Iniciar sesión:
Votos - 4, Puntuación media: 4.5 ( )

Manual de usuario Linear, modelo DXS-80

Fabricar: Linear
Tamaño del archivo: 103.44 kb
Nombre del archivo: 2ab556e0-b593-4b58-b27b-ccf6f80c6f6c.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


It is compatible with Linear’s wireless DXS Format Security Systems, Personal Emergency Reporting Systems (PERS), , and other stand-alone receivers. The DXS-80 provides a warning to alert against both the acute and chronic effects of carbon monoxide (CO) poisoning. When carbon monoxide is detected, , the alarm sounds a loud local alarm. The built-in transmitter sends a digitally coded wireless signal to its companion receiver every 20 seconds until the air has cleared and the detector is restored. The local alarm can be silenced once by pressing the test/ reset button. The transmitter will continue to send an alarm signal every 20 seconds. After 7 minutes, the alarm will sound again if there is still an unsafe carbon monoxide concentration level. The reset function can be used only once for each alarm occurrence. No field coding is required because the DXS-80 is factory set to a unique code; one of over a million possible codes. Model DXS-80 (SST00116) Carbon Monoxide Alarm Also available as a kit: DX-COKIT (SSA00020) Kit contains one DXR-702 receiver with a DXS-80 already learned into the receiver Model DXR-702 (SNR00149) 2-Channel Receiver The DXS-80 is powered by one 3-volt lithium battery.The battery is supplied and can power the unit for up to the six year life of the detector. If the battery voltage drops below a preset level the alarm will sound a low battery chirp every 45 seconds and a low battery signal will be sent to the receiver. At about 6 years, the carbon monoxide A detector element will reach the end of its serviceable life.The self-supervising detector will signal a permanent trouble condition, indicating time for replacement. SPECIFICATIONS REGULATORY LISTINGS: UL2034 DETECTION METHODS: Electrochemical TIME TO ALARM PER UL 2034: Carbon Monoxide Concentration Level Minimum Time to Alarm Maximum Time to Alarm 50 ppm +/-5 ppm 30 days Indefinite 70 ppm +/-5 ppm 60 min 240 min 150 ppm +/-5 ppm 10 min 50 min 400 ppm +/-5 ppm 4 min 15 min AUDIBLE OUTPUT: 85 dBA/10' OPERATING TEMP. RANGE: 32.-100. F POWER: 3-Volt battery (Lithium Type 123A) (UL tested for greater than 1 year service life) CURRENT: 7 mA alarm average, 15 .A standby FREQUENCY: 315 MHz NUMBER OF CODES: One of 1,048,576 possible codes DIMENSIONS: 5.3" diameter, 2.0"h COMPATIBLE RECEIVERS†: PERS-3600 PERS-2400A DXSR-1504 DXSR-1508 DVS-1200 DXR-702 DUAL-824 DVS-2400 NOTE: The DX-COKIT is not for use † The DXS-80 is currently UL Listed for use with the Linear PERS Consoles only. It has not in UL Listed applications been tested by UL with other compatible Linear receivers. DXS-80 DXR-702 Security Alarm Panel DX-COKIT The DX-COKIT is an excellent way to add CO protection to new or existing security alarm panels Security Alarm Panel Requirement: Available input(s) which can accept a dry N.C. or N.O. contact DX-COKIT • Includes one DXS-80 CO Detector and one Linear DXR-702 Receiver, with the DXS-80 already learned into the receiver • Interconnects to any Security Alarm Panel that can accept a dry N.C. or N.O. contact for a zone input • Perfect for installations that require one CO detector For applications requiring more than one CO detector, Linear recommends and offers the following product solutions: NOTE: The DX-COKIT is not for use in UL Listed applications DXS-80 DXR-702 Security Alarm Panel DX-COKIT The DX-COKIT is an excellent way to add CO protection to new or existing security alarm panels Security Alarm Panel Requirement: Available input(s) which can accept a dry N.C. or N.O. contact DX-COKIT • Includes one DXS-80 CO Detector and one Linear DXR-702 Receiver, with the DXS-80 already learned into the receiver • Interconnects to any Security Alarm Panel that can accept a dry N.C. or N.O. contact for a zone input • Perfect for installations that require one CO detector For applications requiring more than one CO detector, Linear recommends and offers the following product solutions: NOTE: The DX-COKIT is not for use in UL Listed applications Number of CO Detectors 1 1 to 4 1 to 8 Linear Receiver DXR-702 DXSR-1504 DXSR-1508 Notes Use the Linear DX-COKIT Purchase the required number of DXS-80 Detectors Purchase the required number of DXS-80 Detectors NOTE: When multiple CO detectors are required for an application, Linear recommends that each CO detector be assigned to its own receiver channel to assure proper device supervision and reporting. USA & Canada (800) 421-1587 & (800) 392-0123 (760) 438-7000 - Toll Free FAX (800) 468-1340 Copyright © 2008 Linear LLC Printed in China 228209 AX2 ...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría