Resumen del manual


printing width: 4.1 in (104 mm) • Max. paper width: 4.65 in (118 mm) • Max. printing length: 32 in (812 mm) Printing speed • 2–4 inches/second in one-inch units Print mode • Batch mode: Normal printing (single or multi sheets) • Peeling mode: Label peeling off the liner after printing • Cut mode: Cutting and printing by the specified number of sheets (label feeding back enabled) • Tear-off mode: Paper feeding back to the printing start position after cutting Bar code generator One-dimensional bar code: • Code 3 of 9 • UPC-A • UPC-E • Interleaved 2 of 5 • ITF14 • ITF16 • Telepen • Code 128 • EAN-13 (JAN-13) • Codabar (NW-7) • HIBC (Modulus 43-used code 3 of 5) • EAN-8 (JAN-8) • Int 2 of 5 (Modulus 10-used Interleaved 2 of 5) • Plessey • CASE CODE • Code 93 • UPC2DIG ADD • UPC5DIG ADD Two-dimensional bar code: • UPS Maxi Code • PDF-417 • QR Code 6-2 Item Description Standard fonts • Font No. 0–6 system font (alphanumeric and European font) • Font No. 7–8: OCR-A OCR-B • Font No. 9: CG Triumvirate smooth fonts; 6 pt, 8 pt, 10 pt, 12 pt, 14 pt, 18 pt, 24 pt, 30 pt, 36 pt, and 48 pt. Character set in accordance with code page 850 Media sensors • Transparent type sensor: Detects paper gap between labels, tag notch and paper out • Reflective type sensor: Detects black line on back of paper and paper out • Paper top end position (home position) adjustable with software • Label peeling sensor (optional) Paper • Type of paper: Roll or fanfold type (continuous label paper, die-cut label paper, tag paper and continuous ticket paper) • Kinds of paper: Direct-thermal or thermal-transfer paper • Max. paper width: 4.65 in (118 mm) • Min. paper width: 1 in (25.4 mm) • Max. printing length: 32 in (812 mm) • Min. printing length: 0.500 in (12.7 mm) • Max. paper thickness: 0.01 in (0.254 mm) • Min. paper thickness: 0.0025 in (0.063 mm) • Roll paper diam.: max. outer diam.: 4 in (102 mm): Standard 8 in (203 mm): Optional paper core: 1.5–4 in (38–102 mm) • Print density: Adjustable with software Ribbon • Width: Freely set between 1.0–4.5 in (25.4–114 mm) • Length: 1180 ft (360 m), max. • Max. outer diam.: 2.9 in (74 mm) • Paper core inner diam.: 1 in (25.4 mm) ±0.01 in (0.254 mm) 6-3 Item Description Communication interface • Serial: RS-232C • Parallel: Centronics Indications, keys and switches • LEDs: Power and Error • LCD: Displays printer status, error contents, mode switch contents, etc • Control panel keys: Pause, Feed and Stop • Mode switch: Parameter setting for switching between direct-thermal and thermal- transfer, communication etc. • Head up detection switch • Power switch Options By factory: • Auto-cutter unit • Peeler unit • Adjustable sensor unit By user: • 8-in size roll paper holder • PCMCIA memory card Appearance and weight • Height: 9.3 in (235.1 mm) • Width: 9.6 in (245 mm) • Depth: 11.4 in (289.8 mm) • Weight: 11.2 lbs (5.1 kg) Power • Input voltage 120V: -10%+6%, 2.5A, 60Hz (U.S.A., Canada) • Input voltage 220V–240V: -10%+6%, 1.2A, 50/60Hz (Europe) Environment • Operating conditions: Temperature: 5–35°C (41–95°F) Humidity: 30–80% (non-condensing) • Storage: Temperature: -20–60°C (-4–140°F) Humidity: 5–85% • Ventilation: Convective circulation. Air vent be away from wall etc (to prevent fire) • Dust: Free from conductive or corrosive matter 6-4 6.2 Interface The printer is connected to a computer and prints labels according to the commands from the computer. Two methods of interface with a computer are as follows: 6.2.1 Serial interface system configuration Serial interface: RS-232C (standard) Computer RS-232C interface RS-232C interface Printer Serial interface specifications Method Asynchronous serial interface RS-232C Connector DSUB 25-pin Protocol control XON/XOFF and CTS/DTR Receive buffer size 12K bytes Receiving data stops when the receive buffer reaches 2K bytes available and resumes when the receive buffer reaches 4K bytes available Baud rate 300, 600, 1200, 2400, 4800, 9600, 19200, 38400 bps Bit length 7- or 8-bit Stop bit Fixed When printer receives data, stop bit is fixed at 1, and when printer transmits data, stop bit is fixed at 2. But computer can transmit and receive data, regardless of stop bit at 1 or 2 Parity Non 6-5 6.2.2 Parallel interface system configuration Parallel interface: Centronics (standard) Computer Centronics interface Centronics interface Printer Parallel interface specifications Method 8-bit parallel Connector 36-pin unphenol type Synchronous system Strobe pulse Handshaking ACKNLG and BUSY signals Signal level TTL 6-6 6.2.3 RS-232C loopback test After connector wiring as shown in the figure, turn on the test mode. The printer will receive data that has been transmitted by printer itself and the test of receiving and transmitting data will be performed. Fig. RS-232C loopback test 6.2.4 RS-232C protocol (1) X-ON/X-OFF system (see figure) This is a control system in which the data transmitting request signal (X-ON (11H) code) and the data transmitting stop signal (X-OFF (13H) co...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría