Iniciar sesión:
Votos - , Puntuación media: ( )

Manual de usuario Breckwell, modelo P2000

Fabricar: Breckwell
Tamaño del archivo: 685.4 kb
Nombre del archivo: P2000_2003_Manual.pdf

Idioma del manual:en

El documento se está cargando, por favor, espere
El documento se está cargando, por favor, espere

Resumen del manual


For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area. • PLEASE read this entire manual before installation and use of this pellet fuel-burning room heater. Failure to follow these instructions could result in property damage, bodily injury, or even death. • Save these instructions PROFESSIONAL INSTALLATION IS HIGHLY RECOMMENDED Manufactured by National Steelcrafters of Oregon, Inc. DBA Breckwell Hearth Products Eugene, Oregon aBRECKWELL HEARTH PRODUCTS C-L-802 8/03 Grand Prairie, Texas INTRODUCTION2 INTRODUCTION2 Thank you for purchasing the Breckwell Pellet Burning Stove. You are now prepared to burn wood in the most efficient, convenient way possible. To achieve the safest, most efficient and most enjoyable performance from your stove, you must do three things: 1) Install it properly; 2) Operate it correctly; and 3) Maintain it regularly. The purpose of this manual is to help you do all three. PLEASE read this entire manual before installation and use of this pellet fuel-burning room heater. Failure to follow these instructions could result in property damage, bodily injury or even death. Keep this manual handy for future reference. Your Breckwell P2000 comes as a fireplace insert or as a freestanding stove with a pedestal. This stove has been independently tested to ASTM E1509-95 Standard Specification for Room Heaters, Pellet Fuel Burning Type 1, UL 1482-1998 Standard for Solid Fuel Room Heaters, Oregon Administrative Rules for Mobile Homes (814-23-900 through 814-23-909) and Installation as a Stove Heater. This pellet stove, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70. This appliance is designed specifically for use only with pelletized wood. It is designed for residential installation according to current national and local building codes as a freestanding room heater. It is also approved as a mobile home heater which is designed for connection to an outside combustion air source. The stove will not operate using natural draft or without a power source for the blower systems and fuel feed system and must not be burned with any type of coal (see PROPER FUEL). This stove is designed to provide the optimum proportions of fuel and air to the fire in order to burn free of smoke and soot. Any blockage of the air supply to or from the stove will seriously degrade its performance and will be evidenced by a smoking exhaust and a sooting window. For best operation the ash content of the pellet fuel should be less than 1% and the calorific value approximately 8200 BTU/LB. Avoid high ash content fuels because this will rapidly fill up the burn pot and eventually cut off the combustion air supply. Commercial and industrial installations of Breckwell Pellet Stoves should not be used since operational control is often not well managed in these settings. IMPORTANT INFORMATION Model: _____P2000 ________________ Style: ____________________________ Serial Number:_____________________ Purchase Date: ____________________ Purchased From:___________________ ___________________ ___________________ MAIL YOUR WARRANTY CARD TODAY To receive full warranty coverage, you will need to show evidence of the date you purchased your stove. We suggest that you attach your sales invoice to this page, and fill in the form on the left, so that you will have all the information you need in one place should the need for service or information occur. SAFETY PRECAUTIONS 3 · Do not operate your stove if you smell smoke coming from it. Turn it off, monitor it, and call your dealer. · Never use gasoline, gasoline- type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or “freshen up” a fire in this stove. Keep all such liquids well away from the stove while in use. · Never block free airflow through the open vents of the stove. · Never try to repair or replace any part of the stove unless instructions are given in this manual. All other work should be done by a trained technician. · The stove will not operate during a power outage. If an outage does occur, check the stove for smoke spillage and open a window if any smoke spills into the room. · Disconnect the power cord before performing any maintenance or repairs on the stove. NOTE: Turning the stove “off” does not disconnect all power from the stove. · Do not unplug the stove if you suspect a malfunction. Turn the stove off, periodically inspect it, and call your dealer. · Contact your local building officials to obtain a permit and information on any installation restrictions or inspection requirements in your area. Notify your insurance company of this stove as well. · This unit must be properly installed to prevent the possibility of a house fire. The instructions must be strictly adhered to. Do not use makeshift methods or compromise in th...

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría