Resumen del manual


To achieve this, the following procedure should be followed: Note - This should only be carried out when the fire is cold and unlit. •Unscrew (Anti-clockwise) the airwash control knob (Fig. 14). •Move outer cover up by tapping each end of the cover with a soft mallet. •Lift outer cover free from body, being careful not to damage the ends of each lug (Fig. 15). •Slide off the spacer tube from the centre stud and retain for re-assembly. •Unscrew the inner slider and clean/replace (Fig.16). •Refit using the reverse of this procedure. Fig. 14. Unscrew control knob Fig. 16. Inner slider removal FUEL RETAINER BARS INSPECTION Fuel retainering bars are supplied with the stove. Periodically check for any bowing or heat warpage to the fuel retaining bars and replace as necessary. Note: This operation should only be carried out when the appliance is unlit and cold. Fig. 15. Lifting cover from body Aarrow Ecoburn Wood & Multifuel Stoves SERVICING & MAINTENANCE FIRE DOOR GLASS In the event of the door glass being broken it can easily be replaced. Note: This operation should only be carried out when the appliance is unlit and cold. •The door should be lifted off the hinges so that the operations can be carried out on a workbench or similar level surface. •Unscrew the four hex bolts, on the inside of the door securing the retaining clips. •Carefully remove any pieces of broken glass, and sealing gasket wearing suitable gloves. •Re-place the gaskets and line them up in relation to the door frame. (Fig. 17) Fig. 17. Lining up the gasket •Re-seat the new glass, ensuring the sealing gasket is flat and in contact with the glass. (Fig. 18) •Replace the four retaining clips and bolts. Do not over-tighten the bolts as damage may occur to the glass (Fig.19) Re-place the door carefully over the hinges and slot in place. Fig. 19. Tightening the glass clips Fig. 18. Fitting the glass Aarrow Ecoburn Wood & Multifuel Stoves SERVICING & MAINTENANCE Date of Visit Company Work Carried Out Signature Should you have any questions about your Ecoburn stove that is not covered in this manual please contact your Aarrow Fires retailer. Please keep all repair receipts safely. Please ensure you have this manual available when an engineer visits as they will complete the service record chart. Aarrow Ecoburn Wood & Multifuel Stoves OPERATING INSTRUCTIONS FUEL TYPES Wood-Any type of wood is suitable provided it is well seasoned and has a moisture content below 20%. This usually implies that the timber has been suitably stored to allow moisture to evaporate for at least nine months in the case of soft woods, and at least eighteen months in the case of hard wood. We recommend that for general burning, wood should be split into logs of no more than 130mm (5") diameter. Larger logs can be used for overnight burning. WARNING wet wood must not be used as this will greatly contribute to the creation of tar and creosote which may, in extreme cases, run down the chimney in liquid form. This will seriously damage both the chimney and the appliance, and increase the risk of chimney fire. Note: If you have sticky tar inside the appliance or chimney your wood is 'Green' or too wet. Recommended Reading: "Wood as Fuel" available from the Forestry Commission. Peat-Can be used in turf or briquette form, but again the moisture content must be low. Paper-paper will burn successfully. Burn dry paper only or chimney damage will occur. NEVER BURN PLASTICS OR WASTE IN YOUR STOVE. Coal -Household coal produces a large amount of ash and smoke. If used the appliance and chimney will require frequent cleaning. Therefore soft house coal is not recommended. Recommended fuels are as follows: The Hetas Ltd, "Three Tick" appliance approval only covers the use of the following fuels in this appliance; Phurnacite, Phurnacite Plus, Centurion, Maxibrite, Extracite, Pureheat, Blazebrite, Taybrite, Sunbrite (Doubles/Singles), Anthracite (Large Nuts), and Welsh Dry Steam Coal (Large/Small Nuts). Approval does not cover the use of other fuels either alone or mixed with the suitable fuels listed above, nor does it cover instructions for the use of other fuels.For latest details please refer to Hetas website Do not use Homefire (six sided) and smaller sizes than Stovesse, e.g. Beans, Peas,Grains. Do not use petroleum based solid products such as Calco or Petrocoke. To do so will invalidate the appliance guarantee LIGHTING THE FIRE Prior to lighting the fire for the first time check with the installer that: •Installation and all building work is complete. •The chimney is sound and has been swept and is free from obstruction. •Adequate provision for combustion air has been made, i.e. a permanent vent of at least 550mm. per kW of rated output above 5 kW, is fitted in the room in which the appliance is installed. •That Building Regulations and any local by-laws have been followed during installation (see installation instructions). •All firebox liner panels are in place. •Throat...

Otros modelos de este manual:
Placa - EcoBurn AFS1221 (2.1 mb)
Placa - EcoBurn BK043 (2.1 mb)
Placa - EcoBurn BK043 (2.1 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría