|
Resumen del manual
A fused disconnect switch or circuit breaker must be installed in the electrical service line supplying this dishwasher and should meet the requirements of your local electrical code. The incoming power supply connections should be made to the terminal block in the control box and a ground lead should be connected to the grounding lug in the control box if grounding is not provided by the conduit used. When equipped with single point electrical connection option for both the dishwasher and electric booster, one incoming electric supply line should be connected to the terminal block in the control box and a ground lead should be connected to the grounding lug if grounding is not provided by the conduit used. When equipped with the circuit breaker option . . . the incoming electrical supply or supplies should be connected to the terminal block in the circuit breaker box on top of the dishwasher. If the electric booster option is supplied, a separate connection may or may not be required, depending upon whether or not single point electrical connection option is present. A ground lead should be connected to the grounding lug if grounding is not provided by the conduit used. When equipped with both single point electrical connection and circuit breaker options . . . the incoming electric supply should be connected to the terminal block in the circuit breaker box on top of the machine. A ground lead should be connected to the grounding lug if grounding is not provided by the conduit used. Check Rotation (Three-Phase Machines Only) Three-phase motors must rotate in the direction of the arrow on the pump housing. In order to check rotation, the motor fan cover must be removed. Close the machine doors and press the power switch to ON. When the machine is completely filled, place the cycle switch (located on the side of the control box) on MANUAL and place the WASH / RINSE switch (located under the cycle switch) on WASH. The motor fan must rotate in the direction of the arrow on the pump housing. If the rotation is incorrect, DISCONNECT ELECTRICAL POWER SUPPLY and interchange any two of the incoming power supply leads. Reconnect the power supply and verify correct rotation. Replace the motor fan cover. – 10 – Electric Booster Water Heater Option NOTE: Electric Booster electrical connection will be separate from the dishwasher electrical connection unless single point electrical connection is supplied. If circuit breaker option is provided, the electric supply or supplies are connected to the circuit breaker box on top of the dishwasher. Refer to Electrical Data, page 12. Before making electrical connection, test the electrical service to assure that it agrees with the specifications on the Electric Booster data plate (Fig. 6). Also, refer to the wiring diagram attached inside the cover of the Electric Booster. A fused disconnect switch or circuit breaker (if not supplied) must be installed in the electrical service line supplying this booster and should meet the requirements of your local electrical code. If the booster electrical connections are separate, they are made to the contactor in the booster. If grounding is not provided by the conduit used, connect the ground lead to the grounding lug provided (Fig. 6). Fig. 6 OPTIONAL EQUIPMENT CONTROL CONNECTIONS NOTE: The 7.8" plugged holes in the side of the control box are for detergent and chloritizer / rinse feeder connections only. If detergent and chloritizer / rinse feeder electrical connections are required, remove the plug buttons(s) and connect through the hole(s) provided. Detergent Dispenser Maximum rating for detergent dispenser connected to DPS1 and DPS2 is 1.5 Amps at line voltage. Rinse Aid Dispenser Maximum rating for rinse aid dispenser connected to RPS1 and RPS2 is 1.5 Amps at line voltage. Vent Fan Control The maximum rating for a vent fan control relay connected to terminals 4 and 6 is either 30 Amps at 120 Volts (1.5 HP) or 25 Amps at 277 Volts (3.0 HP). The vent fan control relay provides switch contacts only and does not provide the power supply for the vent fan motor. When the dishwasher is connected to the vent fan, the vent fan is switched on when the dishwasher is on, and off when the dishwasher is off. Hobart Infrared Booster Gas Water Heater The maximum rating for connecting a Hobart Model IB57 Dishwasher Activated infrared gas booster water heater to BSTR1 and BSTR2 is 0.5 Amp at 24 Volts. If a Stand Alone Booster Heater is used, no electrical connection to the dishwasher is allowed. Refer to the Infrared Booster Gas Water Heater Manual for additional installation details. – 11 – ELECTRICAL DATA ATADLACIRTCELEATADLACIRTCELEATADLACIRTCEEEELATADLACIRTCELATADLACIRTCEL Model ledoMledoMleMMMdoledoledo Volts / Hz / Ph hP/zH/stloVhP/zH/stloVhP/zH/stVVVlohP/zH/stlohP/zH/stlo Tank Heat taeHknaTtaeHknaTtaeHkTTTnataeHknataeHkna Minimum Circuit Ampacity yticapmAtiucriCmuminiMyticapmAtiucriCmuminiMyticapmAtiucriCmumiMMMniyticapmAtiucriCmuminiyticapmAt...
Otros modelos de este manual:Lavavajillas - AM14 ML-32614 (1 mb)