Iniciar sesión:
Votos - 3, Puntuación media: 3 ( )

Manual de usuario Honeywell, modelo NOTIFIER IFS-2600

Fabricar: Honeywell
Tamaño del archivo: 865.9 kb
Nombre del archivo: ifs-2600_install_manual_v3_01.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


The "ISOLATE" button will need to be depressed again to re-enter isolate mode. If a correct entry is made, the zone is immediately isolated. If the zone is already in alarm, all of its alarm outputs are isolated and indicators remain visible. If the "ALL" function is performed, all zones will be isolated, regardless of their previous state. Performing the "ALL" function for a second time will de-isolate all zones. RESET RESET # ENTER The reset function momentarily disconnects power, and resets all alarm parameters for the zone(s) being reset. This returns the zone back to its "normal" state. ‘#’ in the above key sequence is the zone number. If only one zone is to be reset, type in the zone number. Alternatively the "ALL" button can be used to simultaneously reset all zones. To perform a reset on a particular zone or on all zones: 1. Press the "RESET" button. The buzzer will give 2 short beeps to indicate that reset mode has been entered. 2. The LCD display will read "ALARM RESET MODE, ENTER ZONE NO". 3. Enter the zone number ("#") 1-64 or “all”. 4. Press "ENTER". A long beep will signify an incorrect entry and will revert back to normal operating mode. The "RESET" button will need to be depressed again to re-enter reset mode. If a correct entry is made, resetting of the zone begins immediately. Any alarm indication will be removed immediately; also resetting the zone(s) programmed outputs. P/N 10069 ECN08-0066 IFS-2600 Installation & Programming Manual Page 27 PROGRAMMING GLOBAL OPTIONS ANCILLARY TRIP 1 LATCHING NORMALLY DE-ENERGISED 2 NON-LATCHING NORMALLY DE-ENERGISED 3 LATCHING NORMALLY ENERGISED 4 NON-LATCHING NORMALLY ENERGISED ALARM VERIFICATION 1 DISABLED 2 2 MINUTES 3 3 MINUTES 4 4 MINUTES 5 5 MINUTES TIME (DD) / (MM) / (YY) (HH) : (MM) ZONE OPTIONS DESCRIPTION INPUT DELAY 1 Standard Latching 2 seconds 2 Standard Latching 2 seconds with AVF 3 Non Latching 2 seconds 4 Non Latching 20 seconds 5 Time Delay 10 seconds 6 Time Delay 20 seconds 7 Time Delay 30 seconds 8 Time Delay 40 seconds 9 Time Delay 50 seconds 10 Time Delay 60 seconds Type Output Description 1 Indicate Only 2 Indicate, Bell 3 Indicate, Bell, General Alarm 4 Indicate, Bell, General Alarm, Ancillary 5 Indicate, Bell, General Alarm, Ancillary, Brigade Relay #1 6 Indicate, Bell, General Alarm, Ancillary Brigade Relay #2 7 Indicate, Bell, General Alarm, Ancillary, Brigade Relay #1, & Brigade Relay #2 P/N 10069 ECN08-0066 Page 28 IFS-2600 Installation & Programming Manual P/N 10069 ECN08-0066 OUTPUT RELAY OPTIONS Optional Relays can be programmed to simulate: - . Isolate Relay . ACF Output . Brigade Relay #1 . Brigade Relay #2 . Fault Relay . Mains Fail Relay . General Alarm Relay . Bell Output . Door Holder Relay . Door Switch . Reset Or Can Be Used To: . "MAP AND" Up to 5 Zones in Alarm . "MAP OR" Up to 5 Zones in Alarm . “MAP FAULT” Up to 5 Zones in Fault . “MAP ISOLATE” Up to 5 Zones in Isolate . “MAP ISO/FAULT” Up to 5 Zones in Isolate/Fault DEFAULT SETTINGS ACF OUTPUT NON-LATCHING, NORMALLY DE-ENERGISED ALARM VERIFICATION (AVF) 3 MINUTES TIME 1/1/11 11:11 ZONE TYPES STANDARD LATCH 2S ZONE OUTPUT CONFIG I-B-G-A-BR1 & BR2 RELAY MAPPING MAP -OR-, MAPPING = 1 TO 1 IE: RELAY 1 = ZONE 1, RELAY 2 = ZONE 2............. The 2600 PANEL is self-configuring on power-up therefore it is not necessary to program the number of relay boards. Zone expansion boards fitted must have the correct jumper selected. IFS-2600 Installation & Programming Manual Page 29 P/N 10069 ECN08-0066 PROGRAM MODE Press the following buttons in order shown to enter programming mode. PREVIOUS > NEXT > SELECT > EXIT > ENTER PROGRAMMING MODE The liquid crystal display will display all messages and prompts required to program the 2600. ONLY the "PREVIOUS","NEXT","SELECT","EXIT" AND "ENTER" keys are used in programming mode. All other keys will give an error beep and are ignored. Alarm detection is not affected during the programming function but you must exit programming mode if any other panel functions are to be performed including acknowledge and reset of alarms. Note: Refer to appendices for detailed explanation of functions PROGRAMMING HIERARCHY EXIT SAVE CHANGES YES NO ZONES RELAY GLOBAL PRINT ZONES TYPE OUTPUT STD LATCHING INDICATE STANDARD LATCHING AVF I BELL NON LATCH IB GENERAL NON LATCH 20S IBG ACF OUT TIME DELAY 10S IBGA BRIGADE 1 TIME DELAY 20S IBGA BRIGADE 2 TIME DELAY 30S IBGA BRIGADE 1 & 2 TIME DELAY 40S TIME DELAY 50S TIME DELAY 60S Page 30 IFS-2600 Installation & Programming Manual RELAYS TYPE MAPPING ISOLATE RELAY ANCILLARY OUTPUT (ACF) BRIGADE RELAY #1 BRIGADE RELAY #2 FAULT RELAY MAINS FAIL RELAY GENERAL ALARM RELAY BELL OUTPUT DOOR HOLDER RELAY MAP -AND (00)(00)(00)(00)(00) MAP -OR (00)(00)(00)(00)(00) MAP -FAULT (00)(00)(00)(00)(00) MAP – ISOLATE (00)(00)(00)(00)(00) MAP – ISOLATE / FAULT (00)(00)(00)(00)(00) DOOR SWITCH RESET GLOBAL ACF AVF RELAY TIME NON-LATCHING ND DISABLED MAP RELAY (XX) >>> (DD) / (MM) / (YY) LATCHING ND 2 MINUTES FROM ZONE XX (HH) :...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría