To order additional LABath CLEANTM, call GenesisBPS, LLC at 866-712-5663. 5.7 Fill the bath. The maximum water level should be approximately two inches from the top of the water bath. This level will ensure that the water level will be at the slotted line on the unit when the bath is repositioned. DON'T OVERFILL THE BATH. Add 2 ml of LABath CLEANTM each time water is changed. DON'T USE BLEACH OR HARSH CLEANERS as this may scratch and discolor bath. 5.8 To replace bath: GENTLY place the bath onto the ROCKER PIN, ensure the pin head is located in the slot of the bath. Ensure that the center of bath is positioned onto the white roller on the base plate. Hold the handle firmly on the front of the control panel. Release the clamp knob by turning it counterclockwise. Lower the unit slowly into the water. 11 6. CONTROL PANEL AND INDICATORS GENESIS 2002TM CONTROL PANEL 12 GENESIS 2006TM CONTROL PANEL 13 CONTROL KEYS POWER .......... This key turns the unit on and off when the POWER SWITCH on the left panel is turned ON. The POWER SWITCH on the left panel is a master on/off switch to remove electrical power completely from all circuits in the unit. SET TEMP ..... With this key switch you can adjust water temperature within the range of ambient to + 56 oC. Numeric keys must be pressed within 5 seconds of each other, otherwise display returns to the original figure. HEAT .............. This key turns the heater and water pump on and off. An indicator to its right indicates its status. Even if this key is turned on, the HEATING indicator light shuts off when water temperature reaches set temperature. ROCK ..............This key makes the tub rock. An indicator to its right indicates its status. Pressing this key at any time will stop the rocking motion. NUMERIC KEYS (0 - 9) ... These keys are used to enter a new value when the SET TEMP key or START/CHANGE key is pressed first. START/CHANGE ....This key has dual function. When this key is pressed, the timer display starts countdown from the default or preset timing, 14 minutes for the GENESIS 2002TM and 18 minutes for GENESIS 2006 TM. If a numeric key entry is made within 5 seconds, a new time is set and displayed, and counts down. 14 INDICATORS HEATING ....... This red indicator is lit when the heating element is actually drawing current from the circuit and heating the water. When it reaches set temperature, the heating indicator light shuts off. FAULT ............ If the water temperature exceeds 58 °C, an alarm will sound and the red fault light will be illuminated. This may indicate a unit malfunction. ADD WATER .... This red indicator will light if there is insufficient water in the bath. The unit will not operate. Add water to correct this condition. This indicator will light also when the shroud unit is lifted in up position. 7. TROUBLESHOOTING GUIDE PROBLEM and ACTION 1) The indicator lights and displays do not come on when the POWER key is pressed. • Check the POWER SWITCH on the left-hand side. • Check the outlet for 110/120 VAC 60 Hz. • Check the fuse in the unit. Replace the fuse if necessary. • Ensure that the POWER key is pressed for at least one second. • Check that there is sufficient water in the bath and that the ADD WATER light is off. • Check that the FAULT light is off. 15 2) The ADD WATER light is on and there is sufficient water in the bath. • With the unit unplugged and raised out of the water, check that there is no obstruction around the float switch in the shroud unit. The float should move freely up and down the stem approximately half-inch. 3) The FAULT light is on. • Check the water temperature. If the water temperature is above 58 °C, the FAULT light will light and the unit will not be operable. • If this temperature is reached, it may indicate a unit malfunction. Contact GenesisBPS, LLC for further assistance. 4) Unit does not heat. HEATING light is on but actual water temperature is not increasing. • Remove rear cover and check the heating element for continuity. Replace if necessary. This maintenance should only be performed by a trained technician or GenesisBPS, LLC. Contact it or your Biomedical Department. 5) Unit does not rock • Check that the ADD WATER or FAULT lights are not illuminated. 6) Bath moves to side when rocking or the rocking motion is not smooth. • Ensure that the bath is positioned on the white roller. • The unit must be operated on a smooth and level surface. Check the level of the work surface and make adjustments if necessary. 16 7) Pump does not circulate the water. • Debris may be in the pump impeller housing. Raise the shroud unit and lock in the up position. Inspect pump for debris and remove with tweezers or similar instrument. 8) HEATING light is flashing. • This is normal operation. At approximately one degree below the set temperature, the microprocessor begins to reduce the amount of heat generated and the HEATING light begins to flash. 9) Temperature display at WATER TEMP deviates from thermometer readin...
Otros modelos de este manual:Baño - 2002 (218.13 kb)