|
Resumen del manual
State the nature of the fault, where the Alarm was purchased and the date of purchase. 12. FIVE YEAR GUARANTEE Ei Electronics guarantees this Alarm (excluding battery in the Ei141/144/146 models) for five years from date of purchase against any defects that are due to faulty materials or workmanship. This guarantee only applies to normal conditions of use and service, and does not include damage resulting from accident, neglect, misuse, unauthorised dismantling, or contamination howsoever caused. This guarantee excludes incidental and consequential damage. If this Alarm should become defective within the guarantee period, it must be returned to Ei Electronics, with proof of purchase, carefully packaged, with the problem clearly stated. (see “Getting Your Alarm Serviced”) We shall at our discretion repair or replace the faulty unit. Do not interfere with the Alarm or attempt to tamper with it. This will invalidate the guarantee, but more importantly may expose the user to shock or fire hazards. This guarantee is in addition to your statutory rights as a consumer. 10 B16009-R0-160RC SERIES-U&C 17/1/07 11:13 AM Page 10 The crossed out wheelie bin symbol that is on your product indicates that this product should not be disposed of via the normal household waste stream. Proper disposal will prevent possible harm to the environment or to human health. When disposing of this product please separate it from other waste streams to ensure that it can be recycled in an environmentally sound manner. For more details on collection and proper disposal, please contact your local government office or the retailer where you purchased this product. 13. TROUBLESHOOTING 1. FREQUENT NUISANCE ALARMS OCCUR: (1) Close kitchen / bathroom door when in use. (2) Ensure that the alarm is sited at least 6m away from sources of fumes. (3) Contamination from insects, paint or paint fumes may have occurred. Clean the alarm - see “CLEANING YOUR ALARM” section on page 6. (4) If the problem persists, resiting of the unit should be considered. 2. ALARM SOUNDS FOR NO APPARENT REASON: (1) Identify the alarm source. On interconnected units, the red light on the cover will flash rapidly only on the unit which is the source of the alarm. If an optional Ei1529RC Control Switch is installed, press Locate when system is sounding to identify source of alarm. (2) Check for fumes, steam etc. from the kitchen or bathroom. Paint and other fumes can cause nuisance alarms. (3) Press the test/hush button to silence the Smoke/Heat Alarm for 10 minutes. (4) If alarm does not stop, switch off mains and remove unit see “ALARM REMOVAL” section on page 2. (Only remove the alarm with the red light flashing, the others are probably satisfactory). 3. LOW BATTERY & OTHER BEEPS: (On Ei141/144/146 only) If the battery is correctly connected and the unit has beeped for over 20 minutes the battery is probably depleted. Obtain a new battery, disconnect the mains, then remove the alarm and replace the depleted battery. (On Ei161RC/164RC/166RC only) Check the green mains power light is on. If not, check fuse, circuit breakers and wiring connections. If the green light is off, the Lithium cells will deplete after some months without mains and will need to be recharged. If turning on the mains fails to stop the beeps, a fault may exist. Switch off mains and remove the unit - see “ALARM REMOVAL” section on page 2. (All Alarms) (1) If the green mains light is on and replacing battery, recharging Lithium cells or cleaning unit has not stopped the 11 B16009-R0-160RC SERIES-U&C 17/1/07 11:13 AM Page 11 13. TROUBLESHOOTING (CONTINUED) beeps, a fault may exist. Disconnect the mains first and replace the unit - see “ALARM REMOVAL” section on page 2. (2) Ionisation Smoke Alarms (Ei141/161RC) and Heat Alarms (Ei144/164RC) give two beeps 10 minutes after the test/hush button is pressed. (3) If an Optical unit (Ei146/166RC) beeps without the red light flashing at the same time, the chamber is defective. Clean the chamber. 4. INTERCONNECTED ALARMS DO NOT ALL SOUND: (1) Hold test button for 10 seconds after first alarm has sounded to ensure signal is transmitted to all units. (2) One or more of the connections may not be correctly connected. We recommend you consult a qualified electrician. Aico Ltd. Mile End Business Park, Maesbury Rd, Oswestry, Shropshire SY10 8NN, U.K. Tel: 0870 758 4000 Ei Electronics. Shannon, Co Clare, Ireland. Tel: 061 471277 INDEX 1. REGULAR CHECKS 1 2. ALARM REMOVAL 2 3. IMPORTANT INFORMATION 3 4. CHANGING THE BATTERY 4 5. TESTING & MAINTAINING YOUR ALARM 4 6. CLEANING YOUR ALARM 6 7. NUISANCE ALARMS 7 8. IMPORTANT SAFEGUARDS 8 9. PLANNING YOUR ESCAPE ROUTE 8 10. ALARM CONTROL 10 11. GETTING YOUR ALARM SERVICED 10 12. 5 YEAR GUARANTEE 10 13. TROUBLESHOOTING 11 12 B16009-R0-160RC SERIES-U&C 17/1/07 11:13 AM Page 12 230V~ SMOKE & HEAT ALARMS ALKALINE PRIMARY BATTERY BACK-UP Ei141 -Ionisation Ei144 -Heat Ei146 -Optical RECHARGEABLE ...
Otros modelos de este manual:Detector de incendios - B16009-R0-160RC Series (272.86 kb)
Detector de incendios - Ei166RC (272.86 kb)