FOR USE IN THE U.S. AND CANADA. SUITABLE FOR INSTALLATION IN MOBILE HOMES IF THIS HARMAN STOVE IS NOT PROPERLYINSTALLED, A HOUSE FIRE MAY RESULT. FOR YOUR SAFETY, FOLLOW INSTALLATION DIRECTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA. CONTACT YOUR LOCAL AUTHORITY (SUCH AS MUNICIPAL BUILDING DEPARTMENT, FIRE DEPARTMENT, FIRE PREVENTION BUREAU, ETC.) TO DETERMINE THE NEED FOR A PERMIT. CETTE GUIDE D'UTILISATION EST DISPONIBLE EN FRANCAIS. CHEZ VOTRE CONCESSIONNAIRE DE HARMAN STOVE COMPANY. SAVE THESE INSTRUCTIONS. Installation & Operating Manual “Ce manuel est disponible en Francais sur demande” R5 The Harman Clarity 929 DV Direct Vent Gas Stove HARMAN 2 Manufactured by: Harman Stove Co. 352 Mountain House Road Halifax, PA 17032 INTRODUCTION ..........................................3 INSTALLATION ............................................4 Clearances ...........................................4 Venting .................................................5 Requirements for Terminating the Venting .............................................................6 Assembly .............................................7 Connecting to a Gas Supply...............9 Connecting the Cordset .................. 10 Connecting the Thermostat ............ 10 Air Shutter Adjustment ....................11 Monitoring the Gas Flame ...............11 OPERATION ............................................... 12 How to Light the Fire...................... 12 How to Turn Off the Fire ................ 12 Lighting Instructions....................... 13 MAINTENANCE......................................... 14 Removing the Glass ........................ 14 Replacing the Gasket ...................... 14 Cleaning the Glass .......................... 14 Inspecting the Venting .................... 14 Cleaning the Logset and Firebox... 14 PARTS LIST & DRAWING ................... 16-17 BURNER MODULE ...................................18 SPECIFICATIONS ......................................19 APPENDIX A: FUEL CONVERSION ....... 20 APPENDIX B: ALTITUDE DE-RATING.. 21 VENTING REFERENCE CHARTS........22-23 WARRANTY ................................................ 24 Tested by Inchcape Testing/Warnock Hersey 8431 Murphy Drive Middleton, WI 53562 CONTENTS 3 INTRODUCTION The Harman Clarity Direct Vent 929DV Gas Heater is a listed gas-fired direct vent room heater tested by Inchcape Testing/Warnock Hersey to ANSI standard Z21.88-2002, CSA 2.33-M02, and CAN/CGA-2.17-M91. The installation of the Clarity Direct Vent Gas Heater must conform with local codes, or in the absence of local codes, with National Fuel Gas Code, ANSI Z223.1 — latest edition and CAN 1 B1-149.1 and .2 Installation Code. Also for use in mobile (manufactured) homes after home is sited. Mobile (manufactured) home installations must adhere to the current edition of Title 24 CFR, part 3280, or CSA Z240.4. CAUTION: This appliance must be vented to the outside. Installation and repair of the Clarity Direct Vent Gas Heater should be done by a qualified service person. The appliance should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners, and circulating air passageways of the Clarity be kept clean. When operating your Harman Clarity Gas Heater, respect basic safety standards. Read these instructions carefully before you attempt to operate the heater. Failure to do so may result in damage to property or personal injury and may void the product warranty. Consult with your local building code agency and insurance representative before you begin your installation to ensure compliance with local codes, including the need for permits and follow-up inspections. Several issues must be addressed when selecting a suitable location for your Clarity Gas Heater. Observing required clearances to combustible materials, the proximity to a safe chimney or venting system location, and the accessibility of the gas and electrical supply must all be considered. In addition, selecting a location that takes advantage of the building's natural air flow is also desirable to maximize the heating effectiveness of the heater. In many cases, this is a central location within the building. WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. FOR YOUR SAFETY: WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Open windows. • Extinguish any open flame. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. ...