Iniciar sesión:
Votos - 4, Puntuación media: 3.3 ( )

Manual de usuario Oregon Scientific, modelo STARCK PS-M02U

Fabricar: Oregon Scientific
Tamaño del archivo: 219.18 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


The weather forecast is always displayed. Clear Partly Cloudy Cloudy Rainy TEMPERATURE AND HUMIDITY With the press of a button, you can check the current indoor or outdoor temperature, humidity percentage, comfort level, trend, and record measurements. Outdoor measurements are collected by the remote unit. 14 PS M02 English R18 op 14 7/24/03, 11:56 AM Black EN Temperature is given at the top; humidity is below. VIEW MIN / MAX / CURRENT MEASUREMENTS Press SELECT 3 times until the Temperature and Humidity Areas flash. Press UP or DOWN to scan the readings. CLEAR MIN / MAX RECORDS While viewing Min/Max records, press and hold UP or DOWN for 2 seconds until a beep sounds. This clears the previous measurements from the memory. SELECT REMOTE UNIT CHANNEL While in the Temperature / Humidity Mode, press CHANNEL to switch between CH 1, 2, or 3, or press 15 and hold CHANNEL for 2 seconds to enter Auto scan mode. If only 1 remote unit is in use, you will not be able to change channels or select Auto. If you select “Auto”, the channel will change every 3 seconds. To deactivate, press and hold CHANNEL for 2 seconds again. SENSOR SEARCHING If there is no remote unit signal, the temperature and humidity measurements will be blank. Check the remote unit batteries, or press and hold UP and DOWN for 2 seconds to search for the remote unit(s). Searching No sensor Sensor found PS M02 English R18 op 15 7/24/03, 11:56 AM Black EN NOTESignals from household electrical appliances COMFORT ZONE such as doorbells and home security systems can The indoor and outdoor comfort zones are shown for cause temporary reception failures between the indoor the following conditions. and outdoor units. This is normal and does not affect the general performance of the product. Reception will automatically resume once the interference ends. Comfort Wet Dry Zone 20 - 25 °C (68 - 77 °F) 40 - 70% Any >70% Any <40% RelativeHumidityTemperature 16 PS M02 English R18 op 16 7/24/03, 11:56 AM Black EN TRENDS The trend arrow for the last 30 minutes always displays. Indoor and outdoor temperature and humidity trends are shown separately. Trend Temperature Relative Humidity +0.5 °C +3% Steady Steady -0.5 °C -3% SET UNIT While in Temperature / Humidity Mode, press SELECT for 2 seconds. Press UP or DOWN to switch between °C and °F. Press SELECT to confirm. BACKLIGHT Press SNOOZE/LIGHT to illuminate the backlight for 5 seconds. CONTINUOUS BACKLIGHT The AC power adapter must be plugged in to use this feature ( 8). 1. The BACKLIGHT switch is located in the battery compartment. Move it to the “ON” position to enable the continuous backlight. Move it to the “OFF” position to disable. 17 PS M02 English R18 op 17 7/24/03, 11:56 AM Black EN 2. Move it to the “AUTO” position to enable continuous backlight controlled by light intensity. When activated, the backlight will be on whenever the unit perceives that the room is dark. 3. The Light Sensitivity knob switch is located in the battery compartment. Rotate to adjust. RESET ON OFF AUTO LIGHT SENSOR E OI LIGHT 4. When activated, the continuous backlight will be half as bright as usual. To achieve full brightness, press SNOOZE/LIGHT. PROJECTOR This product has a built-in projector for viewing time and alarm status at night. NOTE The maximum projection range is 2 meters (6 feet). The image gets larger the farther you display it. PROJECT TIME / ALARM STATUS In a darkened room, press SNOOZE/LIGHT to display the time and alarm status for 5 seconds. FLIP IMAGE Press SNOOZE/LIGHT again while the projector is on. ROTATE IMAGE The ROTATION switch is located on the back of the unit. Rotate to adjust. 18 PS M02 English R18 op 18 7/24/03, 11:56 AM Black EN FOCUS IMAGE The FOCUS switch is located on the back of the unit. Rotate to adjust. CONTINUOUS PROJECTION The AC power adapter must be plugged in to use this feature ( 8), Press and hold SNOOZE/LIGHT for 2 seconds when the projection is on. When activated, the time and alarm status will project continuously. Press and hold SNOOZE/LIGHT for 2 seconds again to deactivate. RESET SYSTEM The RESET buttons are located in the battery compartments for the main and remote units. Press these buttons with the tip of a blunt object (such as a ball point pen) whenever you change the batteries, or whenever performance is not behaving as expected (e.g., unable to establish radio frequency link with remote unit or automatic clock, etc.) This will return all settings to default value, and you will lose all stored information (minimum / maximum temperature and humidity, etc.). 19 PS M02 English R18 op 19 7/24/03, 11:56 AM Black EN SAFETY AND CARE Wash the unit with a slightly damp cloth and mild detergent. Avoid dropping the unit or placing it in a location where the AC power adapter will be stepped on. WARNINGS This product is designed to give you years of service if handled properly. Observe the following guidelines: • Never immerse the unit in water. This can cause electrical shock and damage the ...

Otros modelos de este manual:
Estación meteorológica - STARCK PS-M02 (219.18 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría