and ULC.S629 (650°C) for Canada. . This wood burning unit is only listed for installation with 6.0” diameter chimney connector and chimney systems. Installing this unit on prefabricated chimneys larger than 6.0” diameter will result in decreased draft and the potential for poor unit performance. . Follow all venting system manufacturer’s installation requirements and required clearances. . Use three sheet metal screws at each single wall chimney connector joint (check manufacturer’s recommendations when double wall chimney connector is used). . Drill three holes in the flue collar of the unit and attach the chimney connector to the unit using sheet metal screws. . Properly attach the prefabricated chimney system to the home in strict accordance with the prefabricated chimney system manufacturer’s instructions. . The overall length of the chimney connector must not exceed 8.0 ft. In the case of cathedral ceilings, the prefabricated chimney system should extend to 8.0 ft. from the top of the unit. . Special adapters and slip connectors are available to eliminate the need to cut single wall chimney connector. Double wall chimney connector must be used with these slip connectors, as it cannot be trimmed to length. Please Note: Installation diagrams are for reference purposes only and are not drawn to scale, nor meant to be used as plans for each individual installation. Please follow all venting system requirements, maintain the required clearances to combustibles, and follow all local codes. Page | 12 INSTALLATION INSTALLATION Approved Venting Method 3: Internal or External Masonry Chimney System 10 ft. Chimney liner cross.sectional area (Length x Width) must be no larger than twice the cross. sectional area of the flue collar (2x28.27in2=56.55in2). If chimney liner is larger than 56.55 in2, relining with a 5.5” or 6.0” liner is required MasonryThimblewithproperclearancetocombustiblesAshCleanoutsmusthaveanairtightsealtopreventweakdraft. .Followtheruleslistedaboveconcerningmaximumpermissiblefluelinersize;installingthisunitonmasonrychimneysexceeding56.55in2incross.sectionalareawillresultindecreaseddraftandthepotentialforpoorunitperformance. .Usethreesheetmetalscrewsateachsinglewallchimneyconnectorjoint(checkmanufacturer’srecommendationswhendoublewallchimneyconnectorisused). .Drillthreeholesinthefluecollaroftheunitandattachthechimneyconnectortotheunitusingsheetmetalscrews. .Avoidnumerouselbowsandexcessivehorizontalrunsasbothwillleadtopoordraftandincreasedcreosoteaccumulation.Horizontalrunsofchimneyconnectormustneverexceed4.0ft.andtheoveralllengthofthechimneyconnectormustnotexceed8.0ft. .Atightsealatthethimbleiscrucialforproperunitperformanceandtocreateasafeinstallation.Usetheproperadapterdesignedforconnectingsingleordoublewallchimneyconnectortoamasonrythimble. .Haveexistingmasonrychimneysinspectedforsafetyandproperclearancestocombustiblesbeforeputtingthemintoservice;aqualifiedchimneysweepcanperformthisinspection. .Externalmasonrychimneysoftensuffercolddowndraftsandpoordraftperformanceevenwhentheymeetthecross.sectionalarearules.Inthiscase,a6.0”insulatedlinermaybenecessary. Please Note: Installation diagrams are for reference purposes only and are not drawn to scale, nor meant to be used as plans for each individual installation. Please follow all venting system requirements, maintain the required clearances to combustibles, and follow all local codes. 3.0ft. 2.0ft. 18.0in. The 10.3.2 Rule: The chimney system must terminate 3.0 ft. above the point where its centerline passes through the roof AND the chimney must terminate 2.0 ft. above any part of the dwelling within a 10 ft. radius of the chimney. Chimney Connector (Single or Double Wall) Page | 13 INSTALLATION WARNING DO NOT INSTALL IN A SLEEPING ROOM. CAUTION THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALL AND CEILING/ROOF MUST BE MAINTAINED. Caution NEVER draw outside combustion air from: Wall, floor or ceiling cavity or enclosed space such as an attic, garage or crawl space. Mobile Home Installation . The wood stove MUST be secured to the floor of the mobile home using lag bolts and the holes provided in the bottom of the unit for this purpose. . The wood stove must be connected to the chimney system with double wall chimney connector which is UL listed (ULC if Canada) for use in mobile and manufactured homes. . Carefully follow all clearances listed in the appropriate section of this manual AND follow the venting manufacturer’s minimum clearance requirements. Similarly, be certain the venting system used is approved for mobile home use. . Installation must be in accordance with Manufacturers Home & Safety Standard (HUD) CFR 3280, Part 24 as well as any applicable local codes. Outside Combustion Air . The use of outside combustion air is mandatory when installing this wood stove in a mobile or manufactured home. . The outside air connection pipe protrudes from the bottom center of the stove; a kit is available from England’s Stove Works, Inc. des...
Otros modelos de este manual:Placa - TRANQUILITY 50SVL17 (1.54 mb)
Placa - TRANQUILITY 50TVL17 (1.54 mb)