 39 39 39 38 0- 30 217 37.7 98.6 1 44 44 43 43 44 43 43 42 42 41 41 40 40 40 39 39 38 38 2 44 42 42 41 43 42 41 40 41 40 40 40 39 39 39 38 38 38 0- 40 220 38.2 99.9 3 43 41 40 40 42 41 40 39 40 39 39 39 39 38 38 38 38 37 4 42 41 39 39 41 40 39 38 39 39 38 39 38 38 38 38 37 37 0- 60 220 38.3 100 5 41 40 39 38 41 39 38 38 39 38 37 38 38 37 38 37 37 37 6 41 39 38 37 40 39 38 37 38 38 37 38 37 37 38 37 37 36 0- 90 220 38.3 100 7 40 39 38 37 40 38 37 37 38 37 37 38 37 36 37 37 36 36 8 40 38 37 36 39 38 37 36 38 37 36 37 37 36 37 36 36 36 90-180 0 0 0 9 39 38 37 36 39 38 37 36 37 36 36 37 36 36 37 36 36 35 10 39 37 36 36 39 37 36 36 37 36 36 37 36 36 37 36 35 35 0-180 220 38.3 100 Photometric Results Candlepower Distribution Cone of Light Spacing Criterion = .2 Efficiency = 36.3% Test No. P10537 Platform = P408ICAT Element = E4RPINSR Lumens = 1320 Lamp = 50MR16 IR SP10 □ Candelas D FC Beam D 8'0" 160 1.3 9'0" 126 1.5 10'0" 102 1.6 13'0" 61 2.1 15'0" 45 2.5 Vertical Angle CD 90 0 85 0 75 0 65 1 55 0 45 0 35 12 25 67 15 330 5 5202 0 10234 Coefficients of Utilization Zonal Lumens Summary Ceiling Wall % RCR 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0 Zone Lumens % Lamp % Luminaire Zonal cavity method -- floor reflectance = 20% 0 43 43 43 43 42 42 42 42 40 40 40 39 39 39 37 37 37 36 0- 30 471 35.7 98.1 1 42 42 41 40 41 41 40 40 39 39 39 38 38 37 37 37 36 36 2 41 40 39 39 40 40 39 38 38 38 37 37 37 37 36 36 36 35 0- 40 478 36.2 99.8 3 40 39 38 37 40 38 38 37 38 37 36 37 36 36 36 36 35 35 4 39 38 37 36 39 38 37 36 37 36 35 36 36 35 36 35 35 34 0- 60 479 36.3 99.9 5 39 37 36 35 38 37 36 35 36 35 35 36 35 34 35 35 34 34 6 38 36 35 34 38 36 35 34 36 35 34 35 35 34 35 34 34 33 0- 90 480 36.3 100 7 37 36 35 34 37 36 35 34 35 34 34 35 34 33 35 34 33 33 8 37 35 34 33 37 35 34 33 35 34 33 34 34 33 34 33 33 33 90-180 0 0 0 9 36 35 34 33 36 35 34 33 34 33...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría