Iniciar sesión:
Votos - 2, Puntuación media: 3.5 ( )

Manual de usuario Omega Engineering, modelo DP1632

Fabricar: Omega Engineering
Tamaño del archivo: 1.15 mb
Nombre del archivo: M3165.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


OMEGA is constantly pursuing certification of its products to the European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct, but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, patient-connected applications. Table of Contents Rag» Section 1 - Installation - Panel-Mounting 1.1 Unpacking the Instrument 5 1.2 Installing the Instrument in the Mounting Panel 6 Section 2 - Installation - Wiring Connections 2.1 Mains (Line) Supply 8 2.2 Low Voltage (24V AC/DC) Supply - Option 8 2.3 Thermocouple Input 9 2.4 RTD Inputs 9 2.5 DC Inputs 9 2.6 Relay Outputs (Output 2 & Output 3) 9 2.7 dc Pulse Output (Output 1) 10 2.8 RS485 Communications 10 Section 3 - Front Panel 3.1 Indicators 11 3.2 Keys 11 Section 4 - Instrument Configuration 4.1 Entry into Instrument Configuration Mode 13 4.2 Parameter Sequence 13 4.3 Exit from Instrument Configuration Mode 17 Section 5 - Operation Mode 5.1 Normal Operation (Yellow LED OFF) 19 Section 6 - Instrument Setup (Yellow LED ON) 6.1 Adjustment Ranges 21 6.2 Default Values/Settings 21 Section 7 - Calibration Mode 7.1 Prerequisites 22 7.2 Entry into Calibration Mode 23 7.3 Calibration Procedure 24 7.4 Exiting Calibration Mode 25 Appendix A - Product Specification B - Order Matrix 26 31 Figures & Tables Figure 1-1 Main Dimensions 5 Figure 1-2 Panel Cut-out Dimensions 5 Figure 2-1 Rear Terminal Connections 7 Figure 2-2 Mains (Line) Supply Connections 8 Figure 2-3 Low Voltage AC/DC Supply Connections 9 Figure 2-4 RS485 Line Termination 10 Table 4-1 Sensor Selection Codes 16 Table 4-2 Output Selection Codes 16 Installation - Panel-Mounting Ir( 1.1 UNPACKING THE INSTRUMENT 1. Remove the Instrument from its packing. A panel gasket and a “no tools required” fixing strap are supplied. Retain the packing for future use (e.g. moving the Instrument to a different site). 2. Examine the delivered items for damage or deficiencies. If any are found, notify the carrier immediately. Check that the Product Code on the label affixed to the Instrument housing corresponds to that ordered. 49mm B.B.B.B. 25mm 10 mm approximately FIGURE 1-1 Main Dimensions 14 INSTALUNQ THE INSTRUMENT IN THE MOUNTING PANEL CAUTION: Do not remove the front panel gasket from the Instrument, as this may cause inadequate clamping of the Instrument to the mounting panel. Ensure that this gasket is not distorted and that the Instrument is positioned squarely against the mounting panel. Apply pressure to the front panel bezel only. Installation - Wiring Connections RS485 Comms. Relay Output 2a (Relay)3 Hw c ¡vol I a I I Output 3 Output 2b Output 1 ^,1 (Relay)* (dc Pulse) C N/C N/O — ♦ 11111« 12 11 10 » • 7 SHHHNH 000000 RTD (Pt100) Thermocouple & and DC (mV/V) DC(mA) NOTES 1. The DC (mV) input may serve as a DC (V) input using an external attenuator. 2. If the DC (mA) input is used, Terminals 2 and 4 must be linked externally. 3. Output 2a Is available only If Output 3 is not fitted. Universal Input i Line Supply ■ 24V AC Supply (Option) 12 ■ 30V DC Supply 1 (Option) FIGURE 2-1 Rear Terminal Connections NOTE: Terminals 7 & 8 are dedicated to those units which a dc Pulse output was ordered. If a single output relay unit was ordered, the relay is wired between pins 9 & 10. Function (see Table 4-2) Output Alarm 1 Alarm 2 RS485 Comms. Output 1 Output 2a 3 Output 2b 3 Output 3 3 * * * ÏÛWÆi&Mi * wm&mmà * 7 2.1 MAINS (UNE) SUPPLY This version of the Instrument will operate on a 96 - 264V AC 50/60Hz mains (line) supply. The power consumption is approximately 4W. CAUTION: This equipment is designed for installation in an enclosure which provides adequate protection against electric shock. Local regulations regarding electrical installation should be rigidly observed. Consideration should be given to prevention of access to the power terminations by unauthorized personnel. Power should be connected via a two-pole isolating switch (preferably situated near the Instrument) and a 1A fuse, as shown in Figure 2-2. FIGURE 2*2 Mains (Line) Supply Connections If the contacts of the relay output(s) are used to carry mains (line) voltage, it is recommended that the relay contacts mains (line) supply should be switched and fused in a similar manner but should be separate from the Instrument mains (line) supply. Z2 LOW VOLTAGE (24V AG/DC) SUPPLY - OPTION This version of the Instrument will operate on 12 - 24V AC 50/60Hz or 12 -30V DC supply. The power consumption is approximately 4W. The connections are shown in Figure 2-3; these should be made via a two-pole isolating switch and a 315mA slow-blow (anti-surge Type T) fuse. Neutral N 8 + FIGURE 2-3 Low Voltage AC/DC Supply Connec...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría