Manual de usuario Honeywell, modelo TE923WD

Fabricar: Honeywell
Tamaño del archivo: 300.33 kb
Nombre del archivo: fd82ffa1-cbba-4371-a264-dde67709b38b.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


• Place the remote UV sensor so that it faces the main unit (receiver), minimizing obstructions such as doors, walls and furniture. Installation The Honeywell Remote UV sensor TS704 operates at 433MHz radio frequency, so no wire installation is required between the main unit (receiver) and the remote UV sensor (transmitter). All data measured by the remote UV sensor is transmitted to the main unit wirelessly, with the operating range of 328 feet (100 meters) in the open area. Remote UV sensor must be placed outdoors to measure ultraviolet light levels. To install it: • Unscrew the lid on top of the UV sensor unit. • Remove the screw from the battery compartment door with a small Phillips screwdriver. • Insert two 2 “AA” size 1.5V batteries (not included) matching the polarities shown in the battery compartment. • Replace the battery compartment door and secure the screw. The red light from the LED indicator will flash once meaning the UV sensor works properly. • Screw the UV sensor unit lid back. •Press DOWN button either on the main unit control panel or handheld remote control. The UV reading (usually 0.00) will appear in UV window of TE923W main unit display, instead of “ - - -“. Assembly • Snap the U-shaped sensor holder onto the UV sensor unit side grooves. • Insert the round end of the U-shaped holder into the one of the mounting hardware pieces provided (ground, stake or wall). 5 Mounting There are three different options available for mounting the UV sensor: ground stand, stake and wall mount. Ground: • Insert the U-shaped sensor holder round end into the circular ground stand opening, matching 2 round holes in the opening • Secure the sensor in a location with a maximum sun exposure throughout the day. Stake: • Snap the sharp stake end onto the metal bar and secure with the screws provided. • Insert the other end of the metal bar into the U-shaped sensor holder and secure with the screws provided. • Secure the sensor in a location with a maximum sun exposure throughout the day. Wall: • Insert the wall mounting end into the metal bar and secure with the screws provided. • Snap the other end of the metal bar on to the U-shaped sensor holder and secure with the screws provided. • Secure the sensor in a location with a maximum sun exposure throughout the day. Placement tips: The UV sensor should be mounted in the area free of sunlight shadows or reflections from the nearby objects. Operation The current UV intensity is indicated in the UV window of the TE923W main unit display. It is given in the numerical value and more intuitive display, by categorizing it into the levels “LOW”, “MED”, HIGH”, V. HIGH” and EXTREME. It is also represented by a comfort icon that corresponds to the different UV levels. The main unit records daily and weekly maximum of the UV intensity. Values may be displayed in MED/h or UVI. It also displays the remote UV sensor battery status. 6 To access UV mode from the main unit press UP or DOWN until the UV icon on the display will flash. From the handheld remote control: Press . Viewing UV Statistics In UV Mode press the MEMORY button viewing either current UV intensity, daily Maximum UV intensity with “DAILY MAX” displayed or weekly Maximum UV intensity with a “WEEKLY MAX” displayed. Resetting the UV Statistics Memory In UV Mode, press and hold MEMORY button to reset all UV statistics. Setting Units for UV Display (MED/h or UVI) In UV Mode, press and hold SET to convert units between MED/h and UVI. Maintenance Changing Batteries The battery status of the remote UV sensor is checked every hour by the main unit. If the low battery indicator in the display section for UV data lights up, replace the batteries in the remote UV sensor. When the batteries are properly installed, the remote UV sensor will resume sending signals to the main unit. To enforce an immediate remote signals search, press and hold DOWN button on the main unit. Cleaning The outer casing of the remote UV sensor can be cleaned with a damp cloth. Small parts can be cleaned with a cotton tip or pipe-cleaner. Never use any abrasive cleaning agents and solvents. Do not immerse units with electronic parts in water or under running water. 7 Troubleshooting Q: “The display shows dashes “---” for UV readings” A: The display will show “- - -” when the wireless connection to remote UV sensor is lost for 30 minutes. Check and/or replace the batteries in UV sensor. Then press and hold DOWN button on the main unit TE923DW or handheld remote control TS607 to enforce a search for the remote signal. If this does not work, check the wireless transmission path from the remote UV sensor to the main unit and change its locations if necessary. Although wireless signals can pass through solid objects and walls, the remote UV sensor should ideally be within the line of sight of the main unit. The following may be the cause of reception problems: • The remote UV sensor and a main unit are too far from each other. • The signal shielding ma...

Otros modelos de este manual:
Estación meteorológica - TS704 (300.33 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría