Iniciar sesión:
Votos - 3, Puntuación media: 3.7 ( )

Manual de usuario Jackson, modelo AJ-44TG

Fabricar: Jackson
Tamaño del archivo: 6.45 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Hard water makes dishmachines work harder and decreases efficiency. Again, it is important to remind operators that trying to perform corrective maintenance on the dishmachine could lead to larger problems or even cause harm to the operator. If a problem is discovered; secure the dishmachine using proper shut down procedures as listed in this manual and contact Jackson. Some problems, however, may having nothing to do with the machine itself and no amount of preventative maintenance is going to help. A common problem has to do with temperatures being too low. Verify that the water temperatures coming to your dishmachine match the requirements listed on the machine data plate. There can be a variety of reasons why your water temperature could be too low and you should discuss it with Jackson to determine what can be done. By following the operating and cleaning instructions in this manual, you should get the most efficient results from your machine. As a reminder, here are some steps to take to ensure that you are using the dishmachine the way it was designed to work: 1. Ensure that the water temperatures match those listed on the machine data plate. 2. Ensure that all strainers are in place before operating the machine. 3. Ensure that all wash and/or rinse arms are secure in the machine before operating. 4. Ensure that drains are closed/sealed before operating. 5. Remove as much soil from dishes by hand as possible before loading into racks. 6. Do not overfill racks. 7. Ensure that glasses are placed upside down in the rack. 8. Ensure that all chemicals being injected to machine have been verified as being at the correct concentrations. 9. Clean out the machine at the end of every workday as per the instructions in the manual. 10. Always contact Jackson whenever a serious problem arises. 11. Follow all safety procedures, whether listed in this manual or put forth by local, state or national codes/regulations. AJ-44T Series Technical Manual 7610-003-07-21 Issued: 03-21-2006 Revised: N/A 37 SECTION 3: PREVENTATIVE MAINTENANCE LUBRICATION CHART FOR DRIVE GEAR Note: The maintenance procedures detailed here are manufacturer’s instructions for the WINSMITH brand of gear reducer that is installed on the rack conveyors covered in this manual. Ambient Temperature -30 - 15°F 16 - 50°F 51 - 95°F 51 - 95°F 96 - 131°F 96 - 131°F Final Stage Worm Speed1 up to 2000 FPM up to 2000 FPM up to 450 FPM above 450 FPM up to 450 FPM above 450 FPM ISO Viscosity Grade 220 460 680 460 680 460 AGMA Lubricant No. 5S #7 Compounded #8 Compounded #7 Compounded 8S 7S Mobil SHC 630 600W Super Extra Hecla Super 600W Super SHC 636 SHC 634 Cylinder Cylinder American Lubricants SHC-90W AGMA #7 Gear Oil AGMA #8 Gear Oil AGMA #7 Gear Oil N/A N/A Castrol Tribol 800/220 Tribol 1105-7C Tribol 1105-8C Tribol 1105-7C Tribol 800/680 Tribol 800/460 Chevron Tegra 220 Cylinder Oil W460 Cylinder Oil W680 Cylinder Oil W460 Tegra 680 Tegra 460 Conoco Syncon R & O Inca Oil 460 Inca Oil 680 Inca Oil 460 N/A Syncon R & O 220 460 Exxon (Esso) Teresstic SHP220 Spartan EP 460 Spartan EP 680 Spartan EP 460 Teresstic SHP 680 Teresstic SHP 460 Fiske Brothers SPO-MG SPO-277 SPO-288 SPO-277 N/A N/A Shell Omala RL 220 Valvata J 460 Valvata J 680 Valvata J 460 Omala RL 680 Omala RL 460 Texaco Pinnacle 220 Vanguard 460 Vanguard 680 Vanguard 460 Pinnacle 680 Pinnacle 460 (1) The sliding velocity in feet per minute (FPM) for standard ratios is determined by multiplying the speed of the worm in RPM by the factor from the table below. For selecting proper lubricant, use the speed of the worm in the final stage (input RPM divided by the first stage ratio). AJ-44T Series Technical Manual 7610-003-07-21 Issued: 03-21-2006 Revised: N/A 38 SECTION 3: PREVENTATIVE MAINTENANCE DRIVE MOTOR GEAR REDUCER PREVENTATIVE MAINTENANCE Note: The maintenance procedures detailed here are manufacturer’s instructions for the WINSMITH brand of gear reducer that is installed on the rack conveyors covered in this manual. Lubrication & Maintenance: Factory filling - WINSMITH speed reducers are oil filled at the factory to the proper level for the standard mounting position that you will find it in on the unit. The oil level should be checked and adjusted (if necessary) prior to operation, using the oil level plug provided and while the unit is oriented in its operating position. Ambient temperature - If the operating ambient temperature is other than 51 - 95°F, then refer to the lubrication chart and refill the unit with the correct grade based on actual ambient temperature and operating speed. See “Oil changing” below for additional information. Oil changing - When changing the oil for any reason, it should be remembered that oils of various types may not be compatible. Therefore, when changing to a different oil, it is recommended that the housing be completely drained and thoroughly flushed with a light flushing oil prior to refilling with the appropriate lubricant. The oil level should be rechec...

Otros modelos de este manual:
Lavavajillas - AJ-44TE (6.45 mb)
Lavavajillas - AJ-44TS (6.45 mb)
Lavavajillas - AJ-66TE (6.45 mb)
Lavavajillas - AJ-66TG (6.45 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría