Manual de usuario Cumberland Works, modelo MF3700

Fabricar: Cumberland Works
Tamaño del archivo: 3.34 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


This step is optional and not required for MF Parlor Stove to operate. Mount thermostat according to manufacturer specifications. Using a small flat head screwdriver, tighten remote thermostat wires into pins 7 and 8. See figure 19. remote thermostat terminals Figure 19: Remote Thermostat Terminals INSTALLATION AND OPERATION MANUAL Models MF3700, MF3800 Page 16 CumberlandStoveWorks.com 800-345-6007 OUTSIDE AIR CONNECTION Connection from the intake pipe (2” diameter pipe in rear of stove) to the outside of the house is REQUIRED for mobile home installation. It is recommended in tightly sealed homes with exhaust fans such as kitchen or bathroom fans. This will eliminate poor performance due to negative pressure. Only noncombustible pipes two inches (2”) or greater in diameter are approved to use for outside air connections (straight or flexible). PVC pipe is NOT approved and should NEVER be connected to the stove. If the air inlet is connected to the outside, it MUST be terminated with a vertical 90. bend (down) or with a wind hood. Failure to do so could result in a burn back during high winds blowing directly up the air inlet during a simultaneous power failure. Blockage, excessive length, or extra bends in the air intake pipe will starve the stove of combustion air. A 90. bend is equivalent in restriction to approximately 30” of straight inlet pipe. MOBILE HOME Installation in a mobile home should be in accordance with the manufactured home and safety standard. Department of Housing and Urban Development (HUD) CITE: 24CFR3280.707 stating this stove must be vented to the outside. In addition to the standard installation instructions, the following requirements are mandatory for installation in a mobile home: 1. Stove must be bolted to the floor. Stove will have four tie-down straps that bolt to the feet and the floor. 2. Stove must have an outside air source. 3. Stove must be electrically grounded to the steel chassis of the mobile home. 4. All vertical chimney vents must have wall supports. 5. All exhaust systems must have a spark arrestor. WARNING DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM. do not install in a sleeping room . Figure 22: Mobile Home Anchor & Leg Assembly CAUTION THE OPERATION OF EXHAUST FANS SUCH AS BATHROOM FANS, ATTIC FANS, ETC., MIGHT STARVE THE PARLOR STOVE OF COMBUSTIBLE AIR, CREATING A NEGATIVE PRESSURE IN THE ROOM. PROVIDE ADEQUATE VENTILATION IN THE ROOM ACCOMPANYING THE PARLOR STOVE. IF NOT, THE PRESSURE SWITCH MAY SHUT OFF OPERATION OF THE PARLOR STOVE. THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED. B C B C Tie-down Straps Lag Screw UNDERSTANDING THE TRI-X CONTROLLER 1 - On - Starts stove operation when instructed. 2 - Off - Turns off stove operation at anytime Note: Off Button will not instantly extinguish fire 3 & 4 - Temp Up, Temp Down Controls heat levels 1-6 and local thermostat temperature. 5 & 6 - Fan Up, Fan Down Controls level of convection fan (the fan that circulates warm air through the room). 7 - Add Fuel Pressing Add Fuel will turn on the feed auger. A L.E.D. light on the top right corner will be on when the auger is running. Pressing this button once will turn the auger on for one minute. If the button is pressed within the minute, the auger will then turn off. 8 - Thermostat On/Off Push to scroll through thermostat options: local, remote, or none. 9 - Scroll Allows user to change or browse heat ranges. MF3800 users have the option of running the igniter during normal operation. 10 - Enter - Chooses the top selection of the screen 1 3 5 7 9 2 4 6 8 10 Figure 23: Controller key pad. INSTALLATION AND OPERATION MANUAL Models MF3700, MF3800 800-345-6007 CumberlandStoveWorks.com Page 17 OPERATING STOVE Once the stove has been properly installed and plugged into a grounded surge protector, you are ready to begin operation. IMPORTANT: Before filling the hopper, make sure all shipping and packaging items are removed from the hopper and there are no obstructions in the auger housing opening. Your Cumberland Stove is equipped with a fuel gate in the hopper. This feature provides two important attributes to your stove: 1. If your auger mechanism requires service, the gate can be closed to allow its removal without emptying the hopper of fuel. 2. In an over-temp situation, the fuel gate will automatically close and the auger will evacuate any material in the auger housing. Once the necessary service has been performed, the fuel shutoff gate will need to be reset to open the flow of fuel to the auger. Instructions for Operating Fuel Shutoff Gate 1. To access the mechanism, remove the right side panel. To do this, first remove the air filter in the back of the stove. By placing your hands on both sides of the right side panel, lift straight up and then tilt the bottom of the panel away from the stove. Lower the panel slowly when the bottom clears the stove. Set panel aside for reinstallation. 2. To close the fuel sh...

Otros modelos de este manual:
Placa - MF3800 (3.34 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría