Resumen del manual


Racks Dish 19-% x 19-% 2 2 2 Combination 2 2 2 Shipping Weight Approximate basic model 400 400 400 Electrical Rating Approximate Model Volts Phase Total Load Amps 150 208V or 220V 1 16 150B 208V 1 65 150B 220V 1 68 150PRB 208V 1 65 150PRB 220V 1 68 150B 208V 3 38 150B 220V 3 40 150PRB 208V 3 38 150PRB 220V 3 40 Specifications subject to change without notice. 4 GENERAL INSTRUCTIONS (INSTALLATION/DIMENSIONS) FOR 150B, PRB SERIES NOTE: Read the following instructions carefully. Proper installation of your Jackson Dishwasher will assure proper machine operation. 1. Open side doors, the front door (hook open) and remove dish, cup, and glass racks, and set to one side for later use. Remove the tape holding the overflow strainer, the pump intake strainer, the wash head assembly and the rinse head that are inside the machine. 2. Cut straps holding machine to base of crate, ease machine onto floor and slide into place of installation. 3. Connect drain to bottom of machine (IV2" IPS female fitting on bottom of wash sump) with proper slope to conform with local and/or national codes. Drain is a gravity feed system from machine. 4. The incoming water line to the unit must be */*" with the capacity to supply 10.5 gallons per minute with a flow rate of 20 PSI. The temperature at the unit must be 140° F. This connection is just before the Y-strainer. Connect to conform with local and/or national codes (STANDARDS). 5. Electrical connections should be made through hole in bottom of power box to terminal board inside (to the right lower side of control box). This terminal board is accessible by removing the lower cover plate on control box. The terminals are marked L1, L2 (requiring 208—230V, single phase), or L1, L2, L3 (requiring 208—230V, three phase). There is a grounding lug inside of the power box on the bottom left. Be sure all connections made are tightened properly. Refer to data plate for Voltage and Amperage totals. 6. Install the proper circuit breaker, wire, and conduit size to conform with local and/or national codes. Refer to data plate for electrical loads. 7. DO NOT APPLY POWER UNTIL STEP 10. 8. Insert pump intake strainer and overflow strainer, then close door. 9. Turn on hand valve controlling water supply to machine; check for any leaks in plumbing and connections. 10. To energize electrically, proceed as follows: a. Turn on customer's circuit breaker controlling machine. b. Check voltage at incoming terminal L1, L2, and L3 (if applicable). It should match data plate voltage. Voltage at L1 and L2 should be checked to ground individually to ensure that a high (or wild) leg is not connected to L1 or L2. (Voltage exceeding 150V to ground would indicate high leg). c. If voltages are in required range, turn on 15 amp circuit breaker on side of power box. The 15 amp circuit breaker protects and controls the motors and control circuit only; it is not meant to protect or control the rinse heaters. d. insert a rack into the machine and close all doors. e. Turn on the power switch; this supplies voltage to the operating controls. Then . depress the rinse/fill switch. The unit will automatically fill the wash tub with water to a specific level. f. Open the front door and check the water level. It should be V* ” below overflow level. If not, check the incoming water line making sure that the solenoid valve fully opens and closes as the switch is turned on and off. g. If the water is at the proper level, close the front door and observe the temperature gauges; the rinse temperature should rise to the specified level of 180° within five minutes if the incoming water temperature is 140® to the booster tank. h. The wash heater will take longer to reach 150®F, as the element is designed for maintaining temperature, not heating. i. Turn the manual wash switch on with the door closed. You should hear the water being pumped as it strikes the top of the machine. Turn off the manual wash switch. j. The unit is now ready to proceed with the washing of dishes in accordance with the operating instructions in this manual and the instruction sticker on the front door of the dishwasher. 5 WALL 38%” 24’ I I , 18%’* (g LJ TV- J r8"- 1L Zi FRONT VIEW NOTES: A—Drain 1*6*. I.P.S. B—Water Inlet I.P.S. C—Eiectrical Connection 0—Standard Wall Clearance W/Oishtabie 3 V' r ioy2' ©¡© V«*«« V I TOP VIEW ® — 100 SERIES CORNER MODEL V r 150 SERIES TABLE CONNECTION INSTALLATION of DETERGENT DISPENSER and/or RINSE INJECTION EQUIPMENT Located in the back of the control box on top of the machine is a knockout which is provided for a Vi" conduit fitting. Terminals DT-1 and DT-2 provide line voltage (208/220VAC) during the machine cycle. Equipment connected must not exceed 0.5KVA. Connections MUST be made with suitable materials and MUST be in accordance with all applicable codes. ALL ELECTRICAL CONNECTIONS MUST BE MADE BY QUALIFIED PERSONNEL Two fuses are needed to meet the r...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría