Verify that local building codes will permit installing the gas valve behind the range. A manual shut off valve must be installed in the gas piping, external to the appliance, for the purpose of turning on or shutting off gas to the appliance. Plan the location of the range and the gas supply to allow access to the valve when the unit is installed and in operation. Access to the remote circuit breaker panel/fuse box, with the range in place and operating, must also be allowed for in the installation. Any openings in the wall behind the appliance and in the floor under the appliance must be sealed. Both the gas supply piping and shut-off valve, and the electrical junction box/receptacle must be located so they do not interfere with the range when it is installed and under operation. In addition, the junction box must be located so the range can be removed for service when the conduit supplied with the unit is attached to the junction box. Do not lengthen the conduit or wiring provided with the range. All dimensions shown are based on standard American cabinets 36 inches (914mm) high at the finished countertop by 24 inches (610mm) deep, with a 25 inch (635mm) overall countertop depth. When installing the range into nonstandard cabinets, minimum clearances shown in the diagrams must be maintained. Carefully check the location where the range is to be installed. For best performance, the range should be placed away from drafts that may be caused by doors, windows and HVAC outlets. Cabinet and Countertop Preparation NOTES: 1. If cabinet storage space is to be provided directly above the range, the risk of personal injury may be reduced by installing a ventilating hood that projects horizontally a minimum of 5 inches (127mm) beyond the face of the cabinets. 2. The range may be installed flush to the rear wall. we recommend installing a noncombustible material on the rear wall above the range and up to the vent hood. It is not necessary to install non-combustible materials behind the range below the countertop height. 3. The minimum distance from the sides of the range above the countertop to combustible side walls must be at least 6 inches (152mm). Utilities may be located: 1. In the lower left corner of the adjacent right cabinet. (Recommended) 2. Alternate location, in the lower right corner behind the range. (Note: Some building 2 36" (914mm) Recommended 30" (762mm) Min. 25" (635mm) 30 1/16" (764mm)10" (254mm) 14" (356mm) Hood 30" (762mm) Min. 10" (254mm) Min. to combustible side walls above the range (both sides) 13" (330mm) Max. 1 10" (254mm) Top of finished counter Vertical combustible surface 18" (457mm) Min. Overall Cabinet dimension and Clearance to Combustible Surfaces departments do not permit concealing gas valves behind appliances.) Vertical non-combustible 13/32" (10mm) 29 1/4" (743mm) 30 1/16" (764mm) Contact your local building department to verify compliance with local code interpretation. Backsplash thicker than 3/4" (19mm) 1/4" (6mm) Min. flat ledge 10" (254mm) Min. 27 13/16" (706mm) 27 7/8" (708mm) Adjust for backsplash over 3/4" thick from 13/16" to 3 13/16" (21 - 97mm) surface rear wall 2 13/16" (71mm) Countertop overhangs cabinet to combustible side walls above the range (both sides) downdraft ERV30 with Slide-In, Self-Rimming Installation using 3” Side Panels ( Numbers ARSR30 and ARSL30), with Backguard Removed - Top View 1/4" (6mm) Min. flat ledge 28 11/16" (729mm) 11/16" (17mm)29 5/8" (752mm) Rear wall 25" (635mm) Adjust for backsplash thickness 13/16" to 4 1/4" (21 - 108mm) Backsplash Vertical non-combustible surface rear wall Slide-In, Self-Rimming Installation using 3” Side Panels (Part Numbers ARSR30 and ARSL30), Backguard Removed - Top View Overall dimensions RSd30 Overall dimensions (dual Fuel) Isometric View RSE30/MRES30 Overall dimensions (All Electric) Isometric View (RSE30 Shown) 4. D o not install a fuse in the neutral or ground circuit. A fuse in the neutral or ground circuit may result in an electrical shock hazard. 5. D o not ground the appliance to a gas supply pipe or hot water pipe. 6. A grounded cold water pipe must have metal continuity to electrical ground and must not be interrupted by insulating materials. Any insulating materials must be jumped with a length of No. 4 copper wire securely clamped to bare metal at both ends. Grounding Instructions (All Models) This appliance must be electrically grounded. With the range positioned directly in front of the cabinet cutout, feed the appliance conduit to the electrical junction box. Then, depending upon local codes, utilize one of the following techniques to connect the appliance to the electrical power supply: A. Connecting to a Four-Wire Electrical System. (Recommended for All Models) 1. Separate the green and white appliance wires. 2. Connect the white appliance wire to the neutral (white) supply wire in the junction box. 3. Connect the black appliance wire to the black (L1) power supply wire in the junction box. 4. C...
Otros modelos de este manual:Placa - MRES30 (935.96 kb)
Placa - Preference and Millennia RSE30 (935.96 kb)