Iniciar sesión:
Votos - 5, Puntuación media: 3.8 ( )

Manual de usuario Bertazzoni, modelo P3000RL

Fabricar: Bertazzoni
Tamaño del archivo: 4.37 mb
Nombre del archivo: 159b3265-3758-4be9-aca0-bde0aea15d07.pdf
Idioma del manual:ende
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


3 IMPORTANT SERVICE INSTRUCTIONS ....................... 3 DESCRIPTION ....................... 4 UNPACKING & WARRANTY ....................... 5 INSTALLATION NOTES ....................... 5 FRONT VIEW ....................... 6 REAR VIEW ....................... 7 INPUT A / INPUT B ....................... 7 PARALLEL CONNECTION ....................... 7 DSP OUT ....................... 7 CONTROL PORT ....................... 7 RS-232 INTERFACE ....................... 8 ADDRESS ....................... 8 REMOTE CAN-BUS ....................... 8 EASY REMOTE ....................... 9 POWER AMP OUTPUT ....................... 9 GROUND-LIFT SWITCH ....................... 9 LIMITER ....................... 10 BRIDGED MODE ....................... 10 CABLING ....................... 11 LF-CONNECTION CORDS ....................... 11 REMOTE CONTROL NETWORK ....................... 11 NETWORK EXAMPLES ....................... 12 CAN-BUS ....................... 14 CABLING SPECIFICATIONS ....................... 14 MAINS OPERATION & RESULTING TEMP ....................... 15 SPECIFICATIONS / TECHNISCHE DATEN ....................... 32 BLOCK DIAGRAM AMPLIFIER ....................... 34 BLOCK DIAGRAM RCM-24 ....................... 35 DIMENSIONS / ABMESSUNGEN ....................... 36 INHALT WICHTIGE SICHERHEITSHINWEISE ....................... 19 WICHTIGE SERVICEHINWEISE ....................... 19 BESCHREIBUNG ....................... 20 AUSPACKEN & GARANTIE ....................... 21 INSTALLATIONSHINWEISE ....................... 21 FRONTSEITE ....................... 22 RUCKSEITE ....................... 23 INPUT A / INPUT B ....................... 23 PARALLEL ....................... 23 DSP OUT ....................... 23 CONTROL PORT ....................... 23 RS-232 INTERFACE ....................... 24 ADDRESS ....................... 24 REMOTE CAN-BUS ....................... 24 EASY REMOTE ....................... 25 ENDSTUFENAUSGANGE ....................... 25 GROUND-LIFT SCHALTER ....................... 25 LIMITER ....................... 26 BRIDGED MODE ....................... 26 VERKABELUNG ....................... 27 NF-VERBINDUNGSKABEL ....................... 27 REMOTE CONTROL NETZWERK ....................... 27 NETZWERK-BEISPIELE ....................... 28 CAN-BUS ....................... 30 LEITUNGSSPEZIFIKATIONEN ....................... 30 NETZBETRIEB & WARMEENTWICKLUNG ....................... 31 SPECIFICATIONS / TECHNISCHE DATEN ....................... 32 BLOCK DIAGRAM AMPLIFIER ....................... 34 BLOCK DIAGRAM RCM-24 ....................... 35 ABMESSUNGEN ....................... 36 IMPORTANT SAFETY INSTRUCTIONS The lightning flash with arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulated „dangerous voltage“ within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintance (servicing) instructions in the literature accompanying the appliance. 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water. Do not expose this apparatus to dripping or splahing and ensure that no objects filled with liquids, such as vases, are placed on this apparatus. 6. Clean only with a dry cloth. 7. Do not block any of the ventilation openings. Install in accordance with the anufactures instructions. 8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. 9. Only use attachments/accessories specified by the manufacturer. 10. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped 11. To completely disconnect mains power from this apparatus, the power supply cord must be unplugged.. For US and CANADA only: Do not defeat the safety purpose of the grounding-type plug. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. When the provided plug does not fit into your outlet, consult an electrican for replacement of the absolete outlet. IMPORTANT SERVICE INSTRUCTIONS CAUTION: These servicing instructions are for use by qualified personnel only. To reduce the risk of electric shock, do not perform any servicing other than that ontained in the Operating Instructions unless you are qualified to do so. Refer all ervicing to qualified service personnel. 1. Security regulations as stated in the EN 60065 (VDE 0860 / IEC 65) and the CSA E65 - 94 have to be obeyed when servicing the appliance2. Use ...

Otros modelos de este manual:
Placa - P3000RL (4.37 mb)
Placa - P3000RL (4.37 mb)
Placa - P3000RL (4.37 mb)
Placa - P3000RL (4.37 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría